Datasheet

DRA1 MP Series
• 10mm Single Channel DIN Rail Mount SSR Assembly
• AC Ratings up to 280 VAC and 4 Amps
• DC Ratings 60 VDC and 3 Amps
• N.O. AC or DC output, N.C. DC Output (-B)
• 3-32VDC control
• Cage style screw terminals for easy connection
• Fits standard 35mm DIN rail
PRODUCT SELECTION
Description
3-32 VDC Control
3-32 VDC Control
3A
3A
4A
DRA1-MP120D3
DRA1-MPDCD3
DRA1-MP240D3
DRA1-MPDCD3-B
DRA1-MP240D4
DRA1-MP120D3
DRA1-MP240D3
DRA1-MP240D4
12-140
400
3
0.02
5
200
86/90
39/36
1.6
24-280
600
3
0.02
5
200
86/90
39/36
1.6
24-280
600
4
0.02
5
200
125/130
78/72
1.6
DRA1-MPDCD3
DRA1-MPDCD3-B
3-60
3
0.02
5
1.5
3-60
3
0.02
5
1.5
DRA1-MPxxxDx
DRA1-MPDCD3
DRA1-MPDCD3-B
3-32 VDC
3.0 VDC
1 .0 VDC
2.6 mAdc
1500 Ohm
8.33
8.33
3-32 VDC
3.0 VDC
1 .0 VDC
2.6 mAdc
1500 Ohm
0.10
0.10
3-32 VDC
1.0 VDC
3 .0 VDC
2.6 mAdc
1500 Ohm
0.10
0.10
AC OUTPUT SPECIFICATIONS (1)
Description
Operating Voltage [VAC]
Transient Overvoltage [Vpk]
Maximum Load Current [Arms] (2)
Minimum Load Current [Arms]
Maximum Off-State Leakage Current @ Rated Voltage [mArms]
Minimum off-state dv/dt @ maximum rated voltage [V/µsec] (3)
Maximum 1 Cycle Surge Current (50/60 Hz) [Apk]
Maximum I²t for fusing (50/60 Hz, 1/2 cycle) [A² sec]
Maximum On-State Voltage Drop @ Rated Current [Vpk]
DC OUTPUT SPECIFICATIONS (1)
Description
Operating Voltage [VDC]
Maximum Load Current [Adc]
Minimum Load Current [Adc]
Maximum Surge Current [Adc]
Maximum On-State Voltage Drop @ Rated Current [Vdc]
INPUT SPECIFICATIONS (1)
Description
Control Voltage Range
Must Turn On Voltage
Must Turn Off Voltage
Typycal Input Current
Nominal Input Impedance
Maximum Turn-On Time [msec]
Maximum Turn-Off Time [msec]
GENERAL SPECIFICATIONS
Description
Dielectric Strength, Input/Output/Base (50/60Hz)
Minimum Insulation Resistance (@ 500 VDC)
Maximum Capacitance, Input/Output
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Weight (typical)
Encapsulation
GENERAL NOTES
1) All parameters at 25°C unless otherwise specified.
2) See derating chart on page 3
3) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
Parameters
4000 VRMS
109 Ohms
8 pF
-40 to 80°C
-40 to 125 °C
0.08 lb (36.4g)
Themally Conductive Epoxy
MECHANICAL SPECIFICATIONS
WIRING DIAGRAM
THERMAL DERATE INFORMATION
AGENCY APPROVALS
Designed in accordance with the requirements of IEC 62314
UL E116950 (relay only)
5900 UG (AC Output Relay Only)
LR81689 (AC Output Relay Only)
Rev. 110811
ANNEX - ENVIROMENTAL INFORMATION