Datasheet

EL Series
• Ratings of 5A and 10A @ 3-100 VDC
• UL Recognized, CE and RoHS Compliant
• 5, 12 and 24VDC control
• Mosfet Output
PRODUCT SELECTION
Control Voltage
4-8 VDC
10-14 VDC
21-27 VDC
5A
10A
EL100D5-05
EL100D5-12
EL100D5-24
EL100D10-05
EL100D10-12
EL100D10-24
OUTPUT SPECIFICATIONS (1)(3)
Description
Operating Voltage Range [VDC]
Maximum Load Current [Adc] (2)
Minimum Load Current [mAdc]
Maximum Surge Current Non-Repetitive (10ms) [A]
Maximum Off-State Leakage Current @ Rated Voltage [µAdc]
Maximum On-State Resistance @ Rated Current (Rds-on)
Maximum On-State Voltage Drop @ Rated Current
5A
10A
3-100
5
150
80
100
0.04 Ohm
0.2V
3-100
10
150
100
100
0.01 Ohm
0.1V
EL100Dxx-05
EL100Dxx-12
EL100Dxx-24
4-8 VDC
4.0 VDC
0.5 VDC
13.3 mA
300
1
300
10-14 VDC
10 VDC
1.0 VDC
11.7 mA
940
1
300
21-27 VDC
21 VDC
2 VDC
11.5 mA
2K
1
300
INPUT SPECIFICATIONS (1)
Description
Control Voltage Range
Minimum Turn-On Voltage
Minimum Turn-Off Voltage
Typical Input Current @ nominal turn-on voltage
Nominal Input Impedance [Ohms]
Maximum Turn-On Time [msec]
Maximum Turn-Off Time [µsec]
GENERAL SPECIFICATIONS
Description
Dielectric Strength, Input to Output
Dielectric Strength, Output to Baseplate
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Weight (typical)
Terminals
Parameters
2500 Vrms
2500 Vrms
-30 to 80 °C
-30 to 125 °C
0.5 oz (14.4g)
3/16" input, 1/4" output QC
GENERAL NOTES
1) All parameters at 25°C unless otherwise specified.
2) When mounted to the proper size heat sink (see derating curves)
3) Inductive loads should be diode suppressed to prevent damage to the relay.
WIRING DIAGRAM
MECHANICAL SPECIFICATIONS
THERMAL DERATE INFORMATION
AGENCY APPROVALS
Designed in accordance with the requirements of IEC 62314
Rev. 120811
ANNEX - ENVIROMENTAL INFORMATION