ActiveReports Document

HS201DR Series
• 35 & 38 amp AC output @ 40°C
• Dual Channel output
• 4 to 32 VDC input control voltage
• DIN Rail mounted
• UL, cUL, CE approved SSRs
PRODUCT SELECTION
Description
4-32 VDC Control
35 A
38 A
HS201DR-CC2425W3U
HS201DR-CD4850W4U
HS201DR-CC2425W3U
HS201DR-CD4850W4U
24-280
600
0.1
500
35
0.15
275/300
1.3
380/370
0.5
48-660
1200
0.25
500
38
0.15
710/750
1.7
2520/2320
0.5
OUTPUT SPECIFICATIONS (1)
Description
Operating Voltage (47-63Hz) [Vrms]
Transient Overvoltage [Vpk]
Maximum Off-State Leakage Current @ Rated Voltage [mArms]
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (2)
Maximum Load Current [Arms]
Minimum Load Current [Arms]
Maximum 1 Cycle Surge Current (50/60 Hz) [Apk]
Maximum On-State Voltage Drop @ Rated Current [Vpk]
Maximum I²t for fusing (50/60 Hz, 1/2 cycle) [A² sec]
Minimum Power Factor (with Maximum Load)
INPUT SPECIFICATIONS (1)
Description
Control Voltage Range
Minimum Turn-On Voltage
Minimum Turn-Off Voltage
Maximum Reverse Voltage
Typical Input Current
Nominal Input Impeadance
Maximum Turn-On Time [msec]
Maximum Turn-Off Time [msec]
Parameters
4-32 VDC
4.0 VDC
1.0 VDC
32 VDC
10 mA @ 12 VDC
(3)
1/2 Cycle
1/2 Cycle
GENERAL SPECIFICATIONS
Description
Dielectric Strength, Input/Output/Base (50/60Hz)
Minimum Insulation Resistance (@ 500 V DC)
Maximum Capacitance, Input/Output
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Status Indicator Display
Weight (typical)
Encapsulation
Load Terminals Screw Torque Range
Thermal pad installed
GENERAL NOTES
1) All parameters at 25°C unless otherwise specified.
2) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
3) Input circuitry for DC control version incorporates active current limiter.
NOTE: For more information see Evolution Dual spec sheet.
Parameters
4000 Vrms
109 Ohms
10 pF
-40 to 80˚C
-40 to 125˚C
Yes
1.03 lb (453g)
Themally Conductive Epoxy
18-20 in/lbs (2.0-2.26 Nm)
Yes
MECHANICAL SPECIFICATIONS
THERMAL DERATE INFORMATION
AGENCY APPROVALS
Designed in accordance with the requirements of IEC 62314
Agency approvals are for relay only.
E116950
Rev. 110911
ANNEX - ENVIROMENTAL INFORMATION