DRA4 MCX Series

DRA4 MCX Series
• 54mm Four Channel DIN Rail Mount SSR Assembly
• AC Ratings up to 280 VAC and 5 Amps
• 3-15 and 15-32VDC control
• Cage style screw terminals for easy connection
• Fits standard 35mm DIN rail
• Includes LED Status indicator
PRODUCT SELECTION
Description
3-15 VDC Control
15-32 VDC Control
5A
DRA4-MCX240D5
DRA4-MCXE240D5
OUTPUT SPECIFICATIONS (1)
Description
DRA4-MCX(E)240x5
Operating Voltage [VAC]
Transient Overvoltage [Vpk]
Maximum Load Current [Arms] (2)
Minimum Load Current [Arms]
Maximum Off-State Leakage Current @ Rated Voltage [mArms]
Minimum off-state dv/dt @ maximum rated voltage [V/µsec] (3)
Maximum 1 Cycle Surge Current (50/60 Hz) [Apk]
Maximum I²t for fusing (50/60 Hz, 1/2 cycle) [A² sec]
Maximum On-State Voltage Drop @ Rated Current [Vpk]
12-280
600
5
0.06
0.1
500
239/250
285/260
1.4
INPUT SPECIFICATIONS (1)
Description
Control Voltage Range
Must Turn On Voltage
Must Turn Off Voltage
Typycal Input Current
Nominal Input Impedance
Maximum Turn-On Time [msec]
Maximum Turn-Off Time [µsec]
DRA4-MCX
DRA4-MCXE
3-15 VDC
3.0 VDC
1 .0 VDC
15 mAdc
300 Ohm
1/2 Cycle
1/2 Cycle
15-32 VDC
15.0 VDC
1 .0 VDC
15 mAdc
1500 Ohm
1/2 Cycle
1/2 Cycle
GENERAL SPECIFICATIONS
Description
Dielectric Strength, Input/Output/Base (50/60Hz)
Minimum Insulation Resistance (@ 500 VDC)
Maximum Capacitance, Input/Output
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Weight (typical)
Encapsulation
Parameters
4000 VRMS
109 Ohms
10 pF
-40 to 80°C
-40 to 125 °C
0.32 lb (145.5g)
Themally Conductive Epoxy
GENERAL NOTES
1) All parameters at 25°C unless otherwise specified.
2) See derating chart on page 3
3) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
MECHANICAL SPECIFICATIONS
WIRING DIAGRAM
THERMAL DERATE INFORMATION
AGENCY APPROVALS
Designed in accordance with the requirements of IEC 62314
E116949 (relay only)
Rv. 110811
ANNEX - ENVIROMENTAL INFORMATION