Series 2 • • • • Triac output SSRs; Output rated at 8A @ 20-280 VAC Zero-crossing (resistive loads) output DC control 3/16" fast-on terminals PRODUCT SELECTION Control Voltage 3.5-8 VDC S218 S228 S228C OUTPUT SPECIFICATIONS (1) Description S218 S228 S228C Operating Voltage (47-63Hz) [Vrms] Transient Overvoltage [Vpk] Maximum Off-State Leakage Current @ Rated Voltage [mArms] Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (3) Maximum Load Current [Arms] Minimum Load Current [Arms] Maximum Surge Current (16.6ms) [Apk] Maximum On-State Voltage Drop @ Rated Current [Vpk] Thermal Resistance Junction to Case (Rjc) [°C/W] Maximum I2 t for Fusing (8.3 msec) [A2 sec] Minimum Power Factor (with Maximum Load) 20-140 400 4.0 200 8.0 0.15 120 1.6 1.5 60 40-280 600 4.0 200 8.0 0.15 120 1.6 1.5 60 40-280 600 1.0 200 8.0 0.15 120 1.6 1.5 60 0.5 0.5 0.5 INPUT SPECIFICATIONS (1) Description Control Voltage Range Maximum Turn-On Voltage Minimum Turn-Off Voltage Typical Input Current @ 5 VDC Nominal Input Impedance Maximum Turn-On Time [msec] (4) Maximum Turn-Off Time [msec] (4) DC Control 3.5-8.0 VDC 3.5 VDC 1.0 VDC 18 mA 200 Ohm 1/2 Cycle 1/2 Cycle GENERAL SPECIFICATIONS Description Dielectric Strength, Input/Output/Base (50/60Hz)(2) Minimum Insulation Resistance (@ 500 V DC)(2) Maximum Capacitance, Input/Output Ambient Operating Temperature Range Ambient Storage Temperature Range Weight (typical) Encapsulation GENERAL NOTES 1) All parameters at 25°C and per section unless otherwise specified. 2) Dielectric and insulation resistance are measured between input and output 3) Off-State dv/dt test method per EIA/NARM standard RS-443 Parameters 2500 Vrms 109 Ohm 8.0 pF -30 to 80°C -30 to 125 °C 1.3 oz (40g) Thermally conductive Epoxy MECHANICAL SPECIFICATIONS THERMAL DERATE INFORMATION AGENCY APPROVALS UL E116949 CSA LR81689 Rev. 111810 ANNEX - ENVIROMENTAL INFORMATION