DRA Series Contactors

DRA Series Contactors
PART NUMBER NOMENCLATURE
DC Motor Reversing Contactors
DRA series DC Motor Reversing Contactors utilize Crydom’s advanced solid state DC switching technology to
provide an integrated “H Bridge” type DC switching contactor for DC motor reversing applications. These
ready-to-use contactors feature logic compatible DC input control with status indicator and interlock and
provide a simple and easy to use control solution for DC motor reversing.
For complete specifications, see DRA Series DC Motor Reversing Contactors datasheet at www.crydom.com.
FEATURES
54 mm motor reversing DIN rail mountable contactor package
90 VDC & 180 VDC Operating Voltage
5 to 15 VDC & 15 to 32 VDC Input Control Voltage options available
Convenient FET switches in H-bridge configuration for Motor Reversing applications
Protective Forward/Reverse interlock built-in function
UL ratings for Resistive & Motor loads
LED Status indicator for Input Control Voltage
No heat sink required & cage style screw terminals for easy installation & reliable wire connection
INSTALLATION INSTRUCTIONS
Operational Voltage Range
100: 1-100 VDC
250: 1-250 VDC
Series
DRA
4D
100
Function
4D: H-Bridge
D
Operational Current
6: 6 Amps/¼ HP @ 180 VDC
(250 suffix only)
12: 12 Amps/¼ HP @ 90 VDC
(100 suffix only)
12
Control Voltage
D: 5 VDC
E: 24 VDC
TO REMOVE FROM
DIN RAIL
Please read all installation instructions before using DRA Series DC Motor Reversing Contactors.
Install the contactor on the DIN rail as shown in fig. 1. Vertical mounting operation is recommended.
Wire the contactor to the input control side following the wiring diagram (fig. 3). 24 AWG minimum, 12 AWG
maximum (IEC 0.5-2.5 mm2), choose wire gauge according to load current. Maximum recommended
terminal screw torque input 4.3 lbs in (0.5 Nm).
Wire the contactor to the DC Line side (+ & -) and to the Load side (M1 & M2). 24 AWG minimum, 12 AWG
maximum (IEC 0.5-2.5 mm2), choose wire gauge according to load current. Maximum recommended
terminal screw torque output 4.3 lbs in (0.5 Nm).
If multiple units are installed be sure to follow derating curve (fig. 2).
TO INSTALL ON DIN RAIL
fig. 1 Mounting/Dismounting contactor on DIN rail.
Rev: 050911
WIRING DIAGRAM (C, F)
DERATING CURVE (A,B)
12.0
DRA4D100x12
DRA4D250x6
Load Current (Amps)
10.0
(E)
8.0
6.0
S1
fig. 2 Derating Curve for
DC Motor Reversing Contactor.
4.0
+ -
2.0
S2
F
R
0.0
+
-
(D)
0
10
20
30
40
50
60
Ambient Temperature (°C)
Temp.
40°C
60°C
(A)
(B)
(C)
(D)
(E)
(F)
+
M1
M2
DRA4D100x12
¼ HP 4 FLA @ 90 VDC
¼6 HP 3 FLA @ 90 VDC
DRA4D250x6
¼ HP 2 FLA @ 180 VDC
¼6 HP 1 FLA @ 180 VDC
Unless otherwise noted, all ratings are at 0 mm air gap for adjacent similar parts.
Resistive Load Current rating for DRA4D250x6 is 5.5 A @ 0 mm air gap. For maximum ratings use 45 mm air gap
No grounding wire required. DC inductive loads must be diode suppressed
3 Input control terminal screws M2.5 Slotted Drive
4 Output terminal screws (+ & -/M1 & M2) M2.5 Combo Drive
Minimum wire strip length 0.197 in [5 mm], maximum 0.235 in [6 mm] for input and output terminals
WARNING
RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE
• The product's side panels may be hot, allow the product to
cool before touching.
• Follow proper mounting instructions including torque values.
• Do not allow liquids or foreign objects to enter this product.
Failure to follow these instructions can result in serious injury,
or equipment damage.
DANGER
S1
Open
Closed
Open
Closed
S2
Open
Open
Closed
Closed
Input/Output
1
2
3
Reverse
Off
Off
On
Off
TIME DIAGRAM
4
5
fig. 3 Wiring Diagram for
DC Motor Reversing Contactor.
6
7
8
9
10
S1 switch
S2 switch
HAZARD OF ELECTRIC SHOCK,
EXPLOSION OR ARC FLASH
FWD Direction
• Turn off power supply before
working on this equipment.
REV Direction
Failure to follow these instructions
will result in death or serious injury.
Forward
Off
On
Off
Off
20 msec
20 msec
20 msec
interlock
Rev: 050911