Specifications

SSC Series
• IGBT based solid-state relay
• Ratings up to 25A @ 1,000 VDC
• DC control
PRODUCT SELECTION
25A
25A
SSC800-25
SSC1000-25
OUTPUT SPECIFICATIONS (1)
Description
Operating Voltage [VDC]
MaxImumTransient Overvoltage [Vpk]
Maximum Off-State Leakage Current @ Rated Voltage [mA]
Maximum Load Current (3) [Adc]
Minimum Load Current [mA]
Maximum Surge Current [Adc] (10ms)
Maximum On-State Voltage Drop @ Rated Current [Vdc]
Thermal Resistance Junction to Case (Rjc) [°C/W]
800 VDC
1000 VDC
0-800
900(4)
0.3
25
20
75
1.6
0.8
0-1000
1200(5)
0.3
25
20
75
1.6
0.8
INPUT SPECIFICATIONS (1)
Description
Nominal Control Voltage (6)
Control Voltage Range
Minimum Turn-On Voltage (7)
Minimum Turn-Off Voltage
Typical Input Current at Nominal Voltage
Nominal Input Impedance
Maximum Turn-On Time [msec]
Maximum Turn-Off Time [msec]
Suffix -12
Suffix -24
Suffix -36
12 VDC
8-16 VDC
8 VDC
1.0 VDC
15 mA
780 Ohm
1.5
1.5
24 VDC
20-28 VDC
20 VDC
1.0 VDC
15 mA
1500 Ohm
1.5
1.5
36 VDC
32-40 VDC
32 VDC
1.0 VDC
15 mA
2400 Ohm
1.5
1.5
GENERAL SPECIFICATIONS
Description
Dielectric Strength, Input/Output/Base (50/60Hz)(2)
Minimum Insulation Resistance (@ 500 V DC)(2)
Maximum Capacitance, Input/Output
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Weight (typical)
Encapsulation
Terminals
Recommended Terminal Screw Torque Range:
Parameters
2500 VRMS
109 Ohm
50 pF
-30 to 80°C
-40 to 125 °C
3.0 oz (86.5g)
Thermally conductive Epoxy
Screws and Saddle Clamps Furnished, Unmounted
6-32 Screws - 10 in lbs. 8-32 -20 in. lbs. (Screws dry without grase)
GENERAL NOTES
1) All parameters at 25°C unless otherwise specified.
2) Dielectric strength and insulation resistance are measured between input and output
3) Heat sinking required, for derating curves see next page.
4) Internal overvoltage protection included.
5) Internal overvoltage protection not included.
6) Use suffix -12, -24 or -36 to specify control voltage. For other values call factory Sample: SSC800-25-24
7) Operation below the specified minimum turn-on voltage may result in linear operation of the output and damage to the relay.
MECHANICAL SPECIFICATIONS
Transient Protection
All loads are inductive, even ones that are not so labeled. An
inductive load will produce harmful transient voltages when it
is turned off. The more perfect the switch, the larger the
transient voltages; the MOSFET output is so nearly an ideal
switch that the transient voltages produced by seemingly
“non-inductive” loads can cause damage if not suppressed.
Diodes should be fast recovery type with PIV rated greater
than supply voltage.
THERMAL DERATE INFORMATION
AGENCY APPROVALS
Designed in accordance with the requirements of IEC 62314
Rev. 120811
ANNEX - ENVIROMENTAL INFORMATION