SSC Series • IGBT based solid-state relay • Ratings up to 25A @ 1,000 VDC • DC control PRODUCT SELECTION 25A 25A SSC800-25 SSC1000-25 OUTPUT SPECIFICATIONS (1) Description Operating Voltage [VDC] MaxImumTransient Overvoltage [Vpk] Maximum Off-State Leakage Current @ Rated Voltage [mA] Maximum Load Current (3) [Adc] Minimum Load Current [mA] Maximum Surge Current [Adc] (10ms) Maximum On-State Voltage Drop @ Rated Current [Vdc] Thermal Resistance Junction to Case (Rjc) [°C/W] 800 VDC 1000 VDC 0-800 900(4) 0.3 25 20 75 1.6 0.8 0-1000 1200(5) 0.3 25 20 75 1.6 0.8 INPUT SPECIFICATIONS (1) Description Nominal Control Voltage (6) Control Voltage Range Minimum Turn-On Voltage (7) Minimum Turn-Off Voltage Typical Input Current at Nominal Voltage Nominal Input Impedance Maximum Turn-On Time [msec] Maximum Turn-Off Time [msec] Suffix -12 Suffix -24 Suffix -36 12 VDC 8-16 VDC 8 VDC 1.0 VDC 15 mA 780 Ohm 1.5 1.5 24 VDC 20-28 VDC 20 VDC 1.0 VDC 15 mA 1500 Ohm 1.5 1.5 36 VDC 32-40 VDC 32 VDC 1.0 VDC 15 mA 2400 Ohm 1.5 1.5 GENERAL SPECIFICATIONS Description Dielectric Strength, Input/Output/Base (50/60Hz)(2) Minimum Insulation Resistance (@ 500 V DC)(2) Maximum Capacitance, Input/Output Ambient Operating Temperature Range Ambient Storage Temperature Range Weight (typical) Encapsulation Terminals Recommended Terminal Screw Torque Range: Parameters 2500 VRMS 109 Ohm 50 pF -30 to 80°C -40 to 125 °C 3.0 oz (86.5g) Thermally conductive Epoxy Screws and Saddle Clamps Furnished, Unmounted 6-32 Screws - 10 in lbs. 8-32 -20 in. lbs. (Screws dry without grase) GENERAL NOTES 1) All parameters at 25°C unless otherwise specified. 2) Dielectric strength and insulation resistance are measured between input and output 3) Heat sinking required, for derating curves see next page. 4) Internal overvoltage protection included. 5) Internal overvoltage protection not included. 6) Use suffix -12, -24 or -36 to specify control voltage. For other values call factory Sample: SSC800-25-24 7) Operation below the specified minimum turn-on voltage may result in linear operation of the output and damage to the relay. MECHANICAL SPECIFICATIONS Transient Protection All loads are inductive, even ones that are not so labeled. An inductive load will produce harmful transient voltages when it is turned off. The more perfect the switch, the larger the transient voltages; the MOSFET output is so nearly an ideal switch that the transient voltages produced by seemingly “non-inductive” loads can cause damage if not suppressed. Diodes should be fast recovery type with PIV rated greater than supply voltage. THERMAL DERATE INFORMATION AGENCY APPROVALS Designed in accordance with the requirements of IEC 62314 Rev. 120811 ANNEX - ENVIROMENTAL INFORMATION