CRYDOM AO241

AO Series
• Mini-SIP SSR
• Ratings to 1A @ 280 VAC
• SCR or Triac output
• DC control
• Zero-crossing (resistive loads) or random-fire (inductive loads) output
PRODUCT SELECTION
Control Voltage
4-10 VDC
1A
AO241
AVAILABLE OPTIONS
OUTPUT SPECIFICATIONS (1)
Description
Operating Voltage (47-63Hz) [Vrms]
Transient Overvoltage [Vpk]
Maximum Off-State Leakage Current @ Rated Voltage [mArms]
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (3)
Maximum Load Current [Arms](3)
Minimum Load Current [Arms]
Maximum Surge Current (16.6ms) [Apk]
Maximum On-State Voltage Drop @ Rated Current [Vpk]
Minimum Power Factor (with Maximum Load)
AO241
24-280
600
0.1
500
1.0
0.025
40
1.5
0.5
INPUT SPECIFICATIONS (1)
Description
Control Voltage Range
Must Turn On Voltage
Must Turn Off Voltage
Typical Input Current @ 5 VDC
Nominal Input Impedance
Maximum Turn-On Time [msec]
Maximum Turn-Off Time [msec]
Parameters
4-10 VDC
4.0 VDC
1.0 VDC
15 mAdc
300 Ohm
1/2 Cycle
1/2 Cycle
GENERAL SPECIFICATIONS
Description
Parameters
Dielectric Strength, Input/Output/Base (50/60Hz)(2)
Minimum Insulation Resistance (@ 500 VDC)(2)
2500 Vrms
10 9 Ohm
Maximum Capacitance, Input/Output
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Weight (typical)
Encapsulation
8.0 pF
-30 to 80˚C
-30 to 125˚C
0.15 oz. (4.3g)
Thermally Conductive Epoxy
GENERAL NOTES
1) All parameters at 25°C unless otherwise specified.
2) Dielectric and ins ulation resistence are measured between input and output
3) Off-State dv/dt test method per EIA/NARM standard RS-443
MECHANICAL SPECIFICATIONS
DC CONTROL.
PIN 1: AC LOAD
PIN 2: AC LOAD
PIN 3: +DC CONTROL
PIN 4: -DC CONTROL
THERMAL DERATE INFORMATION
AGENCY APPROVALS
UL E116950
CSA LR81689
Rev. 010511
ANNEX - ENVIROMENTAL INFORMATION