76.2(W) x 32(H) x 127(L) mm DPS-80AP-1 A FEATURES Input Voltage range 90~264Vac auto range Frequency 47~63Hz Efficiency The average efficiency at 25%, 50%, 75% and 100% load ≥ 87% Input Current Output Protection Environment 100Vac/55.5V/1.97A load ≤ 2.5A 240Vac/55.5V/1.97A load ≤ 1.25A 55.5V 0A to 1.97A Over-current Auto recovery Over-temperature Latch Short Auto recovery Over-voltage Latch Operating temp. Fan less: 100W@0 to 50°C, 80W@0 to 60°C ; With fan(<3CFM): 110W@0 to 60°C Storage temp. -40 to 85°C Operating humidity 10% - 90% Storage humidity 5% - 95% • Total power 110W • 90-264Vac auto range input • High reliability: >100,000 hours @ full load • and normal input (25 ℃) • Protection: Short / Over-current / Over-voltage • / Over-temperature • CCC: 5000 meter • Bulk Cap: JP Type • Safety: UL/cUL, TUV, CB , CCC, CE,BSMI • EMI: CLASS B • Surge: 4KV common mode 2KV differential mode DPS-80AP-1 A Electrical Safety UL/cUL, TUV, CB,CCC,CE, BSMI refer to EN 60950-1 CE In conformance with EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/EC EMI: refer to CISPR 22 ,FCC ,VCCI:CLASS B Air Discharge: ± 8KVmin ESD(IEC61000-4-2) Safety Standards/Directives EMC EFT(IEC61000- 4-4) Contact Discharge: ±4KVmin +/- 1KV Common Mode:+/- 4KV Surge(IEC61000-4-5) Isolation Input to Output 3.0KVac or 4242Vdc Input to Ground 1.5KVac or 2121Vdc Output to Ground 1.5KVac or 2121Vdc Different Mode:+/- 2KV ▓Power de-rating curve