DPS-80AP

76.2(W) x 32(H) x 127(L) mm
DPS-80AP-1 A
FEATURES
Input
Voltage range
90~264Vac auto range
Frequency
47~63Hz
Efficiency
The average efficiency at 25%, 50%, 75% and
100% load ≥ 87%
Input Current
Output
Protection
Environment
100Vac/55.5V/1.97A load ≤ 2.5A
240Vac/55.5V/1.97A load ≤ 1.25A
55.5V
0A to 1.97A
Over-current
Auto recovery
Over-temperature
Latch
Short
Auto recovery
Over-voltage
Latch
Operating temp.
Fan less: 100W@0 to 50°C, 80W@0 to 60°C ;
With fan(<3CFM): 110W@0 to 60°C
Storage temp.
-40 to 85°C
Operating humidity
10% - 90%
Storage humidity
5% - 95%
• Total power 110W
• 90-264Vac auto range input
• High reliability: >100,000 hours @ full load
•
and normal input (25 ℃)
• Protection: Short / Over-current / Over-voltage
•
/ Over-temperature
• CCC: 5000 meter
• Bulk Cap: JP Type
• Safety: UL/cUL, TUV, CB , CCC, CE,BSMI
• EMI: CLASS B
• Surge: 4KV common mode
2KV differential mode
DPS-80AP-1 A
Electrical Safety
UL/cUL, TUV, CB,CCC,CE, BSMI
refer to EN 60950-1
CE
In conformance with EMC Directive 2004/108/EC and Low Voltage
Directive 2006/95/EC
EMI: refer to CISPR 22 ,FCC ,VCCI:CLASS B
Air Discharge: ± 8KVmin
ESD(IEC61000-4-2)
Safety Standards/Directives
EMC
EFT(IEC61000- 4-4)
Contact Discharge: ±4KVmin
+/- 1KV
Common Mode:+/- 4KV
Surge(IEC61000-4-5)
Isolation
Input to Output
3.0KVac or 4242Vdc
Input to Ground
1.5KVac or 2121Vdc
Output to Ground
1.5KVac or 2121Vdc
Different Mode:+/- 2KV
▓Power de-rating curve