50.8(W) x 30.5(H) x 101.6(L) mm DPS-60AP-5 A FEATURES Input Voltage range 90~264Vac auto range Frequency 47~63Hz Efficiency The average efficiency at 25%, 50%, 75% and 100% load 87% Input Current Output 100Vac /12V/5A load 2.0A 240Vac / 12V/5A load 1.2A • Total power 60W(only for regulatory) 70W(continuous power) • 90-264Vac auto range input • High reliability: >100,000 hours @ full load • • 12V 0A to 5A (5.83A) Over-current Auto recovery • Over-temperature Latch • Short Auto recovery Over-voltage Auto recovery Operating temp. 0 to 50C Full load,60C 80% load Storage temp. -20 to 70 C Operating humidity 10% - 90% Storage humidity 10% - 95% • • Protection Environment and normal input (25 ℃) Protection: Short / Over-current / Over-voltage / Over-temperature CCC: 5000 meter Bulk Cap: JP Type Safety: UL/cUL, TUV, CB by Demko ,CCC EMI: CLASS B Surge: 4KV common mode 2KV differential mode DPS-60AP-5 A Electrical Safety UL/cUL, TUV, CB,CCC,CE, BSMI refer to EN 60950-1 CE In conformance with EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/EC EMI: refer to CISPR 22 ,FCC ,VCCI:CLASS B Air Discharge: 15KV min Safety Standards/Directives ESD(IEC61000-4-2) Contact Discharge: 8KV min. EMC EFT(IEC61000- 4-4) +/- 2KV Common Mode:+/- 4KV Surge(IEC61000-4-5) Isolation Input to Output 3.0KVac Different Mode:+/- 2KV ▓Power de-rating curve