Surge Protection Made Simple™ for IEC Applications IEC Class II Surge Arresters for 230 Volt, 2-Pole TN & TT Systems Description The Cooper Bussmann® IEC Class II 230 volt, two-pole, modular surge arresters feature local, easy ID™ visual indication and optional remote contact signaling. The unique module locking system fixes the protection module to the base part. Modules can be easily replaced without tools by simply depressing the release buttons. Integrated mechanical coding between the base and protection module ensures against installing an incorrect replacement module. BSPM2275TN(R) BSPH2275TT(R) 230 Volt models are offered with MCOV ratings of 255 and 275 volts. TN System Arresters The features of these single-pole devices are for use in single-phase 230 volt TN systems (“2-0” circuit). TT System Arrester The features of these single-pole devices are for use in single-phase 230 volt TT and TNS systems (“1-1” circuit). Remote Signaling Contact Visual Status Indication The three-pole terminal remote signaling contact versions have a floating changeover contact for use as a break or make contact, according to circuit concept. Remote Signal Contact Available MOV Thermal Disconnector Gas Discharge Tube (single) Circuit Diagrams Dimensions - mm BSPM2275TN(R) BSPH2275TT(R) Shown with optional remote contact signaling Shown with optional remote contact signaling Shown with optional remote contact signaling www.cooperbussmann.com/Surge 0211 BU-SB101433 Page 1 of 2 Data Sheet 1167_A4 Ordering Information System Voltage/Poles Max. continuous operating AC voltage (MCOV) [UC] Max. Continuous operating AC voltage (MCOV) [L-N] [UC] Max. Continuous operating AC voltage (MCOV) [N-PE] [UC] Catalog Numbers: Without Remote Signaling With Remote Signaling Replacement Modules: MOV Technology Spark Gap technology 230V/2 275V --BSPM2275TN BSPM2275TNR BPM275IEC -- 230V/2 -275V 255V BSPH2275TT BSPH2275TTR BPM275IEC BPSNPEIEC* -_< 1.25kV _< 1kV ----_< 25 ns --335V/5 sec. --- 12kA --_< 1.25kV _< 1kV _< 1.5kV 100A rms -_< 25 ns _< 100 ns -335V/5 sec. 1200V/200 ms Specifications Lightning impulse current (10/350 µs) [N-PE] [Iimp] Voltage protection level [UP] Voltage protection level at 5kA [UP] Voltage protection level [L-N] [UP] Voltage protection level [L-N] at 5kA [UP] Voltage protection level [N-PE] [UP] Follow current extinguishing capability [N-PE] [Ifi] Response time [tA] Response time [L-N] [tA] Response time [N-PE] [tA] Temporary overvoltage (TOV) [UT] Temporary overvoltage (TOV) [L-N] [UT] Temporary overvoltage (TOV) [N-PE] [UT] SPD according to EN 61643-11 SPD according to IEC 61643-1 Nominal discharge current (8/20 µs) [In] Max. discharge current (8/20 µs) [Imax] Max. mains-side overcurrent protection Short-circuit withstand capability for max. mains-side overcurrent protection Nominal AC voltage [UN] TOV characteristics Operating temperature range [TU] Operating state/fault indication Number of ports Cross-sectional area (min.) Cross-sectional area (max.) Mounting Enclosure material Location category Degree of protection Capacity Standards Information Product Warranty Type 2 Class II 20kA 40kA 125A gL/gG 50kA rms 230V withstand -40°C to +80°C green (good)/red (replace) 1 1.5mm2/14AWG solid/flexible 35mm2/2AWG stranded-25mm2/4AWG flexible 35mm DIN rail per EN 60715 Thermoplastic, UL 94V0 Indoor IP20 2 mods., DIN 43880 KEMA Five Years** Remote Contact Signaling Remote Contact Signaling Type AC Switching Capacity (Volts/Amps) DC Switching Capacity (Volts/Amps) Changeover Contact 250V/0.1A 250V/0.1A; 125V/0.2A; 75V/0.5A Conductor Ratings and Cross-Sectional Area for Remote Contact Signal Terminals 60/75°C Max. 1.5mm2/14AWG Solid/Flexible Ordering Information Order from Catalog Numbers Above * N-PE Surge arrester for location between neutral conductor and protective conductor in TT systems. ** See Cooper Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge. Recommended Cooper Bussmann Back Up Fuses DIN Fuse Size NH Fuse Part Number 00 125NHG00B 0 125NHG0B 01 125NHG01B 02 125NHG02B The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Cooper Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. © 2011 Cooper Bussmann w w w. c o o p e r b u s s m a n n . c o m 0211 BU-SB101433 Page 2 of 2 Data Sheet 1167_A4