SPD Catalogue SPD Catalogue for AC applications Eaton and Cooper united. Energizing a world that demands more. We deliver: s s Electrical solutions that use less energy, improve power reliability and make the places we live and work safer and more comfortable Hydraulic and electrical solutions that enable machines to deliver more productivity without wasting power s Aerospace solutions that make aircraft lighter, safer and less costly to operate, and help airports operate more efficiently s Vehicle drivetrain and powertrain solutions that deliver more power to cars, trucks and buses, while reducing fuel consumption and emissions Discover today’s Eaton. Powering business worldwide !SAGLOBALDIVERSIFIEDPOWERMANAGEMENTCOMPANYWE HELPCUSTOMERSWORLDWIDEMANAGETHEPOWERNEEDEDFOR BUILDINGSAIRCRAFTTRUCKSCARSMACHINERYANDBUSINESSES %ATONSINNOVATIVETECHNOLOGIESHELPCUSTOMERSMANAGE ELECTRICALHYDRAULICANDMECHANICALPOWERMORERELIABLY EFFICIENTLYSAFELYANDSUSTAINABLY 2 EATON SPD Catalogue 7EPROVIDEINTEGRATEDSOLUTIONSTHATHELPMAKEENERGY INALLITSFORMSMOREPRACTICALANDACCESSIBLE 7ITHSALESOFBILLION%ATONHASAPPROXIMATELY EMPLOYEESAROUNDTHEWORLDANDSELLSPRODUCTS INMORETHANCOUNTRIES Eaton.com The need for Surge Protection Overvoltage surges can cause irreparable damage to electrical equipment that our infrastructure, industry and homes are becoming increasingly reliant upon. These transient events can lead to corrupted software, industrial downtime and PCB damage which can be catastrophic due to the loss of information, loss of output and high replacement cost. Surges can be caused by a variety of different sources; such as lightning strikes, industrial machinery and power switching. It is essential to protect electrical equipment against these events to ensure power quality and maximise the lifetime of the electrical devices. After extensive research and development has been conducted, Bussmann is able to offer a comprehensive protective solution for your equipment, eliminating the disruptive and damaging effects that surge and overvoltage conditions can cause. Causes of transients and surges t Lightning strikes: t t Large scale impact with high current and voltage but the least common occurrence. Power switching: t Utility and customer load switching such as motors, large loads, capacitor banks, fuse and circuit breaker operation. Damaging effects of transients and surges 1. Disruptive—a voltage transient enters an electronic component and it is interpreted as a valid logic command resulting in system lock-up, malfunction, faults or corrupted files. 2. Dissipative—associated with short duration, low level energy surges, resulting in equipment failure over time including electronic components, ballasts, motors and controllers, service entrance equipment, panelboards and switchgear. 3. Destructive—associated with high level energy surges, resulting in immediate equipment failure including electronic components, motors and controllers, service entrance equipment, panelboards and switchgear. EATON SPD Catalogue 3 Earthing system protection International standard, IEC 60364 defines the three families of Earthing System protection that uses two letter codes to signify the protection that it provides, TN, TT and IT. The configuration of surge protection will depend on the Earthing System used. TN Within TN systems there is a direct connection point with Earth and a direct connection to neutral at the origin of the installation, usually the start point of the three-phase system. TN-S Separate Protective Earth (PE) and Neutral (N) conductors from transformer to consuming device, which are not connected together at any point after the building distribution point. Figure 1: TN-S wiring diagram. Typical Applications: t Residential t Industrial TN-C Combined PE and N conductor from the transformer to the consuming element. This system is not permitted for conductors of less than 10mm² or for portable equipment. The PEN conductor must be connected to a number of Earth electrodes in the installation. Figure 2: TN-C wiring diagram. TT In a TT earthing system the customer must provide their own connection to Earth, independent of any Earth connection at the generator. Typical Applications: t Telecommunications Figure 3: TT wiring diagram. IT In an IT network the electrical distribution system has no connection to Earth or it only has a high impedance connection. In an IT system, an insulation monitoring device is used to monitor the impedance. Figure 4: IT wiring diagram. 4 EATON SPD Catalogue Degrees of protection SPDs are divided into three different levels of protection , Type 1, Type 2 and Type 3, depending on their function application, as determined by IEC 61643-1. SPD Type 1 A Type 1 SPD protects electrical installations to the lightning grid or rod. It can discharge the surge current from the effect of lightning spreading from the Earth conductor to the network conductors. Figure 5 characterises the current wave from a direct lightning strike. SPD Type 2 Figure 5: 10/350μs current wave. A Type 2 SPD is the secondary protection system for all low voltage electric installations. This is installed into each electrical switchboard and prevents the spread of overvoltage’s in the electrical systems, protecting the loads. Figure 6 characterises the current wave from the effects of an indirect lightning strike. SPD Type 3 A Type 3 SPD has a low discharge current capacity. They must therefore be installed as a supplement to a Type 2 SPD in the vicinity of sensitive loads. Figure 6: 8/20μs current wave Type 3 SPDs are characterised by the wave form shown in Figure 7. Figure 7: 1.2/ 50μs voltage wave EATON SPD Catalogue 5 Plug-in modules Description When an SPD reaches the end of its life and indicates that it needs to replaced, Bussmann is able to provide replacement modules for the entire voltage range on offer. These thermoplastic modules are IEC certified to IEC61643 and save both time and money by simply clipping into the place of the operated module. This swift exchange of parts ensures that the system is protected which prevents industrial downtime or periods when the electrical equipment is left vulnerable to voltage surges. SPCT2-335 Ordering information Part numbers SPCT2-075 SPCT2-135 SPCT2-175 SPCT2-280 SPCT2-335 SPCT2-385 SPCT2-460 SPCT2-580 System voltage 75 V 135 V 175 V 280 V 335 V 385 V 460 V 580 V 260V Article numbers 167577 167582 167587 167592 167597 167602 167607 167612 167617 SPCT2-NPE60 Specifications Max.continuous operating AC voltage [UC] 75 VAC 135 VAC 175 VAC 280 VAC 335 VAC 385 VAC 460 VAC 580 VAC 260 VAC Voltage protection level [UP] < 550 V < 800 V < 1.0 kV < 1.4 kV < 1.6 kV < 1.8 kV < 2.2 kV < 2.6 kV 1.0 Kv - Voltage protection level at 5kA [UP] 400 V 550 V 700 V 1000 V 1200 V 1350 V 1700 V 2000 V Max. mains-side overcurrent protection 125 A gL/gG - 125 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG - Short circuit withstand capability for max. mains-side overcurrent protection 50 kA rms 50 kA rms 50 kA rms 50 kA rms 50 kA rms 50 kA rms 50 kA rms 50 kA rms - Temporary overvoltage (TOV) UT 75 VAC 135 VAC 175 VAC 350 VAC 415 VAC 415 VAC 580 VAC 580 VAC - < 25 ns < 25 ns < 25 ns < 25 ns < 25 ns < 25 ns < 25 ns < 25 ns < 100 ns Temporary overvoltage NPE 1200 VAC (200 ms) Response time [tA] 6 Follow current extinguishing capability [Ifi] - - - - - - - - 100 A rms Nominal discharge current (8/20μs) In 15 kA 20 kA 20 kA 20 kA 20 kA 20 kA 20 kA 20 kA 20 kA Max discharge current [Imax] 30 kA 40 kA 40 kA 40 kA 40 kA 40 kA 40 kA 40 kA 40 kA IEC 61643 Standards information IEC 61643 IEC 61643 IEC 61643 IEC 61643 IEC 61643 IEC 61643 IEC 61643 IEC 61643 SPD according to EN 61643-11 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 SPD according to IEC 61643-1 Class II Class II Class II Class II Class II Class II Class II Class II Class II Operating temperature range -40oC to + 70oC -40oC to + 70oC -40oC to + 70oC -40oC to + 70oC -40oC to + 70oC -40oC to + 70oC -40oC to + 70oC -40oC to + 70oC -40°C to + 70°C Operating state/Fault indication green (good)/ red (replace) green (good)/ red (replace) green (good)/ red (replace) green (good)/ red (replace) green (good)/ red (replace) green (good)/ red (replace) green (good)/ red (replace) green (good)/ red (replace) Blue, good. Cross sectional area (min.) 4 mm2 4 mm2 4 mm2 4 mm2 4 mm2 4 mm2 4 mm2 4 mm2 4mm² Cross sectional area (max.) 25 mm2 25 mm2 25 mm2 25 mm2 25 mm2 25 mm2 25 mm2 25 mm2 25mm² Mounting Quick fastening on DIN rail according to IEC/ EN 60715 Quick fastening on DIN rail according to IEC/ EN 60715 Quick fastening on DIN rail according to IEC/ EN 60715 Quick fastening on DIN rail according to IEC/ EN 60715 Quick fastening on DIN rail according to IEC/ EN 60715 Quick fastening on DIN rail according to IEC/ EN 60715 Quick fastening on DIN rail according to IEC/ EN 60715 Quick fastening on DIN rail according to IEC/ EN 60715 Quick fastening on DIN rail according to IEC/ EN 60715 Enclosure material Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Location category Indoor Indoor Indoor Indoor Indoor Indoor Indoor Indoor Indoor Rated frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50/ 60 Hz Degree of protection IP40 IP40 IP40 IP40 IP40 IP40 IP40 IP40 IP40 EATON SPD Catalogue Single pole T1 and T1/T2 Description Bussmann is able to provide SPDs to meet a variety of applications and requirements. This range is specifically designed and manufactured for customised protective system solutions. The modular designs feature integrated fault indication which turns from green to red, visually alerting the operator to whether or not the device has reached the end of its life and needs to be replaced with a new module. Manufactured from thermoplastic, the SPDs are IEC certified for use in environments with an operational temperature range from –40°C to +70°C. Configurations of SPDs can be customised for the application or for the installation location, the module locking system with module release buttons make the replacement easy and without tools by depressing the buttons and lifting the module out. Ordering information General arrangement SPBT12-280 T1 T1 / T2 Part numbers SPI-35-400 SPI-50-NPE SPI-100-NPE SPBT12-280-1 SPBT12-280-1-NPE SPBT12-NPE100 System voltage/poles 440 V / 1 260 V / 1+NPE 260 V / 1+NPE 280 V / 1 280 V /1 + NPE 255 V Article numbers 267487 263138 263139 158306 158308 158307 Replacement modules - - - SPBT12-280 SPBT12-280 SPBT12-NPE100 Specifications Max. continuous operating AC voltage [Uc] 440 VAC 260 VAC 260 VAC 280 VAC 280 VAC / 255 VAC 255 VAC Voltage protection level [UP] 1.5 kV 1.5 kV 1.5 kV < 1.5 kV < 1.5 kV < 1.5 kV Voltage protection level at 5 kA [UP] - - - 950 V 950 V - Max. mains-side overcurrent protection 125 A gL - - 160 A gL/gG 160 A gL/gG - Short circuit withstand capability for max. mains-side overcurrent protection - - - 50 kA rms 50 kA rms - - Temporary overvoltage test value UT (5 s) 25 kA rms - - 370 VAC 348 / 370 VAC Temporary overvoltage NPE 440 VAC 1200 VAC 1200 VAC - 1200 VAC 1200 VAC (200 ms) Response time (rate of voltage rise 5 kV/μs) < 100 ns < 100 ns < 100 ns < 25 ns < 25 ns/ < 100 ns < 100 ns Follow current interrupt rating [Ifi] 3 kA rms 500 A rms 100 A rms - 100 A rms 100A rms Lightning impulse current (10/350μs) [limp] 35 kA 50 kA 100 kA 12.5 kA 12.5 kA / 100 kA 100 kA Nominal discharge current (8/20μs) In 35 kA 50 kA 100 kA 25 kA 25 kA / 100 kA 100 kA Max discharge current [Imax] 35 kA 50 kA 100 kA 50 kA 50 kA / 100 kA 100 kA Standards information IEC 61643 IEC 61643 IEC 61643 IEC 61643 IEC 61643 IEC 61643 SPD according to EN 61643-11 Type 1 Type 1 Type 1 Type 1 & 2 Type 1 & 2 Type 1 & 2 SPD according to IEC 61643-1 Class I Class I Class I Class I & II Class I & II Class I & II Operating temperature range -40oC to +85oC -40oC to +85oC 40oC to +85oC -40oC to +70oC -40oC to +70oC -40oC to + 70oC Operating state/Fault indication - - - green (good) / red (replace) green (good) / red (replace) green (good)/ red (replace) Cross sectional area (min.) 45 mm2 45 mm2 45 mm2 4 mm2 4 mm2 4 mm2 Cross sectional area (max.) 90 mm 2 2 2 Mounting 25 mm 25 mm2 Quick fastening on DIN rail according to IEC/EN 60715 Quick fastening on DIN rail according to IEC/ EN 60715 Quick fastening on DIN rail according to IEC/EN 60715 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 25 mm 2 2 90 mm 90 mm Quick fastening on DIN rail according to IEC/EN 60715 Quick fastening on DIN rail according to IEC/EN 60715 Quick fastening on DIN rail according to IEC/EN 60715 Enclosure material Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Location category Indoor Indoor Indoor Indoor Indoor Indoor Rated frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50/60Hz Degree of protection IP40 IP40 IP40 IP40 IP40 IP40 Product warranty 2 Years 2 Years 2 Years 2 Years 2 Years 2 years Auxiliary switch ASAUXSC-SPM ASAUXSC-SPM ASAUXSC-SPM ASAUXSX-SPM ASAUXSX-SPM ASAUXSC-SPM EATON SPD Catalogue 7 Single pole T2 Description Bussmann is able to offer a variety of T2 single pole and single pole plus neutral SPDs. These devices are suitable for use within a range of applications, allowing the customisation of the configuration of SPDs within a specific system. The neutral and protective earth unit incorporates a spark gap device, shown by the blue indicator screen built into the unit, adding extra levels of protection into the configuration of SPDs. Additionally, there are local and remote monitoring options available. The ASAUXC-SPM device clips onto the end of any configuration of SPDs, providing real time information to the operator’s computer system on the status of the SPDs. Ordering information T2 Part numbers SPCT2-075-1 SPCT2-135-1 SPCT2-175-1 SPCT2-280-1 SPCT2-335-1 SPCT2-385-1 SPCT2-460-1 System voltage/poles 75 V / 1 135 V / 1 175 V / 1 280 V / 1 335 V / 1 385 V / 1 460 V / 1 Article numbers 167578 167583 167588 167593 167598 167603 167608 Replacement modules SPCT2-075 SPCT2-135 SPCT2-175 SPCT2-280 SPCT2-335 SPCT2-385 SPCT2-460 Specifications 8 Max. continuous operating AC voltage [Uc] 75 VAC 135 VAC 175 VAC 280 VAC 335 VAC 385 VAC 460 VAC Voltage protection level [UP] < 550 V < 800 V < 1.0 kV < 1.4 kV < 1.6 kV <1.8 kV < 2.2 kV Voltage protection level at 5 kA [UP] 400 V 550 V 700 V 1000 V 1200 V 1350 V 1700 V Max. mains-side overcurrent protection 125 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG Short circuit withstand capability for max. mains-side overcurrent protection 50 kA rms 50 kA rms 50 kA rms 50 kA rms 50 kA rms 50 kA rms 50 kA rms Temporary overvoltage test value UT (5 s) 75 VAC 135 VAC 175 VAC 350 VAC 415 VAC 415 VAC 580 VAC Temporary overvoltage NPE - - - - - - - Response time (rate of voltage rise 5 kV/μs) < 25 ns < 25 ns < 25 ns < 25 ns < 25 ns < 25 ns < 25 ns Follow current interrupt rating [Ifi] - - - - - - - Lightning impulse current (10/350μs) [limp] - - - - - - - Nominal discharge current (8/20μs) In 15 kA 20 kA 20 kA 20 kA 20 kA 20 kA 20 kA Max discharge current [Imax] 30 kA 40 kA 40 kA 40 kA 40 kA 40 kA 40 kA Standards information IEC 61643 IEC 61643 IEC 61643 IEC 61643 IEC 61643 IEC 61643 IEC 61643 SPD according to EN 61643-11 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 SPD according to IEC 61643-1 Class II Class II Class II Class II Class II Class II Class II Operating temperature range -40oC to +70oC -40oC to +70oC -40oC to + 70oC -40oC to +70oC -40oC to +70oC -40oC to +70oC -40oC to +70oC Operating state/Fault indication green (good) / red (replace) green (good) / red (replace) green (good) / red (replace) green (good) / red (replace) green (good) / red (replace) green (good) / red (replace) green (good) / red (replace) Cross sectional area (min.) 4 mm2 4 mm2 4 mm2 4 mm2 4 mm2 4 mm2 4 mm2 Cross sectional area (max.) 25 mm2 25 mm2 25 mm2 25 mm2 25 mm2 25 mm2 25 mm2 Mounting Quick fastening on DIN rail according to IEC/ EN 60715 Quick fastening on DIN rail according to IEC/ EN 60715 Quick fastening on DIN rail according to IEC/ EN 60715 Quick fastening on DIN rail according to IEC/ EN 60715 Quick fastening on DIN rail according to IEC/ EN 60715 Quick fastening on DIN rail according to IEC/ EN 60715 Quick fastening on DIN rail according to IEC/ EN 60715 Enclosure material Thermoplastic UL 94 V2 Thermoplastic UL 94V2 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Location category Indoor Indoor Indoor Indoor Indoor Indoor Indoor Rated frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz Degree of protection IP40 IP40 IP40 IP40 IP40 IP40 IP40 Product warranty 2 Years 2 Years 2 years 2 years 2 years 2 years 2 years Auxiliary switch ASAUXSC-SPM ASAUXSC-SPM ASAUXSC-SPM ASAUXSC-SPM ASAUXSC-SPM ASAUXSC-SPM ASAUXSC-SPM EATON SPD Catalogue SPCT2-280-1 General arrangement SPCT2-580-1 SPCT2-NPE60-1 SPCT2-280-1-NPE SPCT2-335-1-NPE SPCT2-385-1-NPE SPCT2-460-1-NPE SPCT2-580-1-NPE 580 V / 1 260V/ 1 280 V / 1 + NPE 335 V / 1 + NPE 385 V / 1 + NPE 460 V / 1 + NPE 580 V / 1 + NPE 167613 167618 167619 167621 167623 167625 167627 SPCT2-580 SPCT2-NPE60 SPCT2-280 SPCT2-335 SPCT2-385 SPCT2-460 SPCT2-580 580 VAC 260 VAC 280 VAC 335 VAC 385 VAC 460 VAC 580 VAC < 2.6 kV 1.0 Kv < 1.4 kV < 1.6 kV < 1.8 kV < 2.2 kV < 2.6 kV 2000 V - 1000 V 1200 V 1350 V 1700 V 2000 V 125 A gL/gG - 125 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG 50 kA rms - 50 kA rms 50 kA rms 50 kA rms 50 kA rms 50 kA rms 580 VAC - 350 VAC 415 VAC 415 VAC 580 VAC 580 VAC - 1200 VAC (200 ms) 1200 VAC 1200 VAC 1200 VAC 1200 VAC 1200 VAC < 25 ns <100 ns < 25 ns / < 100 ns < 25 ns / < 100 ns < 25 ns / < 100 ns < 25 ns / < 100 ns < 25 ns / < 100 ns - 100 A rms 100 A rms 100 A rms 100 A rms 100 A rms 100 A rms - - - - - - - 20 kA 20 kA 20 kA / 100 kA 20 kA / 100 kA 20 kA / 100 kA 20 kA / 100 kA 20 kA / 100 kA 40 kA 40 kA 40 kA / 100 kA 40 kA / 100 kA 40 kA / 100 kA 40 kA / 100 kA 40 kA / 100 kA IEC 61643 IEC 61643 IEC 61643 IEC 61643 IEC 61643 IEC 61643 IEC 61643 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 Class II Class II Class II Class II Class II Class II Class II -40oC to +70oC -40°C to + 70°C -40oC to +70oC -40oC to +70oC -40oC to +70oC -40oC to +70oC -40oC to +70oC green (good) / red (replace) Blue, good green (good) / red (replace) green (good) / red (replace) green (good) / red (replace) green (good) / red (replace) green (good) / red (replace) . 4 mm2 4 mm2 4 mm2 4 mm2 4 mm2 4 mm2 4 mm2 25 mm2 25 mm2 25 mm2 25 mm2 25 mm2 25 mm2 25 mm2 Quick fastening on DIN rail according to IEC/ EN 60715 Quick fastening on DIN rail according to IEC/ EN 60715 Quick fastening on DIN rail according to IEC/ EN 60715 Quick fastening on DIN rail according to IEC/ EN 60715 Quick fastening on DIN rail according to IEC/ EN 60715 Quick fastening on DIN rail according to IEC/ EN 60715 Quick fastening on DIN rail according to IEC/ EN 60715 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Indoor Indoor Indoor Indoor Indoor Indoor Indoor 50 / 60 Hz 50/ 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz IP40 IP40 IP40 IP40 IP40 IP40 IP40 2 years 2 Years 2 years 2 years 2 years 2 years 2 years ASAUXSC-SPM ASAUXSC-SPM ASAUXSC-SPM ASAUXSC-SPM ASAUXSC-SPM ASAUXSC-SPM ASAUXSC-SPM EATON SPD Catalogue 9 TN-S protection systems Description Bussmann is able to provide a range of SPDs that are certified for use within TN-S protection systems. The TN-S system is appropriate within the many residential and industrial electric systems, especially in Europe. This is because the PE and N are separate conductors which are connected together only near a power source. The modular designs feature integrated fault indication which turns from green to red, visually alerting the operator to whether or not the device has reached the end of its life and needs to be replaced with a new module. Manufactured from thermoplastic, the SPDs are IEC certified for use in environments with an operational temperature range from –40°C to +70°C Configurations of SPDs can be customised for the application or for the installation location, the module locking system with module release buttons make the replacement easy and without tools by depressing the buttons and lifting the module out. Ordering information T1/T2 Part numbers SPBT12-280-4 SPBT12-280-3-NPE SPCT2-280-3-NPE SPCT2-335-3-NPE SPCT2-385-3-NPE SPCT2-460-3-NPE System voltage/poles 280 V / 4 280 V / 3 + NPE 280 V / 3 + NPE 335 V / 3 + NPE 385 V / 3 + NPE 460 V / 3 + NPE Article numbers 158331 158332 167620 167622 167624 167626 Replacement modules SPBT12-280 SPBT12-280 SPCT2-280 SPCT2-335 SPCT2-385 SPCT2-460 TN-S TN-S TN-S TN-S TN-S TN-S Specifications Line system type Max.continuous operating AC voltage [UC] 280 VAC 280 VAC / 255 VAC 280 VAC 335 VAC 385 VAC 460 VAC Voltage protection level [UP] < 1.5 kV < 1.5 kV < 1.4 kV < 1.6 kV < 1.8 kV < 2.2 kV Voltage protection level at 5 kA [UP] 950 V 950 V 1000 V 1200 V 1350 V 1700 V Max. mains-side overcurrent protection 160A gL/gG 160 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG Short circuit withstand capability for max. mains-side overcurrent protection 50 kA rms 50 kA rms 50 kA rms 50 kA rms 50 kA rms 50 kA rms Temporary overvoltage test value UT (5 s) 370 VAC 348 /370 VAC 350 VAC 415 VAC 415 VAC 580 VAC Temporary overvoltage NPE - 1200 VAC 1200 VAC 1200 VAC 1200 VAC 1200 VAC Response time (rate of voltage rise 5 kV/μs) < 25 ns < 25 ns / < 100 ns < 25 ns / < 100 ns < 25 ns / < 100 ns < 25 ns / < 100 ns < 25 ns / < 100 ns Follow current extinguishing capability [Ifi] - 100 A rms 100 A rms 100 A rms 100 A rms 100 A rms Lightning impulse current (10/350μs) [limp] 12.5 kA 3 x 12.5 kA / 100 kA - - - - Nominal discharge current (8/20μs) In 25 kA 3 x 25 kA / 100 kA 3 x 20 kA / 100 kA 3 x 20 kA / 100 kA 3 x 20 kA / 100 kA 3 x 20 kA / 100 kA Max discharge current [Imax] 50 kA 3 x 50 kA / 100 kA 3 x 40 kA / 100 kA 3 x 40 kA / 100 kA 3 x 40 kA / 100 kA 3 x 40 kA / 100 kA Standards information IEC 61643 IEC 61643 IEC 61643 IEC 61643 IEC 61643 IEC 61643 SPD according to EN 61643-11 Type 1 & 2 Type 1 & 2 Type 2 Type 2 Type 2 Type 2 SPD according to IEC 61643-1 Class I & II Class I & II Class II Class II Class II Class II Operating temperature range -40oC to +70oC -40oC to +70oC -40oC to +70oC -40oC to +70oC -40oC to +70oC -40oC to +70oC Operating state/Fault indication green (good) / red green (good) / red green (good) / red green (good) / red green (good) / red green (good) / red (replace) (replace) (replace) (replace) (replace) (replace) 4 mm2 4 mm2 4 mm2 4 mm2 4 mm2 Cross sectional area (min.) 10 Cross sectional area (max.) 25 mm Mounting 2 2 2 25 mm2 Quick fastening on DIN rail according to IEC/ EN 60715 Quick fastening on DIN rail according to IEC/ EN 60715 Quick fastening on DIN rail according to IEC/EN 60715 Thermoplastic UL 94 V2 Thermoplastic UL94 V2 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Indoor Indoor Indoor Indoor 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz IP40 IP40 IP40 IP40 IP40 2 Years 2 Years 2 Years 2 Years 2 Years ASAUXSX-SPM ASAUXSC-SPM ASAUXSC-SPM ASAUXSX-SPM ASAUXSX-SPM 25 mm Quick fastening on DIN rail according to IEC/ EN 60715 Quick fastening on DIN rail according to IEC/ EN 60715 Quick fastening on DIN rail according to IEC/ EN 60715 Enclosure material Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Location category Indoor Indoor Rated frequency 50 / 60 Hz Degree of protection IP40 Product warranty 2 Years Auxiliary switch ASAUXSX-SPM EATON SPD Catalogue 4 mm2 25 mm 25 mm 25 mm 2 2 SPCT2-280-3+NPE General arrangement T2 SPCT2-580-3-NPE SPCT2-135-4 SPCT2-175-4 SPCT2-280-4 SPCT2-335-4 SPCT2-385-4 SPCT2-460-4 SPCT2-580-4 580 V / 3 + NPE 135 V 175 V 280 V 335 V 385 V 460 V 580 V / 4 167628 167586 167591 167596 167601 167606 167611 167616 SPCT2-580 SPCT2-135 SPCT2-175 SPCT2-280 SPCT2-335 SPCT2-385 SPCT2-460 SPCT2-580 TN-S TN-S TN-S TN-S TN-S TN-S TN-S TN-S 580 VAC 135 VAC 175 VAC 280 VAC 335 VAC 385 VAC 460 VAC 580 VAC < 2.6 kV < 800 V < 1.0 kV < 1.4 kV < 1.6 kV < 1.8 kV < 2.2 kV < 2.6 kV 2000 V 550 V 700 V 1000 V 1200 V 1350 V 1700 V 2000 V 125 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG 50 kA rms 50 kA rms 50 kA rms 50 kA rms 50 kA rms 50 kA rms 50 kA rms 50 kA rms 580 VAC 580 VAC 135 VAC 175 VAC 350 VAC 415 VAC 415 VAC 580 VAC 1200 VAC - - - - - - - < 25 ns / < 100 ns < 25 ns < 25 ns < 25 ns < 25 ns < 25 ns < 25 ns < 25 ns 100 A rms - - - - - - - - - - - - - - - 3 x 20 kA / 100 kA 20 kA 20 kA 20 kA 20 kA 20 kA 20 kA 20 kA 3 x 40 kA / 100 kA 40 kA 40 kA 40 kA 40 kA 40 kA 40 kA 40 kA IEC 61643 IEC 61643 IEC 61643 IEC 61643 IEC 61643 IEC 61643 IEC 61643 IEC 61643 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 Class II Class II Class II Class II Class II Class II Class II Class II -40oC to +70oC -40oC to + 70oC -40oC to + 70oC -40oC to + 70oC -40oC to + 70oC -40oC to + 70oC -40oC to + 70oC -40oC to + 70oC green (good) / red (replace) green (good)/ red (replace) green (good)/ red (replace) green (good)/ red (replace) green (good)/ red (replace) green (good)/ red (replace) green (good)/ red (replace) green (good)/ red (replace) 4 mm2 4 mm2 4 mm2 4 mm2 4 mm2 4 mm2 4 mm2 4 mm2 2 2 2 2 25 mm 25 mm 25 mm 25 mm 25 mm Quick fastening on DIN rail according to IEC/ EN 60715 Quick fastening on DIN rail according to IEC/ EN 60715 Quick fastening on DIN rail according to IEC/ EN 60715 Quick fastening on DIN rail according to IEC/ EN 60715 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Indoor Indoor 50 / 60 Hz IP40 2 2 2 25 mm2 25 mm 25 mm Quick fastening on DIN rail according to IEC/ EN 60715 Quick fastening on DIN rail according to IEC/ EN 60715 Quick fastening on DIN rail according to IEC/ EN 60715 Quick fastening on DIN rail according to IEC/ EN 60715 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Indoor Indoor Indoor Indoor Indoor Indoor 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz IP40 IP40 IP40 IP40 IP40 IP40 IP40 2 Years 2 years 2 years 2 years 2 years 2 years 2 years 2 years ASAUXSC-SPM ASAUXSC-SPM ASAUXSC-SPM ASAUXSC-SPM ASAUXSC-SPM ASAUXSC-SPM ASAUXSC-SPM ASAUXSC-SPM EATON SPD Catalogue 11 TN-C protection systems Description Bussmann is able to offer a range of SPDs for use within a TN-C system. This is where there is a combined PEN conductor which fulfils the role of the separate PE & N conductors. The modular designs feature integrated fault indication which turns from red to green, visually alerting the operator to whether or not the device has reached the end of its life and needs to be replaced with a new module. Manufactured from thermoplastic, the SPDs are IEC certified for use in environments with an operational temperature range from –40°C to +70°C. Configurations of SPDs can be customised for the application or for the installation location, the module locking system with module release buttons make the replacement easy and without tools by depressing the buttons and lifting the module out. Ordering information T1 T1 / T2 Part numbers SPI-35-440-3 SPBT12-280-3 SPCT2-075-3 SPCT2-135-3 SPCT2-175-3 System voltage/poles 440 V / 3 280/3 75 V/3 135 V/3 175 V/3 Article numbers 267487 158330 167580 167585 167590 Replacement modules - SPBT12-280 SPCT2-075 SPCT2-135 SPCT2-175 Line system type TN-C TN-C TN-C TN-C TN-C Max.continuous operating AC voltage [UC] 440 VAC 280 VAC 75 VAC 135 VAC 175 VAC < 1.0 kV Specifications 12 Voltage protection level [UP] 1.5 kV < 1.5 kV < 550 V < 800 V Voltage protection level at 5kA [UP] - 950 V 400 V 550 V 700 V Max. mains-side overcurrent protection 125 A gL 160 A gL/gG 125A gL/gG 125A gL/gG 125A gL/gG Short circuit withstand capability for max. mains-side overcurrent protection 25 kA rms 50 kA rms 50 kA rms 50 kA rms 50 kA rms Temporary overvoltage test value UT (5 s) 440 VAC 370 VAC 75 VAC 135 VAC 175 VAC Response time (rate of voltage rise 5 kV/ μs) < 100 ns < 25 ns < 25 ns < 25 ns < 25 ns Follow current extinguishing capability [Ifi] 3 kA rms - - - - Lightning impulse current (10/350μs) [limp] 35 kA 12.5 kA - - - Nominal discharge current (8/20μs) In 35 kA 25 kA 15 kA 20 kA 20 kA Max discharge current [Imax] 35 kA 50 kA 30 kA 40 kA 40 kA Standards information IEC 61643 IEC 61643 IEC 61643 IEC 61643 IEC 61643 SPD according to EN 61643-11 Type 1 Type 1 & 2 Type 2 Type 2 Type 2 SPD according to IEC 61643-1 Class I Class I & II Class II Class II Class II Operating temperature range -40oC to +85oC 40oC to +70oC -40oC to + 70oC -40oC to +70oC -40oC to +70oC Operating state/Fault indication - green (good) / red (replace) green (good) / red (replace) green (good) / red (replace) green (good) / red (replace) Cross sectional area (min.) 45 mm2 4 mm2 4 mm2 4 mm2 4 mm2 Cross sectional area (max.) 90 mm 2 Mounting 2 2 2 25 mm 25 mm2 Quick fastening on DIN rail according to IEC/EN 60715 Quick fastening on DIN rail according to IEC/EN 60715 Quick fastening on DIN rail according to IEC/EN 60715 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 25 mm 25 mm Quick fastening on DIN rail according to IEC/EN 60715 Quick fastening on DIN rail according to IEC/EN 60715 Enclosure material Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Location category Indoor Indoor Indoor Indoor Indoor Rated frequency 50 / 60 Hz 50 / 60 Hz 50/60 Hz 50 / 60 Hz 50 / 60 Hz Degree of protection IP40 IP40 IP40 IP40 IP40 Product warranty 2 Years 2 Years 2 years 2 years 2 years Auxiliary switch ASAUXSC-SPM ASAUXSC-SPM ASAUXSC-SPM ASAUXSC-SPM ASAUXSC-SPM EATON SPD Catalogue 52.5 General arrangement SPCT2-280-3 T2 SPCT2-280-3 SPCT2-335-3 SPCT2-385-3 SPCT2-460-3 SPCT2-580-3 280 V/3 335 V/3 385 V/3 460 V/3 580 V/3 167595 167600 167605 167610 167615 SPCT2-280 SPCT2-335 SPCT2-385 SPCT2-460 SPCT2-580 TN-C TN-C TN-C TN-C TN-C 280 VAC 335 VAC 385 VAC 460 VAC 580 VAC < 1.4 kV < 1.6 kV < 1.8 kV < 2.2 kV < 2.6 kV 1000 V 1200 V 1350 V 1700 V 2000 V 125A gL/gG 125A gL/gG 125A gL/gG 125A gL/gG 125A gL/gG 50 kA rms 50 kA rms 50 kA rms 50kA rms 50kA rms 350 VAC 415 VAC 415 VAC 580 VAC 580 VAC < 25 ns < 25 ns < 25 ns < 25 ns < 25ns - - - - - - - - - - 20 kA 20 kA 20 kA 20 kA 20 kA 40 kA 40 kA 40 kA 40 kA 40 kA IEC 61643 IEC 61643 IEC 61643 IEC 61643 IEC 61643 Type 2 Type 2 Type 2 Type 2 Type 2 Class II Class II Class II Class II Class II -40oC to +70oC -40oC to +70oC -40oC to +70oC -40oC to +70oC -40oC to +70oC green (good) / red (replace) green (good) / red (replace) green (good) / red (replace) green (good) / red (replace) green (good) / red (replace) 4 mm2 4 mm2 4 mm2 4 mm2 4 mm2 2 2 2 2 25 mm2 25 mm 25 mm 25 mm 25 mm Quick fastening on DIN rail according to IEC/EN 60715 Quick fastening on DIN rail according to IEC/EN 60715 Quick fastening on DIN rail according to IEC/EN 60715 Quick fastening on DIN rail according to IEC/EN 60715 Quick fastening on DIN rail according to IEC/EN 60715 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Indoor Indoor Indoor Indoor Indoor 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 /60 Hz IP40 IP40 IP40 IP40 IP40 2 years 2 years 2 years 2 years 2 years ASAUXSC-SPM ASAUXSC-SPM ASAUXSC-SPM ASAUXSC-SPM ASAUXSC-SPM EATON SPD Catalogue 13 TT protection systems Description Bussmann is able to offer a selection of IEC certified thermoplastic SPDs for the TT earthing system. The TT system is often used in the telecommunication industry where interference-free earthing is required. One of the main advantages of the TT earthing system is that it is clear of both high and low frequency noises that come through the neutral wire of connected electrical equipment. The modular designs feature integrated fault indication which turns from green to red, visually alerting the operator to whether or not the device has reached the end of its life and needs to be replaced with a new module. Manufactured from thermoplastic, the SPDs are IEC certified for use in environments with an operational temperature range from –40°C to +70°C Ordering information T1 & T2 Part numbers SPBT12-280-2 SPCT2-075-2 SPCT2-135-2 SPCT2-175-2 SPCT2-280-2 SPCT2-335-2 SPCT2-385-2 SPCT2-460-2 System voltage 280 V / 2 75 V 135 V 175 V 280 V 335 V 385 V 460 V Article numbers 158309 167579 167584 167589 167594 167599 167604 167609 Replacement modules SPBT12-280 SPCT2-075 SPCT2-135 SPCT2-175 SPCT2-280 SPCT2-335 SPCT2-385 SPCT2-460 Line system type TT TT TT TT TT TT TT TT Max.continuous operating AC voltage [UC] 280 VAC 75 VAC 135 VAC 175 VAC 280 VAC 335 VAC 385 VAC 460 VAC Specifications 14 Voltage protection level [UP] < 1.5 kV < 550 V < 800 V < 1.0 kV < 1.4 kV < 1.6 kV < 1.8 kV < 2.2 kV Voltage protection level at 5kA [UP] 950 V 400 V 550 V 700 V 1000 V 1200 V 1350 V 1700 V Max. mains-side overcurrent protection 160 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG Short circuit withstand capability for max. mains-side overcurrent protection 50 kA rms 50 kA rms 50 kA rms 50 kA rms 50 kA rms 50 kA rms 50 kA rms 50 kA rms Temporary overvoltage (TOV) UT 370 VAC 75 VAC 135 VAC 175 VAC 350 VAC 415 VAC 415 VAC 580 VAC Response time [tA] < 25 ns < 25 ns < 25 ns < 25 ns < 25 ns < 25 ns < 25 ns < 25 ns Lightning impulse current (10/350μs) [limp] 12.5 kA - - - - - - - Nominal discharge current (8/20μs) In 25 kA 15 kA 20 kA 20 kA 20 kA 20 kA 20 kA 20 kA Max discharge current [Imax] 50 kA 30 kA 40 kA 40 kA 40 kA 40 kA 40 kA 40 kA Standards information IEC 61643 IEC 61643 IEC 61643 IEC 61643 IEC 61643 IEC 61643 IEC 61643 IEC 61643 SPD according to EN 61643-11 Type 1 & 2 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 SPD according to IEC 61643-11 Class I & II Class II Class II Class II Class II Class II Class II Class II Operating temperature range -40oC to +70oC -40oC to + 70oC -40oC to + 70oC -40oC to + 70oC -40oC to + 70oC -40oC to + 70oC -40oC to + 70oC -40oC to + 70oC Operating state/Fault indication green (good) / red (replace) green (good)/ red (replace) green (good)/ red (replace) green (good)/ red (replace) green (good)/ red (replace) green (good)/ red (replace) green (good)/ red (replace) green (good)/ red (replace) Cross sectional area (min.) 4 mm2 4 mm2 4 mm2 4 mm2 4 mm2 4 mm2 4 mm2 4 mm2 Cross sectional area (max.) 25 mm2 25 mm2 25 mm2 25 mm2 25 mm2 25 mm2 25 mm2 25 mm2 Mounting Quick fastening on DIN rail according to IEC/EN 60715 Quick fastening on DIN rail according to IEC/EN 60715 Quick fastening on DIN rail according to IEC/EN 60715 Quick fastening on DIN rail according to IEC/EN 60715 Quick fastening on DIN rail according to IEC/EN 60715 Quick fastening on DIN rail according to IEC/EN 60715 Quick fastening on DIN rail according to IEC/EN 60715 Quick fastening on DIN rail according to IEC/EN 60715 Enclosure material Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Location category Indoor Indoor Indoor Indoor Indoor Indoor Indoor Indoor Rated frequency 50 / 60 Hz 50/60Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz Degree of protection IP40 IP40 IP40 IP40 IP40 IP40 IP40 IP40 Product warranty 2 Years 2 years 2 years 2 years 2 years 2 years 2 years 2 years Auxiliary switch ASAUXSC-SPM ASAUXSC-SPM ASAUXSC-SPM ASAUXSC-SPM ASAUXSC-SPM ASAUXSC-SPM ASAUXSC-SPM ASAUXSC-SPM EATON SPD Catalogue SPCT2-280-2 General arrangement T2 SPCT2-580-2 SPCT2-075-4 SPCT2-135-4 SPCT2-175-4 SPCT2-280-4 SPCT2-335-4 SPCT2-385-4 SPCT2-460-4 SPCT2-580-4 580 V 75 V 135 V 175 V 280 V 335 V 385 V 460 V 580 V / 4 167614 167581 167586 167591 167596 167601 167606 167611 167616 SPCT2-580 SPCT2-075 SPCT2-135 SPCT2-175 SPCT2-280 SPCT2-335 SPCT2-385 SPCT2-460 SPCT2-580 TT TT TT TT TT TT TT TT TT 580 VAC 75 VAC 135 VAC 175 VAC 280 VAC 335 VAC 385 VAC 460 VAC 580 VAC < 2.6 kV < 550 V < 800 V < 1.0 kV < 1.4 kV < 1.6 kV < 1.8 kV < 2.2 kV < 2.6 kV 2000 V 400 V 550 V 700 V 1000 V 1200 V 1350 V 1700 V 2000 V 125 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG 50 kA rms 50 kA rms 50 kA rms 50 kA rms 50 kA rms 50 kA rms 50 kA rms 50 kA rms 50 kA rms 580 VAC 75 VAC 135 VAC 175 VAC 350 VAC 415 VAC 415 VAC 580 VAC 580 VAC < 25 ns < 25 ns < 25 ns < 25 ns < 25 ns < 25 ns < 25 ns < 25 ns < 25 ns - - - - - - - - - 20 kA 15 kA 20 kA 20 kA 20 kA 20 kA 20 kA 20 kA 20 kA 40 kA 30 kA 40 kA 40 kA 40 kA 40 kA 40 kA 40 kA 40 kA IEC 61643 IEC 61643 IEC 61643 IEC 61643 IEC 61643 IEC 61643 IEC 61643 IEC 61643 IEC 61643 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 Class II Class II Class II Class II Class II Class II Class II Class II Class II -40oC to + 70oC -40oC to + 70oC -40oC to + 70oC -40oC to + 70oC -40oC to + 70oC -40oC to + 70oC -40oC to + 70oC -40oC to + 70oC -40oC to + 70oC green (good)/ red (replace) green (good)/ red (replace) green (good)/ red (replace) green (good)/ red (replace) green (good)/ red (replace) green (good)/ red (replace) green (good)/ red (replace) green (good)/ red (replace) green (good)/ red (replace) 4 mm2 4 mm2 4 mm2 4 mm2 4 mm2 4 mm2 4 mm2 4 mm2 4 mm2 25 mm2 25 mm2 25 mm2 25 mm2 25 mm2 25 mm2 25 mm2 25 mm2 25 mm2 Quick fastening on DIN rail according to IEC/EN 60715 Quick fastening on DIN rail according to IEC/EN 60715 Quick fastening on DIN rail according to IEC/EN 60715 Quick fastening on DIN rail according to IEC/EN 60715 Quick fastening on DIN rail according to IEC/EN 60715 Quick fastening on DIN rail according to IEC/EN 60715 Quick fastening on DIN rail according to IEC/EN 60715 Quick fastening on DIN rail according to IEC/EN 60715 Quick fastening on DIN rail according to IEC/EN 60715 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Thermoplastic UL 94 V2 Indoor Indoor Indoor Indoor Indoor Indoor Indoor Indoor Indoor 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz IP40 IP40 IP40 IP40 IP40 IP40 IP40 IP40 IP40 2 years 2 years 2 years 2 years 2 years 2 years 2 years 2 years 2 years ASAUXSC-SPM ASAUXSC-SPM ASAUXSC-SPM ASAUXSC-SPM ASAUXSC-SPM ASAUXSC-SPM ASAUXSC-SPM ASAUXSC-SPM ASAUXSC-SPM EATON SPD Catalogue 15 Remote signalling contact Description 5.5 Bussmann is also able to offer an additional plug in Auxiliary Switch which is designed to be easily installed within each configuration of SPDs on offer. When SPDs are located in different areas of a facility or in hard to reach places, the Auxiliary Switch transmits a signal into the operators computer system to clearly indicate that the specific device needs to be changed when visual identification is not practical. The signalling occurs instantaneously when the device has functioned, providing an up to date status of the system to ensure that the equipment is secure against future strikes. 80 Part numbers ASAUXSC-SPM Article number 131785 Specifications Rated insulation voltage 16 250 VAC Rated frequency 50 / 60 Hz Switching contact 1 CO Minimum voltage per contact 24 VAC Rated operational current AC12 2 A / 250 VAC Maximum back up fuse 2A gL Overvoltage category IV Pollution degree 2 Frame size 45 mm Device height 80 mm Device width 8.8 mm Weight 41 g Mounting DIN rail mounting with screw fixing Degree of protection IP 40 Finger and hand touch safe acc. to BGV A3, ÖVE-EN 6 Upper and lower terminals Lift terminals Terminal capacity 2 x 2.5 mm2 Tightening torque of terminal screws 0.8 - 1 Nm EATON SPD Catalogue 45 44 8.8 60 ASAUXSC-SPM Ordering information 23 General arrangement Lead through terminals Description There are two different Lead Through Terminals available for the range of SPDs (excluding 690 VAC). They permit the orderly wiring of the SPDs and serve to act as a lead through for circuits which require vertical connections from the upper to the lower SPD connection level. The ASLTT-63 is suitable for use alongside all T2 devices and the SPB-D-125 is suitable alongside all T1 devices. Ordering information Part numbers SPB-D-125 ASLTT-63 Article number 248145 131784 Specifications Rated voltage Uc 500 V AC/DC 500 V AC/DC O Rated current IN 125 A / 30 C 63A Peak impulse current (10/350) μs 100 kA - Overvoltage category III - Frame size 45 mm 45 mm Device height 90 mm 90 mm Device width 17.5 mm 17.5 mm Mounting Quick fastening on DIN rail IEC / EN 60715 Quick fastening on DIN rail IEC / EN 60715 Degree of protection IP 40 IP 40 Upper and lower terminals Lift and open-mouthed terminals Lift and open-mouthed terminals Terminal capacity 1 - 25 mm2 (flexible) 1 - 35 mm2 (rigid) 1 - 25 mm2 Tightening torque of terminals screws 4 - 4.5 Nm 2.4 - 3 Nm 5.5 90 17.5 45 43.5 23 80 8.8 45 44 60 58 SPB-D-125 ASLTT-63 EATON SPD Catalogue 17 690 VAC wind and industrial applications Description Bussmann range of 690 VAC surge protection devices are designed specifically for higher voltage industrial applications and installation into wind power applications. Specifically designed for the higher system voltage of wind and industrial applications the 690 VAC SPDs have a high surge discharge capability due to heavy-duty zinc oxide varistor and spark-gap technology; and includes both Type 1 and Type 2 devices for protection against lightning strikes and voltage surges. As well as meeting the requirements of the EN 6164311 standard for low voltage Surge Protection Devices, the 690 VAC SPDs are also vibration and shock resistant according to the EN60068-2 standard making them especially suitable for industrial and wind applications. Ordering information BSPS1690WER T1 T2 Part numbers without remote signaliing BSPS1690WE BSPM1690WE Part numbers with remote signalling BSPS1690WER BSPM1690WER BSPM3690WE BSPM3690WER System voltage/poles 690 V / 1 690 V / 1 690 V / 3 Replacement modules - BPM750WE BPM750WE Line system type TNS, TNC, IT TN, TT TNC Max.continuous operating AC voltage [UC] 760 VAC 600 VAC 600 VAC Voltage protection level [UP] ≤ 4 kV ≤ 3 kV ≤ 3 kV Specifications Voltage protection level at 5kA [UP] - ≤ 2.5 kV ≤ 2.5 kV Max. mains-side overcurrent protection 125 A gL/gG (L-L) 100 A gL/gG 100 A gL/gG Temporary overvoltage test value (TOV) [UT] 1000 V / 5 sec 900 V / 5 sec 900 V / 5 sec Follow current extinguishing capability [Ifi] 25 kA rms 25 kA rms 25 kA rms Lightning impulse current (10/350μs) [limp] 25 kA - - Nominal discharge current (8/20μs) In 25 kA 15 kA 15 kA 25 kA 25 kA IEC 61643 Max discharge current [Imax] 18 Standards information IEC 61643 IEC 61643 SPD according to EN 61643-11 Type 1 Type 2 Type 2 SPD according to IEC 61643-1 Class I Class II Class II Number of poles 1 1 3 Operating temperature range -40oC to +80oC (parallel) -40oC to +60oC (series) -40oC to +80oC -40oC to +80oC Operating state/Fault indication green (good) / red (replace) green (good) / red (replace) green (good) / red (replace) Cross sectional area (min.) 10 mm2 solid / flexible 1.5 mm2 solid / flexible 1.5 mm2 solid / flexible Cross sectional area (max.) 50 mm2 stranded / 35 mm2 flexible 35 mm2 stranded 25 mm2 flexible 35 mm2 stranded 25 mm2 flexible Mounting Quick fastening on DIN rail according to IEC/EN 60715 Quick fastening on DIN rail according to IEC/EN 60715 Quick fastening on DIN rail according to IEC/EN 60715 Enclosure material Thermoplastic UL 94 V0 Thermoplastic UL 94 V0 Thermoplastic UL 94 V0 Location category Indoor Indoor Indoor Degree of protection IP 20 IP 20 IP 20 Product warranty 2 Years 2 Years 2 Years EATON SPD Catalogue Frequently asked questions (FAQs) What is a surge protector? What is an MOV? A surge protector is a device that limits transient overvoltage’s to a safe level, thus protecting equipment it is connected to from damage. A Metal Oxide Varistor is a variable resistor typically made of a large block of zinc oxide grains. They act like semiconductors, an insulator below the conduction voltage and a low value resistor above it. How does an SPD work? In conduction mode, the MOV diverts and dissipates the transient to earth. MOVs generally connect from the line conductors to earth. The thickness of the MOV determines the clamping voltage and diameter determines the current capacity. A surge protector works by momentarily “switching” from an open circuit mode into a low impedance mode and shunting the surge energy to the ground and in doing so, it limits the overvoltage to a safe level. When the surge event is over, the protector returns to its open circuit mode, ready for the next event or if it has reached the end of life then it remains open circuit safely until it is replaced. The visual indicator or remote signalling unit will clearly alert the operator when the SPD has reached the end of life How long does an SPD last? How long an MOV based SPD lasts usually depends upon how often the MOV experiences an overvoltage event and for how long. Every time an MOV switches, its life is degraded. The greater the transient hit, the greater the degradation of the MOV. What is shunting? Shunting is the term used to describe the process by which an SPD redirects voltage transient energy to the ground through a low impedance path. How to size an SPD An SPD size is determined by a variety of factors including geography, electrical environment, cost of downtime and the importance of equipment in operation, amongst others. Call Bussmann to discuss your requirements on +44 (0)1509 882699 EATON SPD Catalogue 19 Eaton is dedicated to ensuring that reliable, efficient and safe power is available when it’s needed most. With unparalleled knowledge of electrical power management across industries, experts at Eaton deliver customized, integrated solutions to solve our customers’ most critical challenges. Our focus is on delivering the right solution for the application. But, decision makers demand more than just innovative products. They turn to Eaton for an unwavering commitment to personal support that makes customer success a top priority. For more information, visit www.eaton.com/electrical. Contact your local Eaton Office Cooper Bussmann (UK) Ltd Melton Road Burton-on-the-Wolds LE12 5TH United Kingdom Tel: +44 (0)1509 882 600 www.bussmann.com Eaton Industries Manufacturing GmbH Electrical Sector EMEA Route de la Longeraie 71110 Morges, Switzerland Eaton.eu © 2014 Eaton All Rights Reserved Printed in the United Kingdom Publication No. BR024003EN February 2014 Changes to the products, to the information contained in this document, and to prices are reserved; so are errors and omissions. Only order confirmations and technical documentation by Eaton is binding. Photos and pictures also do not warrant a specific layout or functionality. Their use in whatever form is subject to prior approval by Eaton. The same applies to Trademarks (especially Eaton, Moeller, and Cutler-Hammer). The Terms and Conditions of Eaton apply, as referenced on Eaton Internet pages and Eaton order confirmations. Eaton is a registered trademark. All other trademarks are property of their respective owners.