ENERGIZER AC10E Zinc Air - Energizer Technical Information

PRODUCT DATASHEET
Asia Pacific Region
+852-31026623
ENERGIZER AC10E
Zinc Air
Specifications
Chemical System:
Tab Color:
Designation:
Nominal Voltage:
Typical Capacity:
(top view) (bottom view)
Industry Standard Dimensions
Typical Weight:
Typical Volume:
(millimeters)
Zinc Air (Zn/O2)
Yellow
IEC-PR70
1.4 Volts
91 mAh (to 0.9 volts)
(Rated at 3k ohms at 21°C/50% RH)
0.32 grams
0.08 cubic centimeters
Impedance
The total opposition that a battery offers to the flow of alternating
current. Impedance is a combination of resistance and reactance.
0.25
Minimum
3.18
3.00
The typical impedance of these cells on open circuit and during
useful discharge varies from 5-20 ohms. This applies over a
frequency range of 40-5,000 hertz at the current drains shown
below.
3.60
3.30
1.35R
Typical
0.015
Typical Coining Depth
5.80
5.60
Impedance vs. Frequency
Typical Discharge Characteristics
Schedule: 16 hours/day
Typical Drain @ 1.3V:
0.43 & 0.22 milliamperes
Load: 3K & 6K ohms
00% DoD
30
25% DoD
25
50% DoD
20
80% DoD
15
10
5
0
1.3
0.1
1.2
1
10
100
1000
Frequency (Hz)
10000
100000
1.1
1.0
Impedance vs. Depth of Discharge
0.9
3K
0.8
0
50
6K
100 150 200 250 300 350 400 450
Service, Hours
Simulated Application Test
Typical Performance at 21°C & 50% RH
Schedule:
16 Hours/Day
16 Hours/Day
25
Typical Drains:
at 1.3V
(milliamperes)
(ohms)
Cutoff
0.9V
(hours)
0.43
0.22
3,000
6,000
211
414
Load
Impedance (ohms)
Operating Voltage
1.4
Impedance (ohms)
35
20
15
40 Hz
10
5
1K Hz
0
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
Depth of Discharge
Important Notice
This datasheet contains typical information specific to products manufactured at the time of its publication.
©Energizer Holdings, Inc. - Contents herein do not constitute a warranty.
Engineering Data
Form No. EBC - 8949AP
Page 1 of 1