Energizer 317 - Energizer Technical Information

PRODUCT DATASHEET
1-800-383-7323
/ USA
+ 44 (0)
208 920 2306
1-800-383-7323
/ CANADA
www.energizer-eu.com
ENERGIZER 317
SILVER OXIDE
Specifications
Industry Standard Dimensions
mm (inches)
Chemical System:
Silver Oxide (Zn/Ag2O)
Nominal Voltage:
Typical Capacity:
Capacity Test:
Typical Weight:
Typical Volume:
Impedance (40 Hz):
1.55 Volts
11.5 mAh* (to 1.2 volts)
68K ohm continuous drain at 21°C
0.17 grams (0.006 oz.)
0.04 cubic centimeters (0.002 cubic inch)
55 to 65 ohms
* Varies according to the applied load, temperature, and cutoff voltage.
3.90 (0.154) Ref.
Typical
5.80 (0.228)
5.65 (0.222)
1.65 (0.065)
Cross Section
1.45 (0.057)
R0.9 (0.035) Ref.
Typical
1.60 (0.063) Ref.
1.40 (0.055) Ref.
Anode Cap
Gel Anode
0.13 (0.005) Minimum Ref.
Permissible deflection from a flat
Gasket
Can
Separator
0.02 (0.001) Minimum Ref.
(applies to top edge of gasket or
edge of crimp, whichever is higher)
Cathode
DESIGNED FOR USE ON CONTINUOUS LOW DRAIN
Typical Discharge Characteristics
Temperature Characteristics
Typical Performance at 21°C (70°F)
Typical Performance at Low Discharge Rates
Service Effects
Service (%)
125
1.7
1.6
1.5
1.4
1.3
1.2
1.1
1.0
100
75
50
25
0
-20
0
20
40
Temperature (C)
0
150
300
450
Service, Hours
Schedule
Typical Drains
at 1.55V
(milliamperes)
(ohm)
Cutoff
1.2V
(hours)
0.023
68K
505
Continuous
Load
Storage Effects
600
100
Service (%)
Voltage, CCV
Schedule: Continuous
Typical Drain @1.55V:
0.023 milliamperes
Load: 68K ohm
0°C
90
20°C
80
70
40°C
60
0
2
4
6
8
Storage Time (yrs)
10
12
Important Notice
This datasheet contains typical information specific to products manufactured at the time of its publication.
©Energizer Holdings, Inc. - Contents herein do not constitute a warranty.
Form No. EBC - 4307G-ZEU
Page 1 of 1