CBI All In One UPS Power Solutions combine the requirements for several
applications in just one device which can be used as power supply unit, battery
charger, battery care module or backup module. The available power is automatically distributed among load and battery, while supplying power to the load
always is the first priority. The maximum available current of the load output is
two times the value of the device’s rated current.
If the device is disconnected from the main power source, the battery will supply
the load until the battery voltage reaches 1.5 V per cell. This prevents the battery
from deep discharge. CBI devices provide microprocessor controlled battery
charging. Using algorithms, the battery’s condition will be detected and based on
that, an appropriate charging mode is chosen. The real-time diagnostics system
will continuously monitor the charging progress and indicate possibly occurring
faults such as elements in short circuit, accidental reverse polarity connection or
disconnection of the battery by the battery fault LED and a flashing code of the
diagnosis LED.
CBI All In One UPS Power Solutions are suitable for open/sealed lead acid-, lead
gel- and optionally Ni-Cd batteries. By using the battery-select-jumper, it is
possible to set predefined charging curves for those battery types. The available
charging options are recovery-, boost- and trickle charge. All CB devices are built
in a rugged metal case with a DIN rail mounting bracket.
Features:
• Power supply, battery charger, battery care module and backup module in one device
• Three charging modes
• Compact, rugged metal case
• Available in 12VDC, 24VDC and 48VDC
• Suitable for most common battery types
• Adjustable charging current
• Easy battery diagnosis and fault identification either by LED or external devices connected
to fault
• Status contacts
• High efficiency up to 91% through switching technology
• Several output protection features such as short circuit, overload, deep battery discharge etc.
• DIN rail mounting
• Small size
• 3 year warranty
C
M
Y
CM
MY
CY
CMY
K
Battery Charging Output
Load Output
Monitor Signal
Switch Contacts
DIN Rail Mounting
Charging Level
Mains LED
Low Battery LED
Diagnosis LED
Battery Start
Push Button
Battery Type
Configuration Jumper
AC Input
2
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000
Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com
CBI_Brochure_Final.pdf
4
3/21/14
CB Series
Battery
Chargers
(pages 12-15)
4:53 PM
With the CB Battery Charger Line, Altech offers a highly reliable battery management
solution. Operating at single phase Input Voltages of 115-230-277 VAC, the devices
supply an Output of 12VDC and up to 35A or 24VDC and up to 20A.
Equipped with microcontrollers, the CB line offers fully automated multi-stage
charging that will expand the battery's life significantly. Several diagnostic and
monitoring features ensure easy handling and a high amount of transparency during
daily operation.
Altech's CB line battery chargers are based on the switching technology which allows
much higher efficiency as well as smaller and lighter devices. Additionally, several
standard safety and protection features ensure safe installation and operation.
Features:
C
M
• Fully automated charging
• Three charging modes
• Compact, rugged metal case
• Available in 12VDC and 24VDC
• Suitable for most common battery types
• Adjustable charging current
• Easy battery diagnosis and fault identification either by LED or external devices connected
to fault status contacts
• High efficiency up to 91% through switching technology
• Several output protection features such as short circuit, overload, deep battery discharge etc.
• DIN rail mounting
• Small size
• 3 year warranty
Y
Fault Status Contacts
CM
MY
CY
DC Output
CMY
DIN Rail Mounting
K
Charging Level
Battery Fault LED
Diagnosis LED
Battery Type
Configuration Jumper
AC Input
Applications for CBI & CB Series:
Acoustic Evacuations
As Mini DC-UPS in industrial applications
Power Supply + Back Up Module
Audio Backup, Lighting Backup, Greenhouse Control, etc.
Automatic Revolving Doors, Access Control, CCTV, Alarms, etc.
Automotive Service Centers, Cars, Motorbikes, etc.
E-Car, Off-Highway Equipment/Machinery, E-Scooter,
Electric Vehicles (on-board chargers)
Emergency Backup
Fire Protection Systems, etc.
Firing System
Forklifts, Scissors Lifts, Pallet Trucks,
Generator Sets (Gen set, Engine Starting, etc.)
Golf Carts, Wheel Chairs, etc.
Industrial Water Pumping
Light Security
Marine Applications
Motorway Light Message Boards
Portable Equipment
Power Supply Continuity
Remote Measurement Station, etc.
Remote measurement stations
Security Doors For Banks
Security Systems
Security Vision Control
Telecommunications
Waterworks Control
Wireless Control
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000
Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com
3
CBI_Brochure_Final.pdf
5
3/21/14
CBI Series
DC-UPS
Solutions
Everything
and more!
• More efficiency of the battery
thanks to continuous control
over time.
• More monitoring in main
connection nodes: input,
output load, battery.
• Event logging: number of
battery charging cycles,
charge cycles completed,
aborted charge cycles, Ah
charged, charging time, total
number of transitions
stand-by /back-up etc...
C
4:53 PM
Power continuity
DC-UPS = Power Supply +
Smart battery management
Battery Charger + Back Up module Load output will not be affected by
Double Output, Optimized Power Man
agement. Thanks to the DC-UPS units,
it will be possible to smart-manage
available power. It will be automatically
allocated between load and battery.
Supplying power to the load is the first
priority of the unit; thus it is not neces
sary to double the power, and also the
power available for the battery will go to
the load if the load requires so.
Output Load:
Power Boost:
12, 24, 48
In x 2 Continuous
In x 3 max 4 sec.
Battery
Avoid deep battery discharge
• Event Management: checking
the load output, shutdown
management of PCs
(UPS function), RESET
management of a generic
equipment.
CM
MY
CY
In case of mains failure, the battery will
supply the load until battery voltage
reaches 1.5 Vpc (Volt per cell).
Below this level the device automatically
switches off to prevent deep discharge
and battery damage.
CMY
• Flexibility of use: customization of the entire charging
curve of the battery, battery
type setting, setting of the
various time-out algorithms of
charge, setting boost voltage,
absorption, float, etc...
configuration as DC-UPS
or batteries charger, enabling
power supply function .
K
Load
Load
M
Y
battery conditions. The DC-UPS insures
continuous power supply to the load
even in conditions of completely
discharged batteries. The automatic
multi-stage operation optimizes and
adapts to the battery status. DCUPS can recharge deeply discharged
batteries even when their voltage is
close to zero, thus allowing recharge
and complete recovery of flat batteries.
In Power Boost mode the maximum
current on the load output is the 2
times the rated current (2 x In) in
continuous operation and 3 times
the rated current (3 x In) for max. 4
seconds.
In
2 In
3 In
Load
In
In
I batt
In
I batt
> 4 min.
I batt
max. 4 sec.
Time buffering
Time buffering is enabled when in
back-up mode. Buffering time setting is
possible by operating the rotary switch
on the front panel.
Adjustable maximum
battery charging current
The maximum battery charging current
can be set from 10% to 100% of the
device rated value.
TIME BUFFERING
4
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000
Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com
CBI_Brochure_Final.pdf
6
3/21/14
4:53 PM
CBI Series
DC-UPS
Solutions
Connection & monitoring
Start from battery without main
Monitor signals
Accessories
If you want to restart the system while
the mains is off, a battery restart
function is available, via RTCONN cable
connections, or via pushbutton in the
front panel.
Clear definition of each system operation, via LED indications and Relay
contact:
All DC-UPS units can be made available
with the following options by RJ45 or
RJ11 connector:
Contact Port signals, galvanic
insulation
■ Main or back-up signaling relay with
voltage-free. NO-NC output terminals.
■ Battery faulty signaling relay, relay
with voltage-free. NO-NC output
terminals.
■ Flat battery signaling relay, relay with
voltage-free. NO-NC output terminals.
Temperature sensor Probe, for ambient
temperature compensation charging.
Start from battery
Voltage drop cable compensation.
+ Batt.
C
M
Y
CM
Battery Start UP cable.
Wide input voltage range
Flexibility is given also by the wide
range input voltage. The range of the
devices accept input voltage 120 - 230 277 - 400 - 500 VAC.
Display Signals by LED
■ Input Main On Off
■ Battery Fault
■ Low battery (capacity less than 30%)
■ Type of Battery charge mode
■ Help through “blinking code” the
diagnosis of the system
MY
CY
CMY
K
Input ity
flexibil
Auxiliary output “Aux 2
and "Aux 3”
MODBUS and CANBUS connection
for Multimedia management, for
connection to external displays and
perform customized data monitoring.
Connection to:
• Power View App
• Power View System
• Power Bus
• Power View Graphic
• Power View Bar Graph
• Power View Config
One device for output
12 or 24 VDC
You can select the voltage between
12 or 24 VDC just before installing the
device in your panel (available on selected
products in the new Altech DC-UPS units).
24
12
C
VD
Driver Contact
Remote link for selection of trickle/
boost charging Via RTCONN remote
connections cable it is possible to drive
the devices from Boost - Bulk to Trickle Float charge. It is also possible to
permanently install a jumper for Boost Bulk Charging.
AUX 2
AUX 3
C
VD
Boost flat charge
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000
Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com
5
3/21/14
CBI Series
DC-UPS
Solutions
C
M
Y
CM
MY
These devices are completely
automatic and can charge any kind of
battery using factory pre-set charging
curves suitable to the most common
battery technologies: open lead acid,
sealed lead acid, lead gel, Ni-Cd and
Ni-MH. These devices are very
flexible and can be customized to
meet the needs of the user and the
requirements of the application. After
the installation, it is possible to carry
out functional software updates just
using any laptop computer. Doing so,
your system can always be updated
to changing requirements. The
Battery Care concept is base on
algorithms that implement rapid and
automatic charging, battery charge
optimization during time, flat
batteries recovery and real time
diagnostic during installation and
operation. Battery faults such as
battery sulfated, elements in short
circuit, accidental reverse polarity
connection can easily be detected,
identified and removed. The All in one
Series meet the highest standards of
quality and insure high reliability, with
MTBF values up to 300.000 hours.
4:53 PM
Battery care
One device for all battery types
All devices are suitable to charge most
batteries types thank to user selectable
charging curves. They can charge open
lead acid, sealed lead acid, Gel, Ni-Cd,
Ni-MH, Li Ion batteries. It is possible
to change or add other charging curves
connecting the device to a portable PC.
Charging mode is then completely
automatic.
Open Lead Acid (factory preset):
Trickle 2.23 V
Boost 2.40 V
Sealed Lead Acid (1):
Trickle 2.25 V
Boost 2.40 V
Multi-Stage charging - Four
charging modes
Automatic multi-stage operation
and real time diagnostic allows fast
recharge and recovery of deeply
discharged batteries, adding value and
reliability to the system hosting the
DC-UPS device. The type of charging
is Voltages stabilized and Current
stabilized IUoU. CBI battery chargers
feature four charging modes, identified
by a flashing code on a LED.
■ Recovery (5 Blinks / sec) able to
recharge batteries even when their
voltage is close to zero.
■ Boost - Bulk (2 Blinks / sec).
■ Absorption (1 Blinks / sec).
■ Trickle - Float (1 Blink / 2 sec).
AGM Sealed Lead Acid (2):
Trickle 2.27 V
Boost 2.40 V
Gel:
Trickle 2.30 V
Boost 2.40 V
Recovery
charge
(blink 5/sec.)
Optional: Ni/Cd, LI-Ion
CY
Charge
Absorbtion
Absorption
7
Boost
CBI_Brochure_Final.pdf
Trickle /
Float Charge
(blink 1/sec.)
CMY
Boost or flat charge
K
Start from battery
Battery Life Test
Battery type confi guration jumper
L
N
PE
Diagnosis of battery and device
All CBI devices support the user during
installation and operation. A LED flash
ing sequence code allows to discrimi
nate among various possible faults.
Error conditions, LED Fault ON and LED
Diagnosis flashing with sequence of:
■ 1 flash = Reverse polarity, wrong
battery voltage
■ 2 flashes= Disconnected battery
■ 3 flashes = Battery element in short
circuit
Boost or float charge.
■ 4 flashes = Overload
■ 5 flashes = Battery to be replaced
(Internal impedance Bad or Bad
battery wire connection)
6
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000
Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com
CBI_Brochure_Final.pdf
8
3/21/14
4:53 PM
CBI Series
DC-UPS
Battery care
Solutions
Battery Life Test
Diagnostic checks
Max. safety and protection
It guarantees battery reliability in
time by continuously testing the
internal impedance status. It avoids
any possible risk of damages and
grants also a permanent, reliable
and safe connection of the battery
to the power supply. The system,
through a battery stimulation circuit
with algorithms of evaluation of
the detected parameter, is able to
recognize sulfated batteries or
batteries with a short-circuited cell.
Check for accidental disconnection
of the battery cables.
DC-UPS detects accidental
disconnection and immediately
switches off output power.
The DC-UPS series is designed to
provide safe operation and long power
supply and battery life. The following
protections are standard features:
C
M
Y
CM
Battery not connected
If the battery is not connected the
battery output is disabled.
Test of wire connection impedance
During trickle charge the resistance
on the battery connection is checked
every 20 sec. This to detect if the
cable connection has been properly
made.
Battery in open circuit or sulfated
Every four hours DC-UPS tests of
internal impedance, while in trickle
charging mode.
All protections have automatic reset.
No thermal fuse to be replaced.
Reverse polarity check
If the battery it is connected
with inverted polarity, DC-UPS is
automatically protected.
Robust construction and
easy installation
All the units in the range have aluminum
casing, DIN rail fastening clip and are
light and compact. IP20 protection
degree.
MY
CY
CMY
K
Temperature Compensation
In special application like fire fighting
equipment, you can recharge the
battery also with the temperature
compensation charging function, for
the best condition of your battery in
the temperature fluctuation.
• Outputs protected against short circuit
and overload
• Outputs in conformity to SELV and
PELV conditions
• High insulation between primary and
secondary
• Protection against deep battery
discharge
• Protection against reverse polarity
connection
• Detection of batteries with wrong
rated voltage
Test of battery voltage connections
Appropriate voltage check, to prevent
connection of wrong battery types.
End of charge check
When the battery it is completely full,
the device automatically switches to
trickle charging mode.
Check for battery cells in short circuit
Thanks to specific testing algorithms,
the DC-UPS recognize batteries with
cells in internal short circuit.
Element in
Short Circuit
Technology
The new DC-UPS range is based on two
strategic know-how elements. Switching
technology, we have 25 years of
experience in design of advanced
stabilized switching technology power
supplies. A power supply/battery charger
unit based on this technology is much
more efficient.
Back UP Module and Battery Care units,
unlike most other state-of-the-art battery
chargers, the DC-UPS series is equipped
with complex algorithms which controls
the charging process and enable several
monitoring functions. The firmware
implements the extended battery care
know-how, result of many years of
experience in this field.
Norms In Conformity to:
• IEC/EN 60335-2-29 Battery chargers;
• EN60950 / UL60950;
• Electrical safety EN54-4 Fire
Detection and fire alarm systems;
• EMC Directive;
• DIN 41773 (Charging cycle)
C
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000
Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com
US
UL60950
7
CBI_Brochure_Final.pdf
9
3/21/14
4:53 PM
CBI Series
DC-UPS
In VAC
12 VDC
Battery
Mains or Backup
Battery Low or
Battery Replacement
Out load
INPUT
DATA
OUTPUT
DATA
INPUT
DATA
Input voltage range
Output VDC / IN
Efficiency (50% of In)
12VDC - 3A - 36W
Input voltage range
90 - 305 VAC
Frequency
47 - 63 Hz ±6%
Output VDC / IN
12VDC - 3A
Efficiency (50% of In)
90%
Over load and short-circuit protection
■
Over load and short-circuit protection
Overheating thermal protection
■
Overheating thermal protection
Reverse battery protection
■
Reverse battery protection
Output voltage (at IN) VDC
Output voltage (at at IN) VDC
10 - 14.4VDC
Nominal current IN = Iload
Nominal current IN = Iload
1.1 x In A ± 5%
Continuous current (without battery) Iload = In
Continuous current (without battery) Iload = In
3A
Max current (with battery) Out: Iload = In + Ibatt
Max current (with battery) Out: Iload = In + Ibatt
6A
Max current (main input) Out: Iload (4sec.)
Max current (main input) Out: Iload (4sec.)
9A max
Max current output load: (Back Up) Iload (4sec.)
Max current output load: (Back Up) Iload (4sec.)
6A max
Push button or remote input control
■
Push button or remote input control
Time Buffering
Time Buffering
Boost-Bulk charge (Typ. at IN)
Boost-Bulk charge (Typ. at IN)
14.4VDC
Max. time boost-bulk charge (Typ. at IN)
Max. time boost-bulk charge (Typ. at IN)
15h
Min. time boost-bulk charge (Typ. at IN)
Min. time boost-bulk charge (Typ. at IN)
1min.
Trickle-Float charge (Typ. at IN)
Trickle-Float charge (Typ. at IN)
13.8VDC
Charging current Limiting IN (Iadj)
Charging current Limiting IN (Iadj)
20 ÷ 100 % / Ibatt
MY
CY
CLIMATIC
DATA
GENERAL
DATA
OPTIONAL
K
AUXILIARY SIGNAL
OUTPUT* OUTPUT
FOR:
(RELAY)
CMY
8
12VDC - 6A - 72W
90 - 305 VAC
90 - 305 VAC
47 - 63 Hz ±6%
47 - 63 Hz ±6%
12VDC - 3A
12VDC - 6A
90%
90%
■
E353188
CBI126A
CBI1210A
12VDCCBI1210A
- 6A - 72W
12VDCCBI1235A
- 10A - 120W
CBI1235A
12VDC - 35A - 420W
■
■
12VDC - 10A - 120W
12VDC - 35A - 420W
90 - 135 VAC
90 - 305 VAC
90 - 305
90VAC
- 135 VAC
180 - 305 VAC
90 - 305 VAC
180 - 305 VAC
47 - 63 Hz ±6%
47 - 63 Hz ±6%
47 - 63 Hz ±6%
47 - 63 Hz ±6%
47 - 63 Hz ±6%
12VDC - 6A
12VDC - 10A
12VDC - 35A
12VDC - 10A
12VDC - 35A
90%
90%
> 91%
90%
> 91%
■
■
■
■
■
■
■
■
■
■
■
10 - 14.4VDC
10 - 14.4VDC
1.1 x In A ± 5%
1.1 x In A ± 5%
3A
6A
6A
12A
9A max
18A max
6A max
12A max
-
■
■
■
■
■
10 - 14.4VDC
10 - 14.4VDC
1.1 x In A ± 5%
1.1 x In A ± 5%
6A
10A
12A
20A
18A max
30A max
12A max
20A max
■
-
■
■
■
■
■
10 - 14.4VDC
10 - 14.4VDC
1.1 x In A ± 5%
1.1 x In A ± 5%
10A
35A
20A
70A
30A max
105A max
20A max
70A max
■
-
10 - 14.4VDC
1.1 x In A ± 5%
35A
70A
105A max
70A max
■
■
■
BATTERY CHARGER
OUTPUT
CM
AUXILIARY SIGNAL
OUTPUT* OUTPUT
FOR: (RELAY)
Y
Main or backup power
Main or backup power
■
■
Low battery and fault battery
■
Low battery and fault battery
Temp. charging probe
Temp. charging probe
by ext. Probe
UPS active
UPS active
Modbus - CAN Bus
Modbus - CAN Bus
Ambient temperature operation
Ambient temperature operation
-25 ÷ +70°C
De rating Tª > (In) / De rating Tª > (In)
De rating Tª > (In) / De rating Tª > (In)
> 50° -2.5%(In) / °C
Ambient temperature storage
Ambient temperature storage
-40 ÷ +85°C
Humidity at 25 °C
Humidity at 25 °C
95% to 25°C
Cooling
Cooling
Auto Convection
Isolation voltage (IN / OUT)
Isolation voltage (IN / OUT)
3000VAC
Isolation voltage (IN / PE)
Isolation voltage (IN / PE)
1605VAC
Isolation voltage (OUT / PE)
Isolation voltage (OUT / PE)
500VAC
Protection class (EN/IEC 60529)
Protection class (EN/IEC 60529)
IP 20
Reliability (MTBF IEC 61709)
Reliability (MTBF IEC 61709)
> 300 000 h
Dimension (w-h-d)
Dimension (w-h-d)
65x115x135
Safety standard approval
Safety standard approval
CE /C-UL Recognized 60950
Bar graph control panel
Bar graph control panel
Graphic multifunction control panel
Graphic multifunction control panel
System monitoring software
System monitoring software
System configuration software
System configuration software
Interface module modbus 485 - Ethernet
Interface module modbus 485 - Ethernet
Interface module cloud all in one - Ethernet
Interface module cloud all in one - Ethernet
Battery temp. compensation Probe RJTemp
■
Battery temp. compensation Probe RJTemp
CLIMATIC
DATA
BATTERY CHARGER
OUTPUT
M
E353188
■
14.4VDC
14.4VDC
14.4VDC
14.4VDC
14.4VDC
14.4VDC
14.4VDC
15h
15h
15h
15h
15h
15h
15h
1min.
1min.
1min.
1min.
1min.
1min.
1min.
13.8VDC
13.8VDC
13.8VDC
13.8VDC
13.8VDC
13.8VDC
13.8VDC
20 ÷ 100 % / Ibatt
20 ÷ 100 % / Ibatt
20 ÷ 100 % / Ibatt
10 ÷ 100 % / Ibatt
20 ÷ 100 % / Ibatt
20 ÷ 100 % / Ibatt
10 ÷ 100 % / Ibatt
2.23 V/cell Open Lead, 2.25 V/cell Sealed Lead, 2.27 V/cell Sealed Lead, 2.3 V/cell gel;
Jumper config. type battery (NiCd optional)
2.23 V/cell Open Lead, 2.25 V/cell Sealed Lead,
V/cell(10
Sealed
Lead,
2.3(Imax
V/cell10%)
gel;
NiCd2.27
1.5V/cell
elem.)
trickle
Jumper config. type battery (NiCd optional)
NiCd 1.5V/cell (10 elem.) trickle (Imax 10%)
Remote input control (AMP Type connector)
Boost / Trickle
Boost / Trickle
Boost / Trickle
Boost / Trickle
Remote input control (AMP Type connector)
Boost / Trickle
Boost / Trickle
Boost / Trickle
Boost / Trickle
Characteristic Curve
IUoU, Automatic, 4 stage
Characteristic Curve
IUoU, Automatic, 4 stage
GENERAL
DATA
C
CBI123A
12VDCCBI126A
- 3A - 36W
■
■
■
■
■
■
■
by ext. Probe
by ext. Probe
-25 ÷ +70°C
-25 ÷ +70°C
> 50° -2.5%(In) / °C
> 50° -2.5%(In) / °C
-40 ÷ +85°C
-40 ÷ +85°C
95% to 25°C
95% to 25°C
Auto Convection
Auto Convection
3000VAC
3000VAC
1605VAC
1605VAC
500VAC
500VAC
IP 20
IP 20
> 300 000 h
> 300 000 h
65x115x135
65x115x135
CE /C-UL Recognized 60950
■
■
■
■
■
■
by ext. Probe
by ext. Probe
by ext. Probe
by ext. Probe
■
-25 ÷ +70°C
-25 ÷ +70°C
-25 ÷ +70°C
-25 ÷ +70°C
> 50° -2.5%(In) / °C
> 50° -2.5%(In) / °C
> 50° -2.5%(In) / °C
> 50° -2.5%(In) / °C
-40 ÷ +85°C
-40 ÷ +85°C
-40 ÷ +85°C
-40 ÷ +85°C
95% to 25°C
95% to 25°C
95% to 25°C
95% to 25°C
Auto Convection
Auto Convection
Auto Convection
Auto Convection
3000VAC
3000VAC
3000VAC
3000VAC
1605VAC
1605VAC
1605VAC
1605VAC
500VAC
500VAC
500VAC
500VAC
IP 20
IP 20
IP 20
IP 20
> 300 000 h
> 300 000 h
> 300 000 h
> 300 000 h
65x115x135
65x115x135
65x115x135
150x115x135
CE /C-UL Recognized 60950
CE /C-UL Recognized 60950
CE
OPTIONAL
LOAD
OUTPUT
LOAD
OUTPUT
OUTPUT
DATA
CBI123A
Output
Output
Frequency
E353188
Model
Model
by ext. Probe
■
-25 ÷ +70°C
> 50° -2.5%(In) / °C
-40 ÷ +85°C
95% to 25°C
Auto Convection
3000VAC
1605VAC
500VAC
IP 20
> 300 000 h
150x115x135
CE
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000
Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com
■
■
CBI_Brochure_Final.pdf
10
3/21/14
4:53 PM
CBI Series
DC-UPS
24 VDC
CBI243A
24VDC - 3A - 72W
E353188
CBI245A
24VDC
CBI243A 5A - 120W
24VDC - 3A - 72W
90 - 305 VAC
47 - 63 Hz ±6%
24VDC - 3A
90%
90 - 305 VAC
90 - 305 VAC
47 - 63 Hz ±6%
47 - 63 Hz ±6%
24VDC - 5A
24VDC - 3A
90%
90%
■
1.1 x In A ± 5%
3A
6A
9A max
6A max
M
Y
CM
28.8VDC
15h
1min.
27.6VDC
20 ÷ 100 % / Ibatt
MY
CY
Boost / Trickle
CMY
K
CBI2420A
24VDC - 10A - 240W
90 - 135 VAC
90 - 180
135 -VAC
305 VAC
180 - 305 VAC
47 - 63 Hz ±6%
47 - 63 Hz ±6%
24VDC - 20A
24VDC - 10A
> 91%
83%
24VDC - 20A - 500W
90 - 135 VAC
90 - 180
135 -VAC
305 VAC
180 - 305 VAC
47 - 63 Hz ±6%
47 - 63 Hz ±6%
48VDC - 5A
24VDC - 20A
83%
> 91%
■
■
48VDC - 5A - 240W
90 - 135 VAC
90 - 180
135 -VAC
305 VAC
180 - 305 VAC
47 - 63 Hz ±6%
47 - 63 Hz ±6%
48VDC - 10A
48VDC - 5A
> 91%
83%
■
■
■
■
■
■
■
22 - 28.8VDC
22 - 28.8VDC
1.1 x In A ± 5%
1.1 x In A ± 5%
5A
3A
10A
6A
15A max
9A max
10A max
6A max
22 - 28.8VDC
22 - 28.8VDC
1.1 x In A ± 5%
1.1 x In A ± 5%
10A
5A
20A
10A
30A max
15A max
20A max
10A max
■ CBI2410A/S
22 - 28.8VDC
22 - 28.8VDC
1.1 x In A ± 5%
1.1 x In A ± 5%
20A
10A
40A
20A
60A max
30A max
40A max
20A max
44 - 57.6VDC
22 - 28.8VDC
1.1 x In A ± 5%
1.1 x In A ± 5%
5A
20A
10A
40A
15A max
60A max
10A max
40A max
■ CBI485A/S
44 - 57.6VDC
44 - 57.6VDC
1.1 x In A ± 5%
1.1 x In A ± 5%
10A
5A
20A
10A
30A max
15A max
20A max
10A max
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
by ext. Probe
by ext. Probe
by ext. Probe
by ext. Probe
by ext. Probe
-25 ÷ +70°C
-25 ÷ +70°C
-25 ÷ +70°C
-25 ÷ +70°C
-25 ÷ +70°C
> 50° -2.5%(In) / °C
> 50° -2.5%(In) / °C
> 50° -2.5%(In) / °C
> 50° -2.5%(In) / °C
> 50° -2.5%(In) / °C
-40 ÷ +85°C
-40 ÷ +85°C
-40 ÷ +85°C
-40 ÷ +85°C
-40 ÷ +85°C
95% to 25°C
95% to 25°C
95% to 25°C
95% to 25°C
95% to 25°C
Auto Convection
Auto Convection
Auto Convection
Auto Convection
Auto Convection
3000VAC
3000VAC
3000VAC
3000VAC
3000VAC
1605VAC
1605VAC
1605VAC
1605VAC
1605VAC
500VAC
500VAC
500VAC
500VAC
500VAC
IP 20
IP 20
IP 20
IP 20
IP 20
> 300 000 h
> 300 000 h
> 300 000 h
> 300 000 h
> 300 000 h
65x115x135
65x115x135
100x115x135
65x115x135
65x115x135
CE /C-UL Recognized 60950
CE
CE /C-UL Recognized 60950
CE /C-UL Recognized 60950
■
■
■
by ext. Probe
by ext. Probe
-
by ext. Probe
by ext. Probe
-
by ext. Probe
by ext. Probe
-
■
-25 ÷ +70°C
-25 ÷ +70°C
> 50° -2.5%(In) / °C
> 50° -2.5%(In) / °C
-40 ÷ +85°C
-40 ÷ +85°C
95% to 25°C
95% to 25°C
Auto Convection
Auto Convection
3000VAC
3000VAC
1605VAC
1605VAC
500VAC
500Vac
IP 20
IP 20
> 300 000 h
> 300 000 h
150x115x135
100x115x135
CE
CE
-25 ÷ +70°C
-25 ÷ +70°C
> 50° -2.5%(In) / °C
> 50° -2.5%(In) / °C
-40 ÷ +85°C
-40 ÷ +85°C
95% to 25°C
95% to 25°C
Auto Convection
Auto Convection
3000VAC
3000VAC
1605VAC
1605VAC
500VAC
500VAC
IP 20
IP 20
> 300 000 h
> 300 000 h
100x115x135
150x115x135
CE
CE
-
■
15h
1min.
55.2VDC
10 ÷ 100 % / Ibatt
Boost / Trickle
by ext. Probe
-25 ÷ +70°C
> 50° -2.5%(In) / °C
-40 ÷ +85°C
95% to 25°C
Auto Convection
3000VAC
1605VAC
500VAC
IP 20
> 300 000 h
150x115x135
CE
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
57.6
■
■
■
■
■
■
■
20A max
■
■
-25 ÷ +70°C
-25 ÷ +70°C
> 50° -2.5%(In) / °C
> 50° -2.5%(In) / °C
-40 ÷ +85°C
-40 ÷ +85°C
95% to 25°C
95% to 25°C
Auto Convection
Auto Convection
3000VAC
3000VAC
1605VAC
1605VAC
500VAC
500VAC
IP 20
IP 20
> 300 000 h
> 300 000 h
150x115x135
100x115x135
CE
CE
■
■
30A max
■
■
■
20A
■
■
■
10A
■
■
-
1.1 x In A ± 5%
■
■
■
44 - 57.6VDC
■
■ CBI485A/S
■
■
■
28.8VDC
28.8VDC
28.8VDC
57.6
57.6
28.8VDC
28.8VDC
28.8VDC
28.8VDC
57.6
15h
15h
15h
15h
15h
15h
15h
15h
15h
15h
1min.
1min.
1min.
1min.
1min.
1min.
1min.
1min.
1min.
1min.
27.6VDC
27.6VDC
27.6VDC
55.2VDC
55.2VDC
27.6VDC
27.6VDC
27.6VDC
27.6VDC
55.2VDC
20 ÷ 100 % / Ibatt
20 ÷ 100 % / Ibatt
10 ÷ 100 % / Ibatt
20 ÷ 100 % / Ibatt
10 ÷ 100 % / Ibatt
20 ÷ 100 % / Ibatt
20 ÷ 100 % / Ibatt
20 ÷ 100 % / Ibatt
10 ÷ 100 % / Ibatt
20 ÷ 100 % / Ibatt
2.23 V/cell Open Lead, 2.25 V/cell Sealed Lead, 2.27 V/cell Sealed Lead, 2.3 V/cell gel;
2.23NiCd
V/cell1.5V/cell
Open Lead,
2.25
V/cell
Sealed Lead, 2.27 V/cell Sealed Lead, 2.3 V/cell gel;
trickle
(Imax
10%)
NiCd 1.5V/cell trickle (Imax 10%)
Boost / Trickle
Boost / Trickle
Boost / Trickle
Boost / Trickle
Boost / Trickle
Boost / Trickle
Boost / Trickle
Boost / Trickle
Boost / Trickle
Boost / Trickle
IUoU, Automatic, 4 stage
IUoU, Automatic, 4 stage
-
-
■
> 91%
■
■
■ CBI2410A/S
48VDC - 10A
■
■
■
47 - 63 Hz ±6%
■
■
■
90 - 135 VAC
180 - 305 VAC
■
■
■
48VDC - 10A - 500W
■
■
■
■
CBI4810A
48VDC - 10A - 500W CBI4810A
CBI485A
■
■
■
■
CBI485A
24VDC - 20A - 500W CBI2420A
48VDC - 5A - 240W
CBI2410A
■
■
-
47 - 63 Hz ±6%
47 - 63 Hz ±6%
24VDC - 10A
24VDC - 5A
83%
90%
■
■
C
24VDC - 5A - 120W
90 - 135 VAC
305 V AC
90 - 180
305 -VAC
■
■
■
22 - 28.8VDC
E353188
CBI2410A
24VDC
CBI245A 10A - 240W
■
■
■
48 VDC
■
■
■
■
■
■
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000
Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com
■
9
CBI_Brochure_Final.pdf
11
3/21/14
4:53 PM
CBI Series
DC-UPS
In VAC
36/48 VDC
12/24 VDC
12/24 VDCdc
Battery
Mains or Backup
Battery Low or
Battery Replacement
Out load
CBI2803648A
Model
LOAD
OUTPUT
OUTPUT
DATA
INPUT
DATA
Output
C
MY
CY
BATTERY CHARGER
OUTPUT
CM
CMY
12/24VDC - 270W
Input voltage range
90 - 135 VAC
180 - 305 VAC
90 - 135 VAC
180 - 305 VAC
180 - 264 VAC
330 - 550 VAC
Frequency
47 - 63 Hz ±6%
47 - 63 Hz ±6%
47 - 63 Hz ±6%
Output VDC / IN
36 / 48VDC - 270 W
12 / 24VDC - 270 W
12 / 24VDC - 270 W
Efficiency (50% of In)
> 91%
> 91%
> 91%
Over load and short-circuit protection
■
■
■
Overheating thermal protection
■
■
■
Reverse battery protection
■
■
■
Output voltage (at IN) VDC
33 - 43,2VDC /
44 - 57.6VDC
11 - 14.4VDC /
22 - 28.8VDC
11 - 14.4VDC /
22 - 28.8VDC
Nominal current IN = Iload
1.1 x In A ± 5%
1.1 x In A ± 5%
1.1 x In A ± 5%
Continuous current (without battery) Iload = In
7A (36V) / 5A (48V)
15A (12V) / 10A (24V)
15A (12V) / 10A (24V)
Max current (with battery) Out: Iload = In + Ibatt
14A (36V) / 10A (48V)
30A (12V) / 20A (24V)
30A (12V) / 20A (24V)
Max current: (main input) Out: Iload (4sec.)
21A (36V) / 15A (48V)
45A (12V) / 30A (24V)
45A (12V) / 30A (24V)
Max current output load: (Back Up) Iload (4sec.)
14A (36V) / 10A (48V)
30A (12V) / 20A (24V)
30A (12V) / 20A (24V)
Push button or remote input control
■
■
■
Time Buffering
■
■
■
Boost-Bulk charge (Typ. at IN)
43.2VDC (36V) /
57.6VDC (48V)
14.4 VDC (12V) /
28.8VDC (24V)
14.4 VDC (12V) /
28.8VDC (24V)
Max. time boost-bulk charge (Typ. at IN)
15h
15h
15h
Min. time boost-bulk charge (Typ. at IN)
1min.
1min.
1min.
Trickle-Float charge (Typ. at IN)
41.4VDC (36V) /
55.2VDC (48V)
13.8 VDC (12V) /
27.6VDC (24V)
13.8 VDC (12V) /
27.6VDC (24V)
Charging current Limiting IN (Iadj)
10 ÷ 100 % / Ibatt
10 ÷ 100 % / Ibatt
10 ÷ 100 % / Ibatt
2.23 V/cell Open Lead, 2.25 V/cell Sealed Lead, 2.27 V/cell Sealed Lead, 2.3 V/cell gel;
NiCd 1.5V/cell (20 elem.) trickle (Imax 10%)
Jumper config. type battery (NiCd optional)
Remote input control (AMP Type connector)
K
Boost / Trickle
Boost / Trickle
AUXILIARY SIGNAL
OUTPUT* OUTPUT
FOR:
(RELAY)
CLIMATIC
DATA
GENERAL
DATA
OPTIONAL
Boost / Trickle
IUoU, Automatic, 4 stage
Characteristic Curve
10
CBI2801224B
12/24VDC - 270W
M
Y
CBI2801224A
36/48VDC - 270W
Main or backup power
■
■
Low battery and fault battery
■
■
■
Temp. charging probe
by ext. Probe
by ext. Probe
by ext. Probe
UPS active
-
-
-
Modbus - CAN Bus
■
■
■
Ambient temperature operation
-25 ÷ +70°C
-25 ÷ +70°C
-25 ÷ +70°C
De rating Tª > (In) / De rating Tª > (In)
> 50° -2.5%(In) / °C
> 50° -2.5%(In) / °C
> 50° -2.5%(In) / °C
Ambient temperature storage
-40 ÷ +85°C
-40 ÷ +85°C
-40 ÷ +85°C
■
95% to 25°C
95% to 25°C
95% to 25°C
Cooling
Auto Convection
Auto Convection
Auto Convection
Isolation voltage (IN / OUT)
3000Vac
3000Vac
3000Vac
Isolation voltage (IN / PE)
1605Vac
1605VAC
1605VAC
Isolation voltage (OUT / PE)
500VAC
500VAC
500VAC
Protection class (EN/IEC 60529)
IP 20
IP 20
IP 20
Reliability (MTBF IEC 61709)
> 300 000 h
> 300 000 h
> 300 000 h
Dimension (w-h-d)
115x115x135
115x115x135
115x115x135
Safety standard approval
CE
CE
CE
Bar graph control panel
■
■
■
Graphic multifunction control panel
■
■
■
System monitoring software
■
■
■
System configuration software
■
■
■
Interface module modbus 485 - Ethernet
■
■
■
Interface module cloud all in one - Ethernet
■
■
■
Battery temp. compensation Probe RJTemp
■
■
■
Humidity at 25 °C
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000
Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com
CBI_Brochure_Final.pdf
12
3/21/14
4:53 PM
Battery
Enclosures
Small VRLA
Compact and fully enclosed improve
safety and maintenance, transmit
information on the temperature and
type of batteries. They save space
and improve the efficiency of the DC
UPS “All In One”.. Size for 24 VDC: 1.2
Ah, 3 Ah, 7.2 Ah and 12 Ah.
24 VDC
BAT1.2 VRLA
Model
OUTPUT
DATA
INPUT
DATA
Output
24V - 1.2Ah
BAT3.4 VRLA
24V - 7.2Ah
BAT12 VRLA
24V - 12Ah
27.5 VDC (20°C) ; 27 VDC (30°C); 26.5 VDC (40°C)
End-of-charge voltage (trickle charge)
Max. permissible charging current
0.30 A
0.80 A
1.70 A
Short-circuit protection
■
■
■
■
Protection fuse
25 A
25 A
25 A
25 A
Output current
max. 25 A
max. 25 A
3A
max. 25 A
max. 25 A
DIN Rail / Wall Mount
Mounting position
for hanging onto M4 screws
Assembly using 4 holes
GENERIC
DATA
BAT7.2 VRLA
24V - 3.2Ah
Ambient temperature (operation)
0 ÷ +40 °C
0 ÷ +40 °C
0 ÷ +40 °C
0 ÷ +40 °C
Ambient temperature (storage)
-20 ÷ +50 °C
-20 ÷ +50 °C
-20 ÷ +50 °C
-20 ÷ +50 °C
20 °C 15% per month
Self-discharge rate
Dimension (w-h-d)
62 x 175 x 120
82 x 200 x 160
145 x 210 x130
210 x 210x210
Weight
1.5Kg approx
3 Kg approx
5.5 Kg approx.
9 Kg
Protection class
IP20
IP20
IP20
IP20
C
M
Y
CM
MY
Battery Selection Chart
CY
CMY
BUFFERING
(MINUTE) TIME
K
Battery type
1.2 Ah
3.2 Ah
7.2 Ah
12 Ah
Load 1.5 A
20
60
200
400
Load 3 A
8
30
120
240
Load 5 A
3
15
55
100
Load 7.5 A
2
10
30
60
Load 10 A
-
7
20
45
Load 12 A
-
3
12
30
Load 15 A
-
-
9
20
Load 20 A
-
-
7
13
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000
Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com
11
CBI_Brochure_Final.pdf
13
3/21/14
4:53 PM
CB Series
Battery
Chargers
One device for all
battery types
Completely automatic, the battery chargers of the
CB series are microprocessor
controlled devices suited to charging most batteries
types thank to factory pre-set and selectable
charging curves. They can charge open lead acid,
sealed lead acid, Gel and Ni-Cd, Ni-MH batteries. It
is possible to change or add other charging curves
connecting the device to a portable PC.
Multi-Stage charging Three charging modes
Automatic multi-stage operation and
real time diagnostic allow fast recharge
and recovery of deep discharged
batteries, adding value and reliability to
the system hosting the CB device. The
type of charging it is Voltages stabilized
and current stabilized IUoUo. CB
battery chargers feature three charging
modes, identified by a flashing code on
a LED.
Recovery charging
Automatic multi-stage operation
optimizes and adapt to battery status, even
when the battery voltage is very low. CB
can recharge batteries even when their
voltage is close to zero. It allows recharge
and complete recovery of flat batteries.
Typical charging curve for
recovery of batteries with
voltage close to zero.
• Boost (Boost - Bulk) (Blink 2/sec)
• Trickle (also known as fl oat or maintenance
charging) (Trickle - Float) (Blink 1/Sec.)
• Recovery (Recovery) (Blink 5/sec.)
Recovery
(blink 5/sec.)
Trickle - Float
(blink 1/sec.)
Jumper positions / VpC:
Setting of battery maximum charging
current
The maximum battery charging current
can be set from 20% to 100% of the
device rated value. Not available on LC
models.
• Open Lead Acid:
Trickle 2.23V
Boost 2.40V
• Sealed Lead Acid (1):
Trickle 2.25V
Boost 2.40V
C
M
Y
Boost - Bulk
(blink 2/sec.)
• Sealed Lead Acid (2):
Trickle 2.27
Boost 2.40V
CM
MY
Diagnosis
• Gel:
Trickle 2.30V
Boost 2.40V
CY
CMY
K
• Optional:
Ni/Cd
Diagnosis
Diagnosis
Jumper for
Battery Type
Selection
Diagnostic of battery
and device
All CB devices support the user during
installation and operation. An LED
flashing sequence code allows to
discriminate among various possible
faults.
LED Diagnosis:
• 1 flash
Reverse polarity, wrong battery voltage.
• 2 flashes
Disconnected battery.
• 3 flashes
Battery element in short circuit.
• 5 flashes
Battery to be replaced (Internal
impedance Bad or Bad battery
wire connection).
Diagnosis
Diagnosis
C
12
US
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000
Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com
14
3/21/14
CB Series
Battery
Chargers
Monitor signals
Wide range input voltage
Technology
Flexibility is given also by the wide range input
voltage. All the devices of the CB range accept
input voltage in the range of 120 - 230 - 277 VAC.
Only one device to stock!
The CB series is a new range of battery
chargers based on two strategic
know-how elements.
120 VAC
flexibility
AC
0V
23
277
Signal contacts
• CB chargers indicate battery
status and faults also via a
change-over contact with
galvanic isolation.
• Battery common fault.
• Unit disconnected from mains.
4:53 PM
VAC
CBI_Brochure_Final.pdf
Diagnostic checks
C
M
Visual indication
• Battery common fault
• Unit disconnected from mains
• Charging mode
• CB device self-diagnostic
Y
CM
Diagnosis
• Check for accidental disconnection of the
battery cables. If happen the devices
switch off immediately the output power.
• Battery not connected. If the battery it is
not connected no output power.
MY
CY
• Test of quality wire connections.
During trickle charge the quality
(resistance) on the battery connection is
checked every 20 sec. This to detect if the
cable connection has been properly made.
CMY
K
Single output devices
• Test of battery voltage connections.
Appropriate voltage check, to prevent
connection of wrong battery types.
Diagnosis
• End of charging check. When the battery
it is completely full, the device automatically
switch in trickle charging mode.
• Reverse polarity check. If the battery it is
connected with inverted polarity, the
devices are automatically protected.
Element in
Short Circuit
Switching technology
We have over 25 year experience in
design of advanced stabilized switching
technology power supplies. A battery
charger based on this technology is much
more efficient and much smaller
and lighter than traditional linear technology battery chargers.
Micro-processor and Battery Care
Unlike most other state-of-the-art battery
chargers, the CB series is equipped with a
micro-processor
which controls the charging process
and enables several monitoring functions.
The firmware implements
the extended battery care know-how,
result of many years of experience in this
field.
Maximum safety
and protection
The CB series is designed to provide
safe operation and long battery
life. The following protections are
standard features:
• Output protected against short circuit
and overload
• Protection against deep battery
discharge
• Protection against reverse polarity
connection
• High insulation between primary
and secondary
• Detection of batteries with wrong
rated voltage
• Protection against the effect of parallel
connection with other power sources,
e.g. gensets.
All protections have automatic reset.
No thermal fuse to be replaced.
Diagnosis
Test and Diagnosis
of the battery
• Check for elements in short circuit.
Thanks to specific algorithms of
evaluation, the CBs recognize batteries
with element in short circuit.
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000
Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com
13
CBI_Brochure_Final.pdf
15
3/21/14
4:53 PM
CB Series
Battery
Chargers
12 VDC
E353188
INPUT
DATA
2xVAC
OUTPUTS
DATA
CB123A
CB126A
CB1210A
CB1235 A
Input (Volt) VAC
115-230-277
115-230-277
115-230-277
115-230-277
Output (VDC - A - W)
12 - 3 - 36
12 - 6 - 72
12 - 10 - 120
12 - 35 - 420
Model
CB123A
CB126A
CB1210A
CB1235A
Input Voltage Range VAC
90 - 264
90 - 264
90 - 264
90 - 135 / 180 - 264
Inrush Current (Vn and In Load) I2t (msec)
≤ 11 A ≤ 5
≤ 11 A ≤ 5
≤ 16 A ≤ 5
≤ 35 A ≤ 5
Frequency
47 - 63 Hz ± 6%
47 - 63 Hz ± 6%
47 - 63 Hz ± 6%
47 - 63 Hz ± 6%
Input Current (115 - 230 VAC)
0,5 - 0.3 A
1 - 0.7 A
2.4 - 1.2 A
8 - 4.2 A
Internal Fuse
4A
4A
4A
10 A
External Fuse (recommended)
10 A
10 A
10 A
16 A
Output VDC / IN
12 VDC 3 A
12 VDC 6 A
12 VDC 10 A
12 VDC 35 A
> 81%
> 81%
> 89%
> 91%
Boost - Bulk charge (Typ. at IN)
14.4 VDC
14.4 VDC
14.4 VDC
14.4 VDC
Max.Time Boost-Bulk charge (Typ. at IN)
15 h
15 h
15 h
15 h
Min.Time Boost-Bulk charge (Typ. at IN)
70 min.
70 min.
1 min.
1 min.
Trickle-Float charge (Typ. at IN)
13.75 VDC
13.75 VDC
13.75 VDC
13.75 VDC
Recovery Charge
2 - 7 VDC
2 - 7 VDC
2 - 9 VDC
2 - 9 VDC
Charging max Ibatt
3 A ± 5%
6 A ± 5%
10 A ± 5%
35 A ± 5%
Minimum load
Efficiency (50% of IN)
Short-circuit protection
Over Load protection
Over Voltage Out protection
Reverse battery protection
C
M
BATTERY
CHARGER
OUTPUT
Y
CM
MY
CY
Charging current Limiting IN (Iadj)
2.23 V/cell Open Lead, 2.25 V/cell Sealed Lead, 2.27 V/cell Sealed Lead, 2.3 V/cell gel
Jumper Config. Type Battery
CMY
Quiescent Current
K
≤ 5 mA
≤ 5 mA
≤ 5 mA
IUoUo, Automatic 3 stage
≤ 5 mA
Characteristic Curve
SIGNAL
OUTPUT
(RELAY)
Main or Backup Power
Low Battery and Fault Battery
Main or Backup - Fault Battery
AUXILIARY
RJ45
OUTPUT
FOR:
Temp. Charging probe
CLIMATIC
DATA
Ambient Temperature (operation)
-25 - +70 °C
-25 - +70 °C
-25 - +70 °C
-25 - +70 °C
De rating Tª > . (In)
> 50° 2.5%
> 40° 2.5%
> 50° 2.5%
> 50° 2.5%
Voltage drop compensation
Remote monitoring display
> 40 °C
Automatic De rating
GENERAL
DATA
14
Ambient Temperature Storage
-40 - +85 °C
-40 - +85 °C
-40 - +85 °C
-40 - +85 °C
Humidity at 25 °C, no condensation
95% to 25 °C
95% to 25 °C
95% to 25 °C
95% to 25 °C
Cooling
Auto Convection
Auto Convection
Auto Convection
Auto Convection
Insulation Voltage (IN/OUT)
3000 VAC
3000 VAC
3000 VAC
3000 VAC
Insulation Voltage (IN/PE)
1605 VAC
1605 VAC
1605 VAC
1605 VAC
Insulation Voltage (OUT/PE)
500 VAC
500 VAC
500 VAC
500 VAC
Protection Class (EN/IEC 60529)
IP 20
IP 20
IP 20
IP 20
Reliability: MTBF IEC 61709
> 300 000 h
> 300 000 h
> 300 000 h
> 300 000 h
Pollution Degree Environment
2
2
2
2
Connection Terminal Blocks Screw Type
2,5 mm
2,5 mm
2,5 mm
4 mm
Protection class (with PE connected)
I
I
I
I
Dimension (w-h-d)
45x100x100
45x100x100
65x115x135
150x115x135
Weight
0.30 kg approx
0.30 kg approx
0.65 kg approx
1.5 kg approx
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000
Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com
CBI_Brochure_Final.pdf
16
3/21/14
4:53 PM
CB Series Battery Chargers
24 VDC
12/24 VDC
E353188
E353241
CB243A
CB245A
CB2410A
CB2420A
115-230-277
115-230-277
115-230-277
115-230-277
CB12245A
115-230-277
24 - 3 - 72
24 - 5 - 120
24 - 10 - 240
24 - 20 - 500
12/24 – 6/5 – 120
CB243A
CB245A
CB2410AC
CB2420A
CB12245A
90 - 264
90 - 264
90 - 135 / 180 - 264
90 - 135 / 180 - 264
90-305
≤7A≤5
≤ 16 A ≤ 5
≤ 16 A ≤ 5
≤ 35 A ≤ 5
<-16A; 5ms
47 - 63 Hz ± 6%
47 - 63 Hz ± 6%
47 - 63 Hz ± 6%
47 - 63 Hz ± 6%
47-63 Hz +-6%
1 - 0.7 A
2.4 - 1.2 A
3.3 - 2.2 A
8 - 4.2 A
2.4-1.2-1.0 A
4A
4A
6.3 A
10 A
4A
10 A
10 A
16 A
16 A
10A (MCB – curve B)
24 VDC 3 A
24 VDC 5 A
24 VDC 10 A
24 VDC 20 A
12VDC -6A / 24VDC-5A
> 81%
> 89%
Connection Diagram
In VAC
Battery
Mains or Backup
Battery Low or
Battery Replacement
CB123A, CB1210A
90%
In VAC
Battery
Mains or Backup
Battery Low or
Battery Replacement
C
28.8 VDC
28.8 VDC
28.8 VDC
28.8 VDC
14.4VDC / 28.8VDC
M
15 h
15 h
15 h
15 h
15 h
Y
70 min.
1 min.
1 min.
1 min.
4 min.
27.5 VDC
27.5 VDC
27.5 VDC
27.5 VDC
13.75 VDC / 27.5 VDC
2 - 16 VDC
2 - 18 VDC
2 - 18 VDC
2 - 18 VDC
2-7 / 2-16 VDC
3 A ± 5%
5 A ± 5%
10 A ± 5%
20 A ± 5%
6A / 5A ± 5%
CM
MY
CB1235A
In
Battery
Mains or Backup
Battery Low or
Battery Replacement
CB243A,
CY
2.23 V/cell Open Lead, 2.25 V/cell Sealed Lead, 2.27 V/cell Sealed Lead, 2.3 V/cell gel
CMY
K
≤ 5 mA
≤ 5 mA
≤ 5 mA
≤ 5 mA
≤ 5 mA
In VAC
Battery
IUoUo, Automatic, 3 stage
Mains or Backup
Battery Low or
Battery Replacement
CB245A, CB2410A, CB2420A
-25 - +70 °C
-25 - +70 °C
-25 - +70 °C
-25 - +70 °C
-25 - +70 °C
> 50° 2.5%
> 50° 2.5%
> 50° 2.5%
> 50° 2.5%
> 40° 2.5%
-40 - +85 °C
-40 - +85 °C
-40 - +85 °C
-40 - +85 °C
-40 - +85 °C
95% to 25 °C
95% to 25 °C
95% to 25 °C
95% to 25 °C
95% to 25 °C
Auto Convection
Auto Convection
Auto Convection
Auto Convection
Auto Convection
3000 VAC
3000 VAC
3000 VAC
3000 VAC
3000 VAC
1605 VAC
1605 VAC
1605 VAC
1605 VAC
1605 VAC
500 VAC
500 VAC
500 VAC
500 VAC
500 VAC
IP 20
IP 20
IP 20
IP 20
IP 20
> 300 000 h
> 300 000 h
> 300 000 h
> 300 000 h
> 300 000 h
2
2
2
2,5 mm
2,5 mm
2,5 mm
I
I
I
45x100x100
65x115x135
100x115x135
150x115x135
45x105x100
0.30 kg approx
0.65 kg approx
0.85 kg approx
1.55 kg approx
0.35 kg approx
> 40 °C
2
4 mm
I
2
2,5 mm
I
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000
Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com
Optional for Auxiliary Output (RJ
45 connection) Temp. Charging
probe: Temperature Sensor for
battery 2 m length; Safety