SHS - Altech

Technical Data
Safety switches
Safety Hinge Switch SHS
Total operating range
Illustration with fixed shaft and sheared-off set screw.
Position of the connection variants 2, 5 and 6.
Position of the connection variants 1, 3 and 4.
Connection variant 1
Connection variant 2
Connection variant 3
Cable, PVC
Cable, PVC
Plug M12x1, metal thread
Connection variant 4
Connection variant 5
Connection variant 6
Plug M12x1, metal thread,
with manipulation guard
Plug M12x1,
Plastic thread
Plug M12x1, metal thread
This document does not form the basis of a contract. The information contained therein does not describe expected properties, thereby excluding the possibility of
defect liability arising from any deviations between the actual properties and those described here.
We reserve the right to make changes.
Date of issue: 21.12.2007 / Page 1 of 4
Document: 7100001_en / Status: 6 / 2801-07
Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica / www.bernstein-ag.de
Vorlage : 0850174285 Orig. 1
Article number
Description
Connection variant
Contact type
Operating diagram
Voltage type
Surface / colour
Protection class
EC-Type
Examination
Certificate
Technical Data
Safety switches
6019261011
SHS-A1Z-KA 5
1
1 N.C. contact
A
AC/DC
galvanised / blue
I
BG
6019261014
SHS-A1Z-KR 5
2
1 N.C. contact
A
AC/DC
galvanised / blue
I
BG
6119261005
SHS-A1Z-KR 5
2
1 N.C. contact
A
AC/DC
Finish: RAL 9006
(white aluminium)
I
BG
6019261009
SHS-A1Z-SA
3
C
AC/DC
galvanised / blue
I
-
6019261010
SHS-A1Z-SR
5
B
DC
galvanised / blue
SELV
-
6019261015
SHS-A1Z-SA
3
B
DC
galvanised / blue
SELV
-
6019261016
SHS-A1Z-SR
6
C
AC/DC
galvanised / blue
I
-
6019261017
SHS-A1Z-SA-BG
4
1 N.C. contact
D
AC/DC
galvanised / blue
I
BG
6019261018
SHS-A1Z-SR-BG
6
1 N.C. contact
D
AC/DC
galvanised / blue
I
BG
1 Change over
contact
1 Change over
contact
1 Change over
contact
1 Change over
contact
Operating diagram
1 N.C. contact
(Form B)
Circuit diagram
1 Change over contact
(Form C)
A
B
GNYE
Fixing point
Fixing point
On Off
C
D
On Off
Fixing point in the range 0° ... 180° freely selectable
Tolerance, switching angle (opening) +2,0 ° / -1,5 °
Tolerance, direct opening torque 10 %
Tolerance, direct opening angle +0,5 ° / -3 °
Switching angle hysteresis (closing the N.C. contact –1,0 °) from the hinge’s typical switch-off point
This document does not form the basis of a contract. The information contained therein does not describe expected properties, thereby excluding the possibility of
defect liability arising from any deviations between the actual properties and those described here.
We reserve the right to make changes.
Date of issue: 21.12.2007 / Page 2 of 4
Document: 7100001_en / Status: 6 / 2801-07
Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica / www.bernstein-ag.de
Vorlage : 0850174285 Orig. 1
Technical Data
Safety switches
Common characteristic data
The characteristic data refers to SHS with a fixed switching point.
The data marked also applies to the empty hinges (see Page 4).
Electrical data
Rated insulation voltage
Rated impulse withstand voltage
Conv. thermal current
Rated operational voltage
Utilization category
Direct opening action
Short-circuit protection device
Ui
Uimp
Ithe
Ue
Mechanical data
Enclosure
Cover
Wing
Ambient air temperature
Mechanical life
Switching frequency
Attachment
Connection type (connection variant 1, 2)
(connection variant 3, 4, 5, 6)
Weight
Installation position
Protection type
Switching angle
Direct opening angle
Direct opening torque
Mechanical load
(see dimensioned drawing for the introduction direction of the forces)
Standards
250 V
2,5 kV
3A
230 V AC / 60 V DC
AC-15, 230 V AC / 1,5 A, DC-13, 60 V DC / 0,5 A
nach IEC/EN 60947-5-1, Anhang K
fusible link 4 A gL/gG
GD-Zn
GD-Zn
GD-Zn
-25 °C to +70 °C (cable securely laid)
106 operating cycles
Max. 1200 switching operations / hour
4 x M6 screws DIN 7984 or DIN 6912
Fixed connecting cable 3 x 0,5 mm² x 5 m (AWG20)
Minimum bending radius = 25 mm
M12 plug
approx. 0,7 kg (variant 1, 2)
approx. 0,4 kg (variant 3, 4, 5 and empty hinge)
Any
IP 67 in acc. with IEC/EN 60529
+/- 3 ° from fixing point
+/- 10 ° from fixing point
1,5 Nm
FR1= max. 1000 N
FR2= max. 500 N
FA = max. 750 N
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1
VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1
EU conformity
Approvals
BG (see overview)
C300
CCSAUS
This document does not form the basis of a contract. The information contained therein does not describe expected properties, thereby excluding the possibility of
defect liability arising from any deviations between the actual properties and those described here.
We reserve the right to make changes.
Date of issue: 21.12.2007 / Page 3 of 4
Document: 7100001_en / Status: 6 / 2801-07
Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica / www.bernstein-ag.de
Vorlage : 0850174285 Orig. 1
Technical Data
Safety switches
Notes
The safety fixture must always be attached by at least two SHS! See max. load.
If the risk assessment of the machine permits a single-channel evaluation, an empty hinge (see below) can be
used as the support element.
If the SHS is used at an ambient temperature of 70 °C, it is possible that the connecting cable will age more
rapidly!
The connecting cable must be protected against mechanical damage.
The cable can be installed in tubes or cable ducts.
The electrical connection for a SHS with BG inspection certificate is only permitted with the following cable
couplings (Bernstein range; cable length: 5 m):
3251103234 (with straight plug) or 3251103236 (with angled plug)
In the case of 6019261018, the fastening nut of the connecting cable coupling must be in a closed
area after assembly that can only be opened with a tool (manipulation guard; e.g. hollow profile,
machine stand, frame,...).
The manufacturer / supplier of the machine / system is obligated to observe the applicable standards for the size
of the safety intervals between the separating safety fixture and the hazard point.
These regulations include: EN 294, EN 349, EN 953, EN 1088, ... .
The switch may not be used as a stop.
For a CSA/UL application it is essential to use CSA/UL approved cable for connection versions 3,5 and 6.
The suggested protection type (IP code), referred to the connection variants 3, 4, 5 and 6, applies only when at
least an equivalent cable coupling is used.
Empty hinge SHS
Total operating range
Swivel frequency:
Swivel angle:
Article number
6019291013
6119291006
Description
SHS-0Z
SHS-0Z -9006-
max. 1200/hour
0 ° to 180 °
Surface / colour
Galvanised: blue passivated
Finish: RAL 9006 (white aluminium)
The mechanical data corresponds to the safety hinge switches (see Page 3, identification ).
This document does not form the basis of a contract. The information contained therein does not describe expected properties, thereby excluding the possibility of
defect liability arising from any deviations between the actual properties and those described here.
We reserve the right to make changes.
Date of issue: 21.12.2007 / Page 4 of 4
Document: 7100001_en / Status: 6 / 2801-07
Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica / www.bernstein-ag.de
Vorlage : 0850174285 Orig. 1