Technical Data Safety switch

Technical Data
Safety switch
Series SK – with separate actuator
SK-U1Z M
Description
Article number
6016119016
Operating symbol
Operating diagram
Actuator
withdrawn
inserted
ON
OFF
Tolerances
Operating point: ± 0,25mm;
Actuating force: ± 10%
Electrical data
Rated insulation voltage
Conv. thermal current
Utilization category
Direct opening action
Short-circuit protective device
Protection class
Ui
Ithe
250 VAC
10A
AC-15, Ue /Ie 240V/3A
according to IEC/EN 60947-5-1, Annex K
Fuse 10A gL/gG
II, totally insulated
This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims
for defects on account of possible variations of the actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications
subject to change without notice!
Date of issue: 16.01.2006 / Page 1 of 2
Document : 6016119016_en / Last update: 1 / 2043-06
Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica / www.bernstein-ag.de
Vorlage : 0850174285 Orig. 2
Technical Data
Safety switch
Mechanical data
Enclosure
Cover
Actuator
Extraction force
Ambient air temperature
Contact type
Mechanical life
Switching frequency
Assembly
Safety switch
Actuator
Connection
Conductor cross-sections
Cable entrance
Weight
Installation position
Protection type
Thermoplastic, glass fibre reinforced (UL94-V0)
Thermoplastic, glass fibre reinforced (UL94-V0)
Separate actuator (St – stainless steel)
10N
-30°C … +80°C
1 NC, 1 NO (Zb)
1 x 106 switch operations
≤ 30 / min.
2 x M5
2 x M5
4 screw connections (M3,5)
Solid: 0,5 ... 1,5mm²
Litz wire with ferrules: 0,5 ... 1,5mm²
3 x M20 x 1,5
≈ 0,13kg
Operator definable
IP65 acc. to IEC/EN 60529
Actuation
Turning the cap (pos A/B) allows 4 different directions of drive.
Cover (1) has to be opened before turning the cap (2).
Insert the screwdriver into the gap between housing and cap and
turn until the cap snaps off.
Remove the cap, turn it 180° (4), latch it into the housing and
close the cover.
Standards
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1
VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1
GS-ET 15
EU Conformity
Approvals
BG
CCSAUS A300 (same polarity)
Notes
The degree of protection (IP code) specified applies solely to a property closed cover and the use of an
equivalent cable gland with adequate cable.
The switch may not be used as a mechanical stop.
Radial actuation may reduce the mechanical life.
The min. radius refers to a pivot at the top of the cap (S0).
Tapped holes not in use must be closed with blind plugs.
This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims
for defects on account of possible variations of the actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications
subject to change without notice!
Date of issue: 16.01.2006 / Page 2 of 2
Document : 6016119016_en / Last update: 1 / 2043-06
Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica / www.bernstein-ag.de
Vorlage : 0850174285 Orig. 2