Technical Data Safety switch Series ASI-SLK – with separate actuator Description Article number ASI-SLK-F-R1-A0-0 Position monitoring of guard Electromagnet with contact position 6073200058 The actuator is not included in the scope of delivery. It can be ordered separately. without current Electromagnet with current Operating diagram Actuator withdrawn Actuator inserted ON OFF Tolerances Actuating force: ± 15 % Electrical data Protection class Contact elements Direct opening action Electro magnets Auxiliary supply Duty cycle Temperature class Inrush power consumption Permanent power consumption Switch operations permanent II, totally insulated according to IEC/EN 60947-5-1, Annex K DC 24 V +10 %/-15 % 100 % ED F (155 °C) 12 VA (0,2 s) 4,4 VA 600/h This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims for defects on account of possible variations of the actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications subject to change without notice! Date of issue: 12.12.2012 / Page 1 of 3 Document : 6073200058_en.doc / Last update: 2 / 2560-12 Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica / www.bernstein.eu Vorlage : 0850174285 Orig. 2 Technical Data Safety switch AS-Interface Data Operating voltage Operating current AS-i Specifications U I AS-i Inputs AS-i Outputs Parameter bits AS-i Address Mechanical data Enclosure Cover Actuating head Actuator Minimum actuating radius Velocity for actuating Extraction force Interlocking principle Unlocking Hold on force Ambient air temperature Contact type Mechanical life Assembly Connection Plug connection Weight Installation position Protection type Rmin Vmax FZh 26,5 … 31,6 V; via AS-interface, reverse-polarity proof < 50mA Profil S-7.B IO-Code: 0x7 ID-Code: 0xB ID-Code1: 0xF ID-Code2: 0xE Actuator contact: Date bits D0/D1 = static 00 or dynamic code transmission Locking contact: Date bits D2/D3 = static 00 or dynamic code transmission D0 Electromagnet, 1 = Magnet with curent D1 LED 4 green, 1 = LED on* D2 LED 5 green, 1 = LED on* D3 * 1 = D1 and D2 control LED 4 and LED 5 0 = D1 and D2 no function LED 4 = actuator LED 5 = locking no function preset address: 0 Thermoplastic GV (UL94-V0) Thermoplastic GV (UL94-V0) Thermoplastic GV / Zn-GD Separate actuator (St / PA) see separate actuators data sheet 0,5m/s ≥ 27 N Spring force Magnetic force ≤ 1500 N acc. to GS-ET-19 -25 °C ... +60 °C 1 NC (slow break contact element) 1 x 106 switching cycles (at max. 600 switch operations / h) 4 x M5 Plug connection M12 male 1: AS-i + 2: auxiliary supply 0V 3: AS-i 4: auxiliary supply 24V ≈ 0,34 kg operator definable IP67 acc. to IEC/EN 60529 This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims for defects on account of possible variations of the actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications subject to change without notice! Date of issue: 12.12.2012 / Page 2 of 3 Document : 6073200058_en.doc / Last update: 2 / 2560-12 Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica / www.bernstein.eu Vorlage : 0850174285 Orig. 2 Technical Data Safety switch Actuation 4 different actuating directions achievable by rotating the actuating head. Changing between horizontal and vertical actuating direction by setting the actuating head in the requested direction. Standards VDE 0660 T100, DIN EN 60947-1, IEC 60947-1 VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1 GS-ET-19, EN 50295, EN ISO 13849-1 EU Conformity acc. To Directive 2004 / 108 / EC Safety Classification according 13849-1 to PL e MTTFd = high PFD = 2,49 * 10-10 Approvals TÜV NORD Notes The degree of protection specified (IP code) applies only to a properly closed cover and the use of an equivalent connector The switch may not be used as a mechanical stop. When power is removed from the electromagnet (solenoid) the safety guard will be in locked position. This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims for defects on account of possible variations of the actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications subject to change without notice! Date of issue: 12.12.2012 / Page 3 of 3 Document : 6073200058_en.doc / Last update: 2 / 2560-12 Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica / www.bernstein.eu Vorlage : 0850174285 Orig. 2