Technical Data Rope pull switch

Technical Data
Rope pull switch
Series SIEK
Description
Article number
SIEK-UV1Z
6011831134
Operating symbol
Operating diagram
(pretensioned installation)
ON
OFF
Tolerance
tensile force: ± 15 %
Electrical data
Rated insulation voltage
Conv. thermal current
Rated operational voltage
Utilization category
Direct opening action
Short-circuit protective device
Protection class
Ui
Ithe
Ue
400 V AC
10 A
240 V
AC-15, Ue /Ie 240 V / 3 A
acc. to IEC/EN 60947-5-1, Annex K
Fuse 10 A gL/gG
II, totally insulated
This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims
for defects on account of possible variations of the actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications
subject to change without notice!
Date of issue: 11.09.2009 / Page 1 of 2
Document: 6011831134_en.doc / Last update: 1 / 2439-09
Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica, Germany / www.bernstein.eu
Vorlage : 0850174284 Orig. 2
Technical Data
Rope pull switch
Mechanical data
Enclosure
Cover
Actuator
Ambient air temperature
Contact type
Mechanical life
Switching frequency
Assembly
Connection
Conductor cross-sections
Cable entrance
Weight
Installation position
Protection type
Standards
Thermoplastic, glass fibre reinforced
Thermoplastic, glass fibre reinforced
Pull ring (Zn-die cast; rotatable, without stop)
-30 °C ... +80 °C
1 NC, 1 NO (Zb)
1 x 106 operating cycles
≤ 50 / min.
4 x M5
4 screw terminals (M3,5)
Solid: 0,5 ... 1,5 mm²
Litz wire with ferrules: 0,5 ... 1,5 mm²
1 x M20x1,5
≈ 0,17 kg
Operator definable
IP65 acc. to IEC/EN 60529
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1
VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1
EU Conformity
Approvals
CCSAUS
A300 (same polarity)
Notes
The degree of protection (IP code) specified applies solely to a property closed cover and the use of an
equivalent cable gland with adequate cable.
This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims
for defects on account of possible variations of the actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications
subject to change without notice!
Date of issue: 11.09.2009 / Page 2 of 2
Document: 6011831134_en.doc / Last update: 1 / 2439-09
Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica, Germany / www.bernstein.eu
Vorlage : 0850174284 Orig. 2