Technical Data

Technical Data
Safety switch
Series SLM – with separate actuator
Description
Article number
SLM-FVTW24DC-55-AR
Position monitoring
of guard locking
Position monitoring
of electromagnet
Operating diagram
Termination
electromagnet
6017119020
Actuator
withdrawn
Actuator
inserted
ON
OFF
Tolerances
Actuating force: ± 15%
Electrical data
Protection class
Contact elements
Rated insulation voltage
Rated impulse withstand voltage
Conv. thermal current
Utilization category
Direct opening action
Short-circuit protective device
Electro magnets
Duty cycle
Temperature class
Power consumption P20
Operating voltage
I
Ui
Uimp
Ithe
250 V
2,5 kV
5A
AC-12, Ue /Ie 250 V / 10 A
AC-15, Ue /Ie 230 V / 4 A
according to IEC/EN 60947-5-1, Annex K
10A gL/gG
100 % ED (at E1; E2)
B (130 °C)
5,2 W
24 V DC
This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims
for defects on account of possible variations of the actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications
subject to change without notice!
Date of issue: 11.01.2007 / Page 1 of 2
Document : 6017119020_en / Last update: 2 / 2010-07
Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica / www.bernstein-ag.de
Vorlage : 0850174285 Orig. 2
Technical Data
Safety switch
Mechanical data
Enclosure
Cover
Actuating head
Actuator
Minimum actuating radius
Velocity for actuating
Extraction force
Interlocking principle
Unlocking
Rmin
Vmax
Hold on force
FZh
Ambient air temperature
Contact type
Switching principle
Mechanical life
Assembly
Connection
Conductor cross-sections solid
finely stranded with ferrules
Cable entrance
Weight
Installation position
Protection type
AI-GD
AL-sheet
Zn-GD
Separate actuator (St / PA)
400 mm
1,5 m/s
≥ 30 N
Spring force
a) Magnetic force
b) Auxiliary release
≤ 1000 N acc. to GS-ET-19
-30 °C ... +60 °C
2 NC, 2 NO
4 slow make and break contact elements
1 x 106 switching cycles
3 x M5
10 Screws M3,5; 2 non-fused earthed conductor M4
0,5 - 2,5 mm²
0,5 - 1,5 mm²
2 x M20x1,5
≈ 0,84 kg
Operator definable
IP67 acc. to IEC/EN 60529
Actuation
4 different actuating directions achievable by rotating the actuating head.
Turning the actuator head (4 x 90 °) only when the actuator is plugged in.
Standards
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1
VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1
GS-ET-19
EU Conformity
Approvals
BG
CSA B300, R300 (same polarity)
UL
Notes
The degree of protection (IP code) specified applies solely to a property closed cover and the use of an equivalent
cable gland with adequate cable.
The switch may not be used as a mechanical stop.
When power is removed from the electromagnet (solenoid) the safety guard will be in locked position.
Remove hexagonal screw plug and push internal resin plunger in order to activate auxiliary release function.
Pre-travel actuator (compensation of shock and vibrations) approx. 9 mm.
This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims
for defects on account of possible variations of the actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications
subject to change without notice!
Date of issue: 11.01.2007 / Page 2 of 2
Document : 6017119020_en / Last update: 2 / 2010-07
Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica / www.bernstein-ag.de
Vorlage : 0850174285 Orig. 2