AC 输出

DIN Rail Mount
Datasheet
DR22 Series
AC Output DIN Rail Mount SSRs
• Output ratings up to 35 Amps at 600 VAC
• Built-in overvoltage protection
• Relay or Contactor configuration
• Integral heat sink eliminates the need for complex thermal calculations
• DBC substrate for superior thermal performance
• "Elevator" screw option to allow the use of ring or lug type terminals
• IP20 touch-safe housing
• AC or DC control
• C-UL-US and TUV approved
PRODUCT SELECTION
Control Voltage
90-280 VAC/VDC
4-32 VDC
20A
30A
35A
DR2260A20x
DR2260D20x
DR2260A30x
DR2260D30x
DR2260A35x
DR2260D35x
AVAILABLE OPTIONS
Series
DR22
Operating Voltage
60: 48-600 VAC
60
A
Rated Load Current
20: 20 Amps
30: 30 Amps
35: 35 Amps [High I2t]
U
V
20
Control Voltage (1)
A: 90-280 VAC/VDC
D: 4-32 VDC
Switching Type
Blank: Zero Voltage Turn-On
R: Instantaneous Turn-On
(Motor Rating Certified)
R
J
Terminal Layout
Input Connector
U: Relay Configuration
Blank: Screw Terminal
V: Contactor Configuration J: Spring Terminal
(std. screw)
(V and W suffixes only)
W: Contactor Configuration
(elevator screw)
Required for valid part number
For options only and not required for valid part number
OUTPUT SPECIFICATIONS (2)
Description
Operating Voltage (47-440Hz) [VRMS]
Transient Overvoltage [Vpk] (3)
Maximum Off-State Leakage Current @ Rated Voltage [mARMS]
Minimum Off-State dV/dt @ Maximum Rated Voltage [V/μsec]
Load Current, General Use UL508/LC A IEC62314 @ 40°C [ARMS]
Load Current, Motor Starting UL508 FLA/LC B IEC62314 @ 40°C [ARMS]
Minimum Load Current [mARMS]
Maximum 1 Cycle Surge Current (50/60Hz) [Apk]
Maximum On-State Voltage Drop @ Rated Current [Vpk]
Maximum 1/2 Cycle I² t for Fusing (50/60Hz) [A² sec]
Minimum Power Factor (at Maximum Load) (4)
Motor Rating UL 508/IEC62314 [HP (kW)]: 120 VAC
Motor Rating UL 508/IEC62314 [HP (kW)]: 240 VAC
Motor Rating UL 508/IEC62314 [HP (kW)]: 480 VAC
20A
30A
35A
48-600
1200
1
500
20
8.5/4.8
100
286/300
1.35
409/375
0.5
0.5 (0.37)
1.5 (1.1)
3 (2.24)
48-600
1200
1
500
30
14/7.6
100
716/750
1.35
2563/2343
0.5
1 (0.74)
3 (2.2)
5 (3.7)
48-600
1200
1
500
35
26/14
150
1290/1350
1.3
8320/7593
0.5
2 (1.5)
5 (3.73)
10 (7.4)
INPUT SPECIFICATIONS (2)
Description
DR2260Dxxx
DR2260Axxx
Control Voltage Range
Maximum Reverse Voltage
Minimum Turn-On Voltage
Must Turn-Off Voltage
Minimum Input Current (for on-state)
Maximum Input Current
Nominal Input Impedance
Maximum Turn-On Time [msec]
Maximum Turn-Off Time [msec]
4-32 VDC (5)
-32 VDC
4 VDC
1 VDC
10 mA
15 mA
Current Limited
1/2 Cycle (7)
1/2 Cycle
90-280 VAC/VDC (6)
90 VAC/VDC
5 VAC/VDC
6 mA
10 mA
Current Limited
20
30
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
DIN Rail Mount
Datasheet
GENERAL SPECIFICATIONS (2)
Description
Parameters
Dielectric Strength, Input to Output (50/60Hz)
Dielectric Strength, Input/Output to Case (50/60Hz)
Minimum Insulation Resistance (@ 500 VDC)
Maximum Capacitance, Input/Output
Ambient Operating Temperature Range (8)
Ambient Storage Temperature Range
Short Circuit Current Rating (9)
Weight (typical)
Housing Material
Heat Sink Material
Din Rail Clip Material
Hardware Finish
Input Terminal Screw Torque Range (in-lb/Nm)
Load Terminal Screw Torque Range (in-lb/Nm)
Humidity
LED Input Status Indicator
4000 VRMS
4000 VRMS
109 Ohms
8 pF
-40 to 80 °C
-40 to 100 °C
100kA
Option “U” 10.5 oz (298 g), Option “V”,“W” 10.6 oz (301 g)
UL94 V-0
Aluminum
Zink Plated Steel
Nickel Plating
Option “U” 13-15/1.5-1.7, Option “V”,“W” 5/0.5 (10)
Option “U” 13-15/1.5-1.7, Option “V”,“W” 18-20/2-2.2
95% non-condensing
Green
INPUT CURRENT INFORMATION
90-280 VAC/VDC Input
7
12
6
Input Current (mA)
Input Current (mA)
4-32 VDC Input
14
10
8
6
4
2
0
5
4
3
2
1
0
5
10
15
20
25
30
35
0
0
40
80
120
160
200
240
280
Input Voltage (VAC/VDC)
Input Voltage (VDC)
SURGE CURRENT INFORMATION
DR2260x30x
Surge Current (Amp) AC Peak
Surge Current (Amp) AC Peak
DR2260x20x
300
250
200
150
100
50
0
0.01
0.1
1
Surge Current (Amp) AC Peak
DR2260x35x
1200
1000
800
Single Pulse (11)
600
400
200
0.1
500
400
300
200
100
0
0.1
1
Surge Duration (sec)
1400
0.01
600
0.01
10
Surge Duration (sec)
0
700
1
10
Surge Duration (sec)
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
10
DIN Rail Mount
Datasheet
THERMAL DERATE INFORMATION (8)
DR2260x20x
Single unit (12)
DR2260x30x
Single unit (12)
Multiple units
15
10
5
0
20
30
40
50
60
Ambient Temperature (ºC)
70
30
35
25
30
20
15
10
5
0
80
Single unit (12)
Load Current (Amps)
Load Current (Amps)
Load Current (Amps)
20
DR2260x35x
Multiple units
20
30
40
50
60
Ambient Temperature (ºC)
70
EQUIVALENT CIRCUIT BLOCK DIAGRAMS/WIRING DIAGRAM
DC Control
+3/A1
OUTPUT
DC V
-
1/L1
INPUT
+
Trigger
Circuit
2/T1
-4/A2
Current
Limiter
Load
A
V AC
B
Load
Load can be wired in position A or B
AC/DC Control
Current
Limiter
+3/A1
AC/DC
Converter
OUTPUT
V
INPUT
-/
Load
A
+/
AC/DC
1/L1
Trigger
Circuit
-4/A2
2/T1
V AC
B
Load
Load can be wired in position A or B
Recommended Wire Sizes
Terminal
Configuration
Output (13)
Relay “U” suffix
Input
Relay “U” suffix
Output
Contactor
“V” &“W”
suffixes
Wire Size
(Solid / Stranded)
Wire Pull-Out
Strength (lb)[N]
2 x 18 AWG (1 mm2) Stranded
20 [88]
2 x 10 AWG (6 mm2) Stranded
60 [266]
2 x 18 AWG (1 mm2) Stranded
20 [88]
2 x 12 AWG (4 mm2) Stranded
40 [177]
2 x 20 AWG (0.75 mm2) [minimum]
25 [111]
2 x 10 AWG (6 mm2)
80 [355]
2 x 8 AWG (10 mm2) [maximum]
90 [400]
30 AWG (0.05 mm ) [minimum]
Input Screw
12 AWG (3.3 mm2) [maximum]
Contactor
“V” &“W”
26 AWG (0.13 mm2) [minimum]
suffixes Spring
12 AWG (3.3 mm2) [maximum]
2
4.5 [20]
30 [133]
5 [22]
5 [22]
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
80
Multiple units
25
20
15
10
5
0
20
30
40
50
60
Ambient Temperature (ºC)
70
80
DIN Rail Mount
Datasheet
MECHANICAL SPECIFICATIONS
Tolerances: ±0.02 in / 0.5 mm
All dimensions are in: inches [millimeters]
Contactor Configuration
1.87
[47.5]
Input Connector
1/L1
2.85
[72.3]
+3/A1
1.88
[47.8]
-4/A2
3.62
[91.9]
3.54
[90]
Screw
Terminal
Spring
Terminal
2/T1
1.19
[30.2]
0.89
[22.5]
4.59
[116.5]
Protective Earth Connection
Relay Configuration
0.39
[9.9]
+3/A1
INPUT
-4/A2
3.00
[76.2]
3.67
[93.2]
1.88
[47.8]
1/L1
OUTPUT
3.54
[90]
Protective Earth (PE) screw type recommended is
10-32 UNC standard not provided with SSR. Through
the use of a DIN rail ground (protective conductor)
terminal block, the DIN rail itself can be used as the
grounding bus bar. In this case, the zinc plated steel
material used for the DIN rail clip of DR22 models,
permits a secure path to ground and avoid the need of
a further PE connection.
2/T1
1.19
[30.2]
0.89
[22.5]
10-32
Thread
4.59
[116.5]
Elevator Screw (Suffix ‘W’)
TABLE 1. Compatible Terminals
W D
Terminals
W D
Fork Lug
Ring Lug
Width [W] in (mm)
0.45 (11.4)
0.45 (11.4)
Stud Size Dia [D] (in)
#8 (0.168)
#8 (0.168)
Crydom Part No.
Wire Size AWG
Do not forget to visit us at: www.crydom.com
Copper Lug
Copper Lug
TRM0
TRM6
6-0
14-6
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
The Elevator Screw option allows the screw and
clamp to be raised out of the mating threads
completely. This provides for the insertion and
use of a ring or lug type wire terminal. Refer to
TABLE 1 for Compatible Terminals.
DIN Rail Mount
Datasheet
ACCESSORIES
Recommended Accessories
New Accessories!
Connectors
Part number: CP201, CP202
Connectors
ID Marker
Lug Terminal
CP201
CNLB
TRM0
CP202
CNLN
TRM6
Pluggable input connectors, 2 position, with screw terminals (CP201) or
spring type terminals (CP202). Compatible with Contactor Configuration
NOVA22 SSRs.
Lug Terminal
CNL2
Part number: TRM0
Copper wire lug for AWG 6 (13.3 mm²) to AWG 0 (53.5 mm²) wire size. For
use with "Elevator" screw option ("W" suffix) NOVA22 SSRs.
AGENCY APPROVALS, CONFORMANCES AND EMC
(14)
E116949
E116949
Certification in accordance with:
United States Standard for Industrial Control Equipment - UL 508 and
Canadian Standard Association for Industrial Control Equipment – C22.2 No. 14.
TUV Certified in accordance to EN62314
Vibration Resistance:
IEC 60068-2-6: Amplitude Range 10-500 Hz, Displacement 0.75mm
Shock Resistance:
IEC 60068-2-27: Peak Acceleration 50g, Duration11ms.
Electromagnetic Compatibility
Generic
Standard
IEC 61000-6-2
Immunity for
Industrial
Environments
Inmunity Tests
Test Specification
Level
Performance
Electrostatic Discharge
8kV air discharge
Criterion A
IEC 61000-4-2
6kV contact discharge
Criterion A
Fast transients (burst)
Output
IEC 61000-4-4
Input
Surge
IEC 61000-4-5
Output
2kV, 5kHz, 100kHz Criterion B
1kV, 5kHz, 100kHz Criterion B
1kV Line to Line
Criterion B
2kV Line to Earth
Criterion B
AC Input 1kV Line to Line
Criterion A
Option
Criterion A
2kV Line to Earth
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
DIN Rail Mount
Datasheet
GENERAL NOTES
(1) Control voltage 18-52 VAC/VDC is available upon request.
(2) All parameters at 25°C unless otherwise specified.
(3) Output will self trigger between 900-1200 Vpk, not suitable for capacitive loads.
(4) High inductive loads requires nominal control voltage; AC input models only.
(5) Increase minimum voltage by 1 V for operations from -20 to -40°C.
(6) For ambient temperatures above 40°C the maximum control voltage must not exceed 250 VAC/VDC.
(7) Turn-on time for Instantaneous turn-on versions is 0.1 msec.
(8) AC input models operating range is -20 to 60 °C.
(9) When protected with the appropriate class and rated fuse. For detailed info please contact Crydom Technical Support.
(10) Input torque only for contactor (V,W) with screw terminals Connector.
(11) For single surge pulse Tc=25°C; Tj=125°C. For AC Output SSRs, AC RMS value of surge current equals the peak value divided by √2 (1.414).
(12) Minimum spacing to obtain max. current is 22.5mm between adjacent units.
(13) For 35 Amp Relay (”U”) layout models, use Pin Terminals (L 0.410 in x Ø 0.102 in) to install 8 AWG wire.
(14) Applicable to Relay (”U”) option.
Rev. 060216
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
DIN Rail Mount
Datasheet
DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / 危险
HAZARD OF
ELECTRIC
SHOCK,
EXPLOSION,
OR ARC FLASH.
• Disconnect all
power before
installing or
working with
this equipment.
• Verify all
connections
and replace all
covers before
turning on
power.
Failure to follow
these
instructions will
result in death
or serious injury.
RIESGO DE
DESCARGA
ELECTRICA O
EXPLOSION.
• Desconectar
todos los
suministros de
energia a este
equipo antes
de trabajar
con este equipo.
• Verificar todas
las conexiones
y colocar todas
las tapas antes
de energizer
el equipo.
El
incumplimiento
de estas
instrucciones
puede provocar
la muerte o
lesiones serias.
RISQUE DE
DESCHARGE
ELECTRIQUE
OU EXPLOSION
• Eteindre
toutes les
sources
d'énergie de
cet appareil
avant de
travailler
dessus de cet
appareil
• Vérifier tous
connections, et
remettre tous
couverts en
olace avant de
mettre sous
De non-suivi de
ces instructions
provoquera la
mort ou des
lésions sérieuses
sérieuses.
GEFAHR EINES
ELEKTRISCHE
N SCHLAGES
ODER EINER
EXPLOSION.
• Stellen Sie
jeglichen
Strom ab, der
dieses Gerät
versorgt, bevor
Sie an dem
Gerät Arbeiten
durchführen
• Vor dem
Drehen auf
Energie alle
Anschlüsse
überprüfen
und alle
Abdeckungen
ersetzen.
Unterlassung
dieser
Anweisungen
können zum
Tode oder zu
schweren
Verletzungen
führen.
RISCHIO DI
SCOSSA
ELETTRICA O
DELL’ESPLOSIONE.
• Spenga tutta
l'alimentazione
che fornisce
questa
apparecchiatura
prima di lavorare
a questa
apparecchiatura
存在电击、
爆炸或电弧
闪烁危险
•
在操作此设
备之前请先
关闭电源。
若不遵守这些说明,
可能会导致严重的
人身伤害甚至死亡。
• Verificare tutti
i collegamenti
e sostituire
tutte le coperture
prima
dell’accensione
L'omissione di
queste istruzioni
provocherà la
morte o
lesioni serie
WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / 警告
RISK OF MATERIAL DAMAGE AND HOT
ENCLOSURE
RISQUE DE DOMMAGE MATERIEL ET DE
SURCHAUFFE DU BOITIER
GEFAHR VON MATERIALSCHÄDEN UND
GEHÄUSEERHITZUNG
• The product's side panels may be hot, allow
the product to cool before touching.
• Follow proper mounting instructions including
torque values.
• Do not allow liquids or foreign objects to enter
this product.
• Les panneaux latéraux du produit peuvent être
chauds. Laisser le produit refroidir avant de le
toucher.
• Respecter les consignes de montage, et
notamment les couples de serrage.
• Ne pas laisser pénétrer de liquide ni de corps
étrangers à l'intérieur du produit.
• Die Seitenwände können heiß sein. Lassen Sie
das Produkt abkühlen, bevor Sie es berühren.
• Beachten Sie die Montageanweisungen,
• Führen Sie keine Flüssigkeiten oder
Fremdkörper in das Produkt ein.
Le non-respect de cette directive peut entraîner,
Failure to follow these instructions can result in des lésions corporelles graves ou des
serious injury, or equipment damage.
dommages matériels.
Die Nichtbeachtung dieser Anweisung kann
Körperverletzung oder Materialschäden
zur Folge haben.
RIESGO DE DAÑOS MATERIALES Y DE
SOBRECALENTAMIENTO DE LA UNIDAD
RISCHIO DI DANNI MATERIALI E D'INVOLUCRO
CALDO
材料损坏和高温外壳的危险性
• Los paneles laterales del producto pueden
estar calientes. Esperar que el producto se
enfríe antes de tocarlo.
• Respetar las instrucciones de montaje, y en
particular los pares de apretado.
• No dejar que penetren líquidos o cuerpos
extraños en el producto.
• I pannelli laterali dell'apparecchio possono
scottare; lasciar quindi raffreddare il prodotto
prima di toccarlo.
• Seguire le istruzioni di montaggio corrette.
• Non far entrare liquidi o oggetti estranei in questo
apparecchio.
Si no se respetan estas precauciones pueden
producirse graves lesiones, daños materiales.
La mancata osservanza di questa precauzione può
causare gravi rischi per l'incolumità personale o
danni alle apparecchiature.
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
• 产品的一侧面板可能很热,在其冷却前请
不要触碰。
• 遵照正确的安装说明,包括扭矩值。
• 请勿让液体及其他异物进入本产品。
如不能正确执行这些操作说明,
极有可能造成严重人体伤害或者设备的损坏。
DIN Rail Mount
Datasheet
ANNEX - ENVIROMENTAL INFORMATION
The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People’s Republic of China
Electronic Industry Standard SJ/T11364 – 2006, Marking for Control of Pollution Caused by Electronic Information Products.
Part
Name
Toxic or hazardous Substance and Elements
Lead
(Pb)
Mercury
(Hg)
Cadmium
(Cd)
Hexavalent
Chromium
(Cr (VI))
Polybrominated
biphenyls
(PBB)
Polybrominated
diphenyl ethers
(PBDE)
Semiconductor die
Solder
附件 - 环保信息
此附件所标示的包括电子信息产品污染图标的环保信息符合中华人民共和国电子行业标准 SJ/T11364 - 2006,
电子信息产品污染控制标识要求。
部件
名称
铅
汞
镉
有毒有害物质或元素
六价铬
多溴联苯
(Pb)
(Hg)
(Cd)
(Cr (VI))
半导体芯片
焊接点
50
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
(PBB)
多溴二苯醚
(PBDE)