Technical Data: RT2Y

RT2Y
Compact temperature switch intrinsic safety
Main Features
„„
Excellent repeatability
„„
Fix dead band for control and alarm
„„
Resistant to accidental overtemperature
„„
Intrinsic safety Hazardous area 0, 1, 2
Applications
„„Power generation safety equipment
„„Water treatment
„„Valve and compressor control
Technical Data
Temperature range
-46 ... 0 °C to 160 ... 250 °C
Temperature
Process : Ambient : Storage : -46 ... +250 °C
-30 ... +70 °C (T5)
-30 ... +55 °C (T6)
-40 ... +70 °C
Electrical
connection
Via internal terminal block with cable gland for
Ø 5.5 to 8.5 mm
Electrical function
See ordering code details in page 5
Adjustment
Internal adjustment possible for set point
ATEX
Bulb
Stainless steel 1.4404 (316L) Ø 9.5 mm
Scale
Internal graduated scale
Weight
0.960 kg + transmission
Body
Zamak black painting
Housing
Plastic PA6, blue
Mounting
Wall mounting 2 x M5 screws
Type examination certificate
LCIE 03 ATEX 6160X
EN 60079-0: 2012 (internal conformity analysis)
EN 60079-11: 2012
Marking
0081
IM1
Ex ia I Ma
II 1 G
Ex ia IIC T6 or T5 Ga
Electrical data
Umax = 30 Vdc
Imax = 66 mA
Pmax = 0.5 W
Ground connection
Via internal terminal block
Ci = Negligible ; Li = Negligible
Repeatability
± 1% F.S. / constant temperature cycle
CE conformity
Low Voltage Directive LVD 2006/95/EC
ATEX Directive 94/9/EC
Protection rating
IP 66 (EN 60529)
Process connection
Stainless steel 1.4404 (316L)
Code SETP
Mounting on 2" pipe
Code 0407
Stainless steel tag plate and wire
Code 9941
Lead seal of the housing
Code 8990
2015-10-19
Customer specific set point adjustment
Design and specifications subject to change without notice
Options
www.baumer.com
Data sheet B31.04
Page 1 / 5
RT2Y
Compact temperature switch intrinsic safety
Principle
A vapour filled flexible sensing element actuates a microswitch by
means of a piston. The set point is adjusted by means of a compressible spring installed in opposition.
NC
NC
T°C
P
NC
C
C
C
NO
NO
Set point and reset point must be between 10% and 90% of the
selected scale.
NO
Standard factory adjustment
Setpoint at 50% of the scale on falling temperature
Customer specific factory adjustment (option SETP)
The following specifications have to be given with the order:
• Setpoint value
• Adjustment on falling or raising temperature
NC
C
NC
NC
C
C
NO
NO
NO
Adjustable ranges
Micro-switch dead band 1)
T°C max
Fixed dead band
Code
°C
°C
M
10%
90%
°C
°C
-46 ... 0
40
40
5
4
-20 ... 20
60
41
5
4
0 ... 45
80
42
3.5
3
40 ... 120
145
43
6
6
100 ... 180
190
44
7
5.5
20 ... 90
120
45
11
11
160 ... 250
290
46
6.5
5
70 ... 150
175
48
11
8
The value of the dead band is depending on the value of the set point.
This table contains the dead band values for set point adjustment at 10% and 90% of the selected scale. For other set points the dead band value can be calculated
by linear interpolation between the values at 10% and 90%.
2015-10-19
1)
Design and specifications subject to change without notice
Scale
www.baumer.com
Data sheet B31.04
Page 2 / 5
RT2Y
Compact temperature switch intrinsic safety
Micro switches characteristics
M
Switch code
Gold contact
6 Vdc
10 ... 50 mA
12 Vdc
10 ... 50 mA
24 Vdc
10 ... 50 mA
30 Vdc
10 ... 50 mA
48 Vdc
N/A
110 Vdc
N/A
220 Vdc
N/A
115 Vac
N/A
250 Vac
N/A
Dielectric rigidity between contacts and ground
2000 V
Electrical connections
Micro switch
NC
Blue
COM
Red
NO
Terminal block
White
Certified safety
barrier
Hazardous area
Zone 0, 1, 2
NO
C
Non hazardous
area
NO
or NC
NC
+
Rc 1
Yellow / green
Supply
–
Screen
For max. ambient temperature according to temperature classes T5 and T6 refer to technical data on page 1.
The installation must be made in an intrinsically safe circuit whose certified electrical safety parameters do not exceed any of the values Umax,
Imax and Pmax given in the electrical data on page 1.
2015-10-19
Design and specifications subject to change without notice
All necessary measures must be taken by the user, to avoid the calorific transfer from the fluid to the apparatus head increasing the head's
temperature to such that it reaches the self-ignition temperature of the gas in which it is used.
www.baumer.com
Data sheet B31.04
Page 3 / 5
RT2Y
Compact temperature switch intrinsic safety
Dimensions (mm)
Direct mount temperature switches
Temperature switches with capillary
97
73,5
S = Bulb length (temperature sensitive part)
A = Additional stem length (min. 25 mm)
98
P = Immersion length (P = S + A)
K = Capillary length (only TD1, TD2, TD3)
flats
27/ 2 plats
2 grooves 5,5
33
68
E = Extension between process connection and
housing only TRDE1 and TRDE2
33
E
For version TD1 there is no additional stem length
(A = 0). The sliding connection is mounted on the
capillary.
K ±2%
K ±2%
A
Ø8
P± 3
Ø8
Ø 2,6
P±3
S
100
A
Ø8
Ø 9,5
S
S
Ø 9,5
TRDE 1/2
TD1
TD2
Stainless steel sliding male connection (TD2/3, TRDE1/2)
Clamping
ring
Stainless steel sliding male connection (TD1)
Thread and sizes
A
Clamping nut
Process
connection
TD3
B
L
H
F
Thread and sizes
A
F
G 1/2
1/2 NPT
H
18
21
L
36
40
A
17/flat
17/flat
B
23/flat
23/flat
Clamping nut
B
Tightness
fittings
L
Process
connection
H
F
After tightening of the clamping
nut, the stem is fixed in the process
connection. Tight up to 40 bar.
F
G 1/2
1/2 NPT
H
18
21
L
43
46
A
27/flat
27/flat
B
27/flat
27/flat
Waterproof after tightening mounted
on the capillary.
TRDE1
TRDE2
Capillary
Code
40
41
42
43
44
45
46
48
n/a
S / mm
100
100
100
100
n/a
100
n/a
n/a
n/a
S / mm
100
100
100
100
100
100
100
100
TD1, TD2, TD3
K = 1...4 m
S / mm
100
100
100
100
100
100
100
100
TD1, TD2, TD3
K = 5...7 m
S / mm
100
150
150
100
100
150
100
100
TD1, TD2, TD3
K = 8...10 m
S / mm
100
200
200
100
100
200
100
100
Design and specifications subject to change without notice
Bulb length (S) according to the capillary length (K) and the temperature range (code)
2015-10-19
Versions with S = 150 mm or S = 200 mm are not feasible with P = 150 mm
www.baumer.com
Data sheet B31.04
Page 4 / 5
RT2Y
Compact temperature switch intrinsic safety
Ordering details RT2Y
RT2
Model
Compact temperature switch
RT 2
Approvals
ATEX intrinsic safety
Type of microswitch
1 SPDT gold contact change over switch
.
/
.
–
Y
M
.
40
41
42
43
44
45
46
48
(not for TRDE1)
(not for TRDE1)
(not for TRDE1)
Type of transmission
TD1
Stainless steel capillary without protection
TD2
Stainless steel capillary with stainless steel protection
TD3
Stainless steel capillary with stainless steel protection and PVC coating
TRDE1
Rigid transmission with E=65 mm for temperature measurement below 120 °C
TRDE2
Rigid transmission with E=120 mm for all temperature measurement
Capillary length (K)
Direct mounting
(for TRDE1 and TRDE2)
1 meter
2 meters
3 meters
4 meters
5 meters
6 meters
7 meters
8 meters
9 meters
10 meters
Immersion length (P)
Immersion length (P) = Bulb length (S) + additional stem length (A)
P = S + 25 mm (minimum additional stem length A = 25 mm, for S see table on page 4)
P = 150 mm
(not for TD1)
P = 250 mm
(not for TD1)
P = 400 mm
(not for TD1)
P = 600 mm
(not for TD1)
P = 1000 mm
(not for TD1)
Bulb diameter
Ø 9.5 mm
Process connection
Without
G1/2 male (standard)
1/2 NPT male
Options to be added behind the / (see example below)
.
1
2
3
C
D
0
1
2
3
4
5
6
7
8
9
A
0
3
4
5
6
D
C
0
3
6
/
Ordering example with options
RT2
–
Y
M
.
40
.
2
1
3
C
3
/
9941
www.baumer.com
2015-10-19
Compact temperature switch
ATEX intrinsic safety
1 SPDT gold contact change over switch
Temperature range -46 ... 0 °C
Transmission TD2
Capillary 1 meter
Immersion length 150 mm
Bulb Ø 9.5 mm
Process connection G1/2
Option: Stainless steel tag plate and wire
Design and specifications subject to change without notice
Temperature range (°C)
-46 ... 0
-20 ... 20
0 ... 45
40 ... 120
100 ... 180
20 ... 90
160 ... 250
70 ... 150
–
Data sheet B31.04
Page 5 / 5