(Y)TED hygienic pressure switch Main Features -1 … 0 bar up to 0 … 25 bar Robust stainless steel housing for severe industrial environments Intrinsically safe version (LCIE 03 ATEX 6300 X) Two threshold outputs (PNP transistors or galvanic isolation) Applications Food & Beverage Main characteristics Measuring ranges -1 ... 0 bar up to 0 ... 25 bar Long term stability ≤ ± 0.2% FS/Year Accuracy ≤ ± 0.5% FS Measuring principle Thick film on ceramic -1 ... 0 bar up to 0 ... 25 bar Type of pressure Relative / Absolute Accuracy ≤ ± 0.5% FS Thermal drift ≤ ± 0.15% FS/10 K Long term stability ≤ ± 0.2% FS/Year Threshold outputs TED6 Galvanically isolated pressure switch with two thresholds as static relays, switching capacity of 400 mA at 60 VDC or 40 VAC Pressure switch with two thresholds as PNP transistors, switching capacity of 400 mA at 24 VDC TED7 Pressure switch with two thresholds as PNP transistors,switching capacity of 400 mA at 24 VDC TEDM Galvanically isolated pressure switch with Modbus communication with two thresholds as static relays, switching capacity of 400 mA at 60 VDC or 40 VAC Intrinsically safe pressure switch with two thresholds as PNP transistors, switching capacity of 40 mA at 28 VDC 2% to 98% of the measurement range YTED Threshold adjustment range Typical response time Repeatability of switching points www.baumer.com RΩ = (Usupply-10 V) / 0,02 A Current ouput (3 wires) RΩ ≤ 400 Ω Voltage output RΩ > 5 kΩ Insulation resistance >100 MΩ at 500 VDC Environment Process connections See page 4 TED5 Load impedance Current ouput (2 wires) Temperature Storage Medium Ambient -40 ... +85°C -25 ... +100°C -25 ... +85°C Protection rating IP67 (EN 60529) Vibration IEC60068-2-6 1.5 mm p-p (10 – 55 Hz), 20 g (55 Hz – 2 KHz) Shock IEC60068-2-27 25 falls from 1 m on concrete ground Design and specifications subject to change without notice (includes linearity, hysteresis, repeatability, error of span and zero point according limit point adjustment) 4 … 20 mA (2 wires) / 10 … 32 VDC 4 … 20 mA (3 wires) / 10 … 28 VDC 4 … 20 mA (2 wires - ATEX version) / 10 … 28 VDC 0...10 V / 10 ... 32 VDC Modbus / 10 ... 32 VDC Technical specifications Measuring ranges Output signal / Power supply Material Process connection SS 1.4404 AISI 316L Housing SS 1.4301 AISI 304 Diaphragm SS 1.4404 AISI 316L Sealing NBR ≤ 20 ms 2013-11-21 (includes linearity, hysteresis, repeatability, error of span and zero point according limit point adjustment) Electrical specification ≤ ± 0.2% FS Data sheet A31.08 Page 1 / 5 (Y)TED hygienic pressure switch Version with galvanically isolated digital thresholds – TED5 and TEDM The current supply to the pressure switch is electrically isolated from the threshold outputs and the threshold outputs are isolated from each other.400 mA at 60 VDC or 40 VAC. It is possible to have a separate power supply between the TEDM (≤ 32 VDC) and the threshold contacts (≤ 60 VDC or ≤ 40 VAC). Configuration The three keys on the front panel are used to configure the following operating parameters: ● Switching point value for each threshold ● Switching hysteresis value for each threshold ● Active status for each threshold (NO or NC) ● Time delay of each threshold from 0 to 25 s in 0.1 s steps ● Auto-zero function ● Self test and parameter protection by a 4 digit code Additional parameter for the TEDM: ● Modbus slave address of the pressure switch ● Parity selection Maximum and minimum value consultation When the pressure switch is in the measurement mode it is possible to display or initialise the maximum and minimum pressure values saved at any time. Modbus communication The TEDM has a RS485 serial port and uses the Modbus RTU communication protocol. The Modbus protocol is a two-way exchange protocol based on a hierarchical data base structure between a master and multiple slave stations. It enables the user to read the pressure and the status of each threshold (open or closed). Exchange between the master and one slave: The master sends an order and waits for a reply. Exchange between the master and all slave stations: The master broadcasts a message to all the slaves in the network and they perform the order in the message without sending a reply. Two slave stations cannot talk together. Parameter consultation Parameters for each threshold, Modbus address (TEDM) and parity (TEDM) can be viewed whithout access code. Threshold state: Increasing 2013-11-21 Design and specifications subject to change without notice Threshold state: Decreasing www.baumer.com Data sheet A31.08 Page 2 / 5 (Y)TED hygienic pressure switch Installations YTED ATEX I M1 Ex ia I Ma Non hazardous area Hazardous area (0,1, 2) Umax = 28 Vcc Imax = 120 mA P = 0.8 W YTED YTED II 1 G Ex ia IIC T6 or T5 Ga Ci = 13,2 nF Imax = 120 mA Li = 0 Barrier data Ui ≤ 28 V Ii ≤ 120 mA Pi ≤ 800 mW Capacity Ci ≤ 13.2 nF Inductivity Li ≤ 0 μH Ambient temperature Ta In area 0, the combination of the pressure switch and the safety barrier must be covered by a calculation checked by an approved body. For the application in Ex zone you have to respect the conditions mentioned in the ATEX Type Examination Certificate (LCIE 03 ATEX 6300 X). You find the certificates and manuals under http://www.baumer.com/ Ta = +40°C Ta = +70°C G: T6 G: T6 (G = Gas) Approvals CE conformity EMC directive 2004/108/CE in accordance with EN 61000-6-2, EN 61000-6-3, EN 61326-1 (Tab. 2) Pressure directive 97/23/CE Measuring ranges and overpressure safety Pressure in bar Pressure range -1 ... 0 -1 ... 0.6 -1 ... 1.5 -1 ... 3 -1 ... 5 -1 ... 9 -1 ... 15 -1 ... 24 Over pressure 3 3 4 8 12 20 32 50 80 Burst pressure 6 6 7 12 18 30 48 75 120 -1.000 / 0 -1.000 / 0.600 -1.000 / 1.500 -1.000 / 3.000 -1.000 / 5.000 -1.000 / 9.000 -1.00 / 15.00 -1.00 / 24.00 -1.00 / 39.00 0 ... 4 0 ... 6 0 ... 10 0 ... 16 0 ... 25 50 Display at measurement range -1 ... 39 Pressure in bar Pressure range 0 ... 1 0 ... 1.6 0 ... 2.5 Over pressure 3 3 4 8 12 20 32 Burst pressure 7 7 7 12 18 30 48 75 0/1.000 0/1.600 0/2.500 0/4.000 0/6.000 0/10.000 0/16.000 0/25.000 2013-11-21 Design and specifications subject to change without notice Display at measurement range www.baumer.com Data sheet A31.08 Page 3 / 5 (Y)TED hygienic pressure switch Dimensions (mm) Ø 45 13 connector M12 bar R S2 103 S1 39 F DN ØD Bar DN25 Ø 50.5 2.5 ≤ P ≤ 25 DN38 Ø 50.5 0.4 ≤ P ≤ 25 DN51 Ø 64 0.25 ≤ P ≤ 25 Pin assignment TED7 - Voltage output TED7 1 TED6/YTED - Current output (4-20 mA, 2 wires) TED6 +Power supply (+) A (+) A 1 + Power supply 2 Threshold 2 2 Threshold 2 4-20 mA 4 Threshold 1 3 Measure U 3 4-20 mA measure 4 Threshold 1 5 RL - Power supply (-) A (-) A 5 Ground TED5 1 + Power supply 7 + Measure (+) A TEDM 7 Threshold 1 2 DAT B 1 DAT A 3 RL 5 4 6 Threshold 2 5 2 - Supply / - Measure (-) A T 6 8 Threshold 1 Threshold 2 - Power supply 2013-11-21 8 Ground + Power supply 4-20 mA 3 4 TEDM - Modbus output RS485 Design and specifications subject to change without notice TED5 - Current output (4-20 mA, 3 wires) T www.baumer.com Data sheet A31.08 Page 4 / 5 (Y)TED hygienic pressure switch Codification (Y)TED Model 2 galv. Separated switching points, 4...20mA (3 wires) 2 switching points, 4...20mA (2 wires) 2 switching points, 0...10 V 2 switching points,Modbus RS485 2 switching points, 4…20 mA, ATEX Ex ia intrinsic safety Process connection CLAMP ISO DN 25 CLAMP ISO DN 38 CLAMP ISO DN 51 P ≥ 2.5 bar TED5 TED6 TED7 TEDM YTED xx . x type type type type type type type type type relative relative relative relative relative relative relative relative relative xxx . x / xxxx . 3 pressure pressure pressure pressure pressure pressure pressure pressure pressure . – 15 18 11 Sealing NBR Pressure range and unit in bar Only -1...0 Only -1...0.6 Only -1...1.5 Only -1...3 Only -1...5 Only -1...9 Only -1...15 Only -1...24 Only -1...39 0...1 0...1.6 0...2.5 0...4 0...6 0...10 0...16 0...25 – . B59 B72 B74 B76 B77 B79 B81 B82 B1L B15 B16 B18 B19 B20 B22 B24 B26 Kind of pressure Relative Absolute . R A Options Drinking water application Process connection electropolished Ra ≤ 0.4 Capacitive cell (except YTED) M12, 5 pins with shielded cable, length 2 m M12, 5 pins with shielded cable, length 5 m M12, 5 pins with shielded cable, length 10 m M12, 8 pins with shielded cable, length 2 m M12, 8 pins with shielded cable, length 5 m M12, 8 pins with shielded cable, length 10 m / 2013-11-21 Design and specifications subject to change without notice 0619 0593 0591 0604 0605 0606 0607 0608 0609 www.baumer.com Data sheet A31.08 Page 5 / 5