Temperature Sensor TE2

Temperature Sensor TE2
Compact RTD temperature sensors
Main features
„„
Compact and light weight
„„
Available with 4...20 mA transmitter or Pt100 output
„„
Available with hygienic as well as industrial process connections
„„
Programmable by FlexProgrammer 9701
Applications
„„Food & Beverage
„„Laboratory & Medical
„„Oil & Gas / Chemical
„„Water & Waste water
Technical specification
„„Energy
„„Transportation & Logistics
Environment
Housing
Compact Ø 18mm
Stainless steel AISI 304 (1.4301)
Ambient temperature
El. connection
M12 or DIN 43650 plug
Process temperature
-50...250°C
Output
Pt100 or 4...20mA
Protection class
M12 : IP67 / DIN 43650 : IP65
Sensor tube material
Stainless steel AISI 316L (1.4404)
PEEK
Humidity
<100% RH, condensing
Vibrations
GL, test 2
Sensor diameter outside
Ø 6mm
Sensor length
< 3 000 mm
Standard response tip
Fast response tip
Ø 6, Ø 4 or Ø 3
-40...125°C
-40...85°C
Temperature curve
°C
300
250
In water
In water
In water
In water
3.0 sec.
2.5 sec.
1.3 sec.
<1.0 sec.
Sensor element, Pt100 DIN/EN/IEC 60751
± (0.3 + 0.005 × t) °C
± 1/3 x (0.3 + 0.005 × t) °C
± 1/6 x (0.3 + 0.005 × t) °C
± (0.15 + 0.002 × t) °C
Single element
Double element
1 × Pt100
2 × Pt100
Connection
4-wire, 2 × 2 wire
150
100
85°C
85°C
50
0
0
20
40
60
80
100 °C
with cooling neck
without cooling neck
EN/2013-11-14
Pt100 DIN class B
Pt100 1/3 DIN class B
Pt100 1/6 DIN class B
Pt100 DIN class A
200
Design and specifications subject to change without notice
Time constant τ0.5
Sensor tip Ø 6mm
Sensor tip Ø 4mm
Sensor tip Ø 3mm
Conical sensor
Pt100 output
w. transmitter
www.baumer.com
Data sheet B12.05 TE2
Page 1 / 4
Temperature Sensor TE2
Compact RTD temperature sensors
Dimensions (mm) and constructions details
Plug M12
with transmit.
Plug
DIN 43650-A
with transmit.
Plug
DIN 43650-A
70
42
50
26
Plug M12
50
Ø 18
46
Ø18
AF 22
M12x1.5
AF 22
20
24.5
27
G1/2A
AF 17
8
AF 22
Cooling neck
G1/4
DIN 3852-E
G1/2A
L
Ø6
Ø6
L
L
Ø6
L
Ø6
L
Ø6
G½A, ISO 228/1
Code 3
M12x1.5 cone
Code 6
Standard
Tip
Triclamp®
Code A
Fast
response tip
Ø6
Conical sensorCode 7
3A DN 38
Code B
EN/2013-11-14
ISO 2852 DN 38
Code 9
Design and specifications subject to change without notice
Ø3
PEEK
Ø3
L
L
L
L20/L25
Ø6
Ø6
M12x1.5
6
58/63
32
22
21
AF17
G¼A DIN 3852-E
Code 8
20
G½A Hygienic
Code 4
Without thread
Code 1
32
M12x1.5
Code 5
Ø3 or Ø4 mm
Ø6
www.baumer.com
Ø6
Data sheet B12.05 TE2
Page 2 / 4
Temperature Sensor TE2
Compact RTD temperature sensors
Electrical connections
Plug DIN 43650-A
M12 Plug
Transmitter
Output
Accuracy
< 0.25°C (@ ≤ 100°C)
Signal span
4...20 mA, 2-wire
Sample time
< 0.7 sec.
Accuracy
< 0.1% of signal span
Pt100 standard
IEC/DIN/EN 60 751-2
Supply range
8...35 VDC
RTD measuring current
0.3 mA, continuously
Ripple immunity
3 Vms
Error detection delay
< 10 sec.
Load equation
RL ≤ (VDC -8)/23 [kOhm]
Measuring unit
°C or °F
Up/Down scaling limits
23 mA/3.5 mA
Minimum span
25°C
Damping
0...30 sec.
Protection
± 35 VDC
Protection
Reserved polarity protection
Surpression
50 and 60 Hz
Resolution
12 bit
Resolution
14 bit
Effect of variations in supply voltage
Repeatability
< 0.1°C
Output current
Ripple immunity
IEC 770 6.2.4.2
Offset adjustment
Max. ± 10°C
Isolation, sensor to case
50 VAC (test 500V)
Other data
Temperature drift
20 sec.
Environmental conditions
Operating temperature
-40...85°C
Storage temperature
-55...90°C
Long-term test
IEC 770 6.3.2
EMC data
Generic standards
EN 61000-6-3, EN 61000-6-2
Product standard
EN 61326
Namur
NE21
EN/2013-11-14
Power-on time
Typ. 0.003% per °C
Max. 0.01% per °C
0.01% per volt
Design and specifications subject to change without notice
Input
www.baumer.com
Data sheet B12.05 TE2
Page 3 / 4
Temperature Sensor TE2
Compact RTD temperature sensors
Ordering details TE2
TE2
Model
– x .
x .
x
x
x
x .
xxxx
.
x
TE2
Compact temperature sensor
Sensor tip
Not specified
Standard
Fast
Fast
For connection code 6 & 7
Normal response
Fast response
Ø4 mm
Fast response
Ø3 mm
Sensor lenght 35...300 mm
Sensor lenght 35...300 mm
G½
G½ hygienic
M12 x 1.5 hygienic
M12 x 1.5 hygienic
Conical sensor
G¼″
(1″, 1½″)
(DN15/DN20)
Hygienic connection
PN40
PN100
PN40
PN40
PEEK cone Ø3 x 5 mm tip PN40
Ø3 x 20 mm or 25 mm sensor tip PN40
PN100
PN40
PN40
PN40
Process connection
Tube without connection
Nipple, male
Nipple, male
Nipple, male
Nipple, male
G⅛″ union nut
Nipple, male
DN25/DN38 clamp
Triclamp® ½″, ¾″
3A/DN38
ISO 228/1
ISO 228/1
ISO 228/1
ISO 228/1
DIN 3852-E
ISO 2852
Sensor element
1 x Pt100 CI. B
2 x Pt100 CI. B
1 x Pt100 CI. 1/3 B
2 x Pt100 CI. 1/3 B
1 x Pt100 CI. 1/6 B
1 x Pt100 CI. A
2 x Pt100 CI. B
Cooling neck
None
Cooling neck
Electrical connection
M12 plug, 4 pole
M12 plug, 4 pole
DIN 43650-A
DIN 43650-A
0
1
2
3
.
1
3
4
5
6
7
8
9
A
B
.
1
2
3
4
5
7
8
For 6 mm standard tip only
For 6 mm standard tip only
For 6 mm standard tip only
0
4
See table page 1
with 4...20 mA transmitteur
1 x Pt100 only
with 4...20 mA transmitteur without u
1 x Pt100 only
1
2
4
5
Certificates
Not specified
0
Sensor tube length
5 mm for connection code 6
20 mm for connection code 7
25 mm for connection code 7
Length in mm (e.g. 60 mm = 0060)
.
0005
0020
0025
xxxx
Configuration
No configuration
Configuration of range
.
EN/2013-11-14
Design and specifications subject to change without notice
0
C
www.baumer.com
Data sheet B12.05 TE2