SDI0501710

celduc®
r
e
l
a
i
S/CON/SDI0501710/A/07/04/16
s
Page 1/11 GB
IGBT BASED
DC SOLID STATE RELAY
SDI0501710
 Latest IGBT technology generation.
 Ultra low drop out voltage at on-state (low power losses).
 Built-in protection against overvoltage and fasts transients bursts.
 Built-in protection against overload and shorts-circuits of the load.
 Built-in over-temperature protection.
Nominal Control voltage
 Pluggable control connector with spring terminals
Nominal. output voltage
72-96
&110VDC
750VDC
Nom. load current with
heatsink
Load voltage range
Load current range
12 to 940VDC
0 à 50A
(with heatsink)
Control input
voltage
72-96-110VDC
Fig. 1
50ADC
Supply voltage
range
Visualizations
Dimensions
(WxHxD)
Weight
72-96-110VDC
3 LEDs :
-SUPPLY (Green)
-STATUS (Orange)
-FAULT (Red)
157 x 68 x 83
(mm)
1050g
INTERNAL DIAGRAM
X4/10 +
+
Supply
X4/9 -
X11
+
Control
Input
Vclamp
X4/8 +
Driver
µC
X4/7 X4/6 +
Power
Output
+
X12
FAULT
X4/5 X4/4 +
STATUS
SUPPLY
Diagnostic
Output
-
Thermal
Detection
+
Status
Output
X4/3 X4/2
nc
X4/1
nc
Proud to serve you
Data given at Tambient=40°C and subject to modification without previous notice
®
celduc
r
e
l
a
i
s
celduc®
r
e
l
a
i
S/CON/SDI0501710/A/07/04/16
s
Page 2/11 GB
EXAMPLES OF WIRING DIAGRAM
SDI range
Fig. 2
SUPPLY INPUT
CHARACTERISTIC
LABEL
VALUE
Us
72/96/110Vdc
Marking
SUPLLY CIRCUIT
Nom. supply voltage
X4/1 & X4/2
Min. supply voltage
Us min
50.4Vdc
Max. supply voltage
Us max
137.5Vdc
Max. peak voltage
INFO.
Usp
154Vdc
Typ. operating current
Is
<40mA
Max. reverse current
-Is
<1µA
Overvoltage protection
Transient voltage suppressor
Internal Overcurrent and shortscircuits protection
Thermistor
Reverse polarity protection
YES
Under Voltage Lockout protection
UVLO
YES
Proud to serve you
Data given at Tambient=40°C and subject to modification without previous notice
@pulse<1s
®
celduc
r
e
l
a
i
s
celduc®
r
e
l
a
i
S/CON/SDI0501710/A/07/04/16
s
Page 3/11 GB
CONTROL INPUT
CHARACTERISTIC
LABEL
VALUE
INPUT CIRCUIT
Marking
Control voltage range
Fig. 3
X4/3 & X4/4
Uc
72/96/110Vdc
Current consumption
Ic
<5mA
Max. reverse current
-Ic
<1µA
Min. switch-on voltage
Uc_on_min
43.2V
Min. releasing voltage
Uc_off_min
4Vdc
Max. input voltage
Ucmax
137.5Vdc
Max. reverse voltage
-Ucmax
137.5Vdc
Re
Current limitation
Input impedance
INFO.
See fig. 3
CONTROL INPUT CHARACTERISTICS
Proud to serve you
Data given at Tambient=40°C and subject to modification without previous notice
®
celduc
r
e
l
a
i
s
celduc®
r
e
l
a
i
S/CON/SDI0501710/A/07/04/16
s
Page 4/11 GB
POWER OUTPUT
CHARACTERISTIC
Nom. power voltage
VALUE
Ue
750Vdc
INFO.
Min. power voltage
Uemin
12Vdc
Max permanent voltage
Umax1
940Vdc
Non-permanent voltage
Umax2
1000Vdc
@pulse<5min
Repetitive peak voltage
Umax3
1270V
@pulse<20ms
Max. nominal currents
Ice
50A
See fig. 4
Values with
heatsink
Min. nominal currents
Ice min
0.1A(*1)
Non-repetitive IGBT peak overload
current
Icepeak
300A
Icelk
15µA
VCEsat
1.08V
Max. leakage current
On-state voltage
Reverse voltage (internal diode)
POWER CIRCUIT
LABEL
-Ut
See fig. 5
@Ie=50A
See fig. 6
1.12V
Max. inductive load
(load + line length)
@Ie=50A
Tj=125°C
5mH
Overvoltage protection
@Ie=50A
Activ Clamp Protection
Shorts-circuits/Overload protection
Nominal desaturation current
detection
See fig. 8
Automatic Desaturation detection
Ice desat
225A
Min Desaturation detection time
@Tj=25°C
7µs
Max. single pulse avalanche energy
Eep
20J
@tpulse=1ms
Max. repetitive pulse avalanche
energy
Eep
5J
@Ie=50A
Typ. output capacitance
Cout
1.65nf
@Uc=0
IGBT junction/case thermal
resistance
Rthjc
0.054K/W
See fig. 7
Reverse diode junction/case
thermal resistance
Rthjc
0.11K/W
See fig. 7
Built-in heatsink thermal
resistance vertically mounted
Rthra
2.4K/W
@Tra=65°C
Heatsink thermal time constant
Tthra
30min
@Tra=65°C
Maximum junction temperature
Tjmax
105°C
@Ie=50A
Storage temperature
Tstg
-40->+85°C
Operating temperature
Tamb
-40->+70°C
Hr
5 à 95%
Ambient humidity
(*1)
To have a good diagnostic operation, we recommend a minimum load current of 2Amps.
Proud to serve you
Data given at Tambient=40°C and subject to modification without previous notice
®
celduc
r
e
l
a
i
s
celduc®
r
e
l
a
i
S/CON/SDI0501710/A/07/04/16
s
Page 5/11 GB
Fig. 4
POWER DISSIPATION AND LOAD CURRENT LIMIT VS TEMPERATURE
Please refere to the installation notice for
precautions about mounting the device on a heatsink.
Fig. 5
IGBT DROP OUT VOLTAGE
Fig. 6
REVERSE DIODE DROP OUT VOLTAGE
Fig. 7
POWER ELEMENT TRANSCIENT THERMAL
IMPEDANCE vs. PULSE DURATION
Fig. 8
ON-STATE PEAK OVERLOAD CURRENT vs. PULSE
DURATION
Proud to serve you
Data given at Tambient=40°C and subject to modification without previous notice
®
celduc
r
e
l
a
i
s
celduc®
r
e
l
a
i
S/CON/SDI0501710/A/07/04/16
s
Page 6/11 GB
DIAGNOSTIC & STATUS OUTPUTS
DIAGNOSTIC & STATUS OUTPUTS
CHARACTERISTIC
LABEL
VALUE
X4/5 & X4/6 (Diagnostic Output)
X4/3 & X4/4 (Status Output)
Marking
Semiconductor (Photo-MOS)
NO Contact (“Opened" without activation or supply)
Type of contact
Nominal switching voltage
72/96/110Vdc
Max. switching voltage
137.5Vdc
Min. switching voltage
16.8Vdc
Max. switching current
50mA
Min. switching current
0.1mA
Max. on-state resistance
INFO.
35Ω
Rds_on
Overvoltage protection
Transient voltage suppressor
Overload and shorts-circuits
protection
Thermistor
Reverse polarity protection
Proud to serve you
Data given at Tambient=40°C and subject to modification without previous notice
YES
®
celduc
r
e
l
a
i
s
celduc®
r
e
l
a
i
S/CON/SDI0501710/A/07/04/16
s
Page 7/11 GB
TIME CHARACTERISTICS
Fig. 2
TIME DIAGRAMS
TIME CHARACT.
CHARACTERISTIC
LABEL
VALUE
Turn on time
ton
1ms
Turn on delay
tdon
1.5ms
Turn off time
toff
300µs
Turn off delay
tdoff
1.5ms
F(on-off)
1Hz
Max. On-Off frequency
INFO.
Rload=20Ω
Lload=5mH
Ue=750Vdc
Rload=20Ω
Lload=5mH
Ue=750Vdc
GENERAL INFORMATION
WIRING
Connections
Type
Tightening torque
Recommended wiring type
Plastic material housing
Power
Control
M6 Hexagonal screw
Cage spring with manual
lever plug
3.75Nm
By pushing with DIN 5264
Screwdriver 0.4x2.5
round tabs, eyelet type, M6
1x1.5mm2 max
WELLAMID 6600 PA66 HWV0CP
Mounting
4 screws M5
Noise level
No audible noise
Weight
Proud to serve you
Data given at Tambient=40°C and subject to modification without previous notice
See mounting
sheet
1050g
®
celduc
r
e
l
a
i
s
celduc®
r
e
l
a
i
S/CON/SDI0501710/A/07/04/16
s
Page 8/11 GB
STANDARDS
GENERAL
Standards
EN50155
Temperature class
TX
Protection level
IP00
CE marking
Yes
UL, cULUS and VDE approvals
Possible on request
Reliability
MTTF = 118 years
MTTFd ≥ 24 years
Standards
EN50124-1
OV4 @72-96Vdc
OV3 @110Vdc
Overvoltage categories
INSULATION
Pollution Degree
PD2
Rated impulse voltage between
Input and Power outputs
Uni
8kV
Rated insulation voltage between
Input and Power outputs
Unm
0.9kV
Rated impulse voltage between
different signals of X4 connector
(supply, control input, Diagnostic
output and Status output)
2.5kV
Rated impulse voltage between
Power output and ground
(Aluminum baseplate)
(*3)
E.M.C.
IMMUNITY
E.M.C.
EMISSION
4kV(*3)
Warning: The rated impulse voltage test can damage the reliability of some components, we invite you to do this insulation test with reduced voltages (1500Vpk).
STANDARD
RESULTS
TESTS
STANDARD
E.S.D. (Electrostatic discharges)
EN50121-3-2
PASS
EN61000-4-2
Radiated electromagnetic fields
EN50121-3-2
PASS
EN61000-4-3
Fast transients bursts
EN50121-3-2
PASS
EN61000-4-4
Electric chocks
EN50121-3-2
PASS
EN61000-4-5
Radio-frequency fields
EN50121-3-2
PASS
EN61000-4-6
Radiated and conducted
disturbances
EN50121-3-2
PASS
EN55011
Fire & smoke protection
EN45545-2
HL2 with requirement R22
EN61373
PASS
TYPE OF TEST
OTHERS
ISO13849-1
@40°C/750Vdc
and 50A
Mechanical test
Shocks and Vibrations
Proud to serve you
Data given at Tambient=40°C and subject to modification without previous notice
®
celduc
r
e
l
a
i
s
celduc®
r
e
l
a
i
S/CON/SDI0501710/A/07/04/16
s
Page 9/11 GB
DIMENSIONS
Fig. 8
Proud to serve you
Data given at Tambient=40°C and subject to modification without previous notice
DIMENSIONS (in mm)
®
celduc
r
e
l
a
i
s
celduc®
r
e
l
a
i
S/CON/SDI0501710/A/07/04/16
s
Page 10/11 GB
CONNECTIONS-WIRING
CONTROL CONNECTOR
GROUND WIRING
X4/1
X4/10
==>Spring connector
« PUSH IN »
The Ground-wiring of the product with the rest of installation is
made by screwing directly to the relay baseplate with one of
the 4 holes (M5).
Fastening screws and round terminals (power, ground…) are
not supplied with the product.
POWER WIRING
X11 +
X12 -
Locking of plastic covers by screws CHC M3
Maximum tightening torque: 1.0Nm
B max=12mm
d min=6.2mm
N max=7mm
Proud to serve you
Data given at Tambient=40°C and subject to modification without previous notice
®
celduc
r
e
l
a
i
s
celduc®
r
e
l
a
i
S/CON/SDI0501710/A/07/04/16
s
Page 11/11 GB
OPTIONS
Control connector with screws :
Connection kit for large cable ends :
Possibility of current measurement output
(isolated) on signal connector (pin X4/9 and
X4/10):
Please consult our website for other accessory
references
(Heatsink, mounting adaptors, thermal grease…).
®
celduc
r
e
l
a
i
www.celduc.com
s
5 Rue Ampère B.P. 30004
42290 SORBIERS - FRANCE
E-Mail : [email protected]
Fax +33 (0) 4 77 53 85 51
Service Commercial France Tél. : +33 (0) 4 77 53 90 20
Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19