SPECIFICATIONS INTRODUCTIONS 1. Maximum leakage current each line-to-ground @ 115VAC 60Hz: 0.25mA @ 250VAC 50Hz: 0.45mA 2. Hipot rating (one minute) line-to-ground: 2250VDC line-to-line: 1450VDC 3. Operating frequency: 50/60Hz 4. Rated voltage: 115/250VAC 1. Designed as a general purpose filter with a fuse holder providing effective EMI suppression for both common and differential mode noise. 2. All part numbers are UL recognized, CSA certified and VDE approved. 3. Bleeder resistor is added with suffix "-R". 4. With optional Y CAP. from 100pF ~ 4700pF. COMPONENTS SERIES DIMENSIONS Cx (uF) 0.1 L (mH) 4.0 1.8 0.8 Cy (pF) R( ) 3300 1M DELTA PART NO. MINIMUM INSERTION LOSS IN dB COMMON MODE (L-G) IN 50 OHM SYSTEM CURRENT FREQUENCY-MHz RATING .15 .50 1.0 5.0 10 2A 29 38 40 42 43 4A 19 30 32 42 42 6A 13 22 26 38 42 DIFFERENTIAL MODE (L-L) IN 50 OHM SYSTEM 2A 5 19 28 48 51 4A 5 14 21 48 48 6A 5 12 15 40 46 30 41 39 38 Cx L F Cy N EG3F 06BEEG3F EG3F 2.263 2.106 1.66 1.42 1.74 57.5 53.5 42.0 36.0 44.0 COMMON MODE COMMON MODE 04BEEG4F 06BEEG3F DIFF. MODE DIFF. MODE 80 dB 50 42 38 60 dB 40 dB Cy R 04BEEG3F 0 dB 1M 100K 10K 10M N' G' 1.122 28.5 MECHANICAL CONSTRUCTION D G 20 dB L' L O A D E MAX. C MAX. B MAX. 1.283 32.6 A MAX. M3 R0.14 R3.5 1.142 0.004 29.0 0.1 F EG3F Use only with a 250V fuse Employer uniquement avec un fusible de 250V POWER ENTRY MODULE FILTERS L I N E 02BEEG3F INSERTION LOSS (TYPICAL) ELECTRICAL SCHEMATIC L DIMENSIONS IN INCHES/mm A B C D E STYLE 1.417 0.004 36.0 0.1 PART NO. 02BEEG3F/-R 04BEEG3F/-R 06BEEG3F/-R V D E DUAL-FUSE CONNECTOR FILTERS SERIES BEEG3F 1.303 0.004 33.1 0.1 SUGGESTED MOUNTING CUTOUT (MOUNTING FROM FRONT) 4-6 UNIT: INCH mm