Click Here to download this file: /data/apnotes/acan-27.pdf

www.murata-ps.com
D1U-12-CONC
D1U-12 Connector Card Application Note
PRODUCT OVERVIEW
This Output Connector card can be used to connect the D1U or D1U4 power supplies for bringing out the output voltage and signals for bench evaluation. Customers can also use
this card as an interface to their applications.
SAFETY PRECAUTION
This D1U-12-CONC output connector card is intended to facilitate the connection for the user to evaluate the D1U or D1U4 power supplies in
the laboratory. There is 12V exposed on this output connector card, please take the necessary safety precautions during your product evaluation.
SCHEMATIC - D1U-12-CONC
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
09 Nov 2012
ACAN27.A02 Page 1 of 3
D1U-12-CONC
D1U-12 Connector Card Application Note
SIGNAL SPECIFICATION
High Level
Low Level
Pin Assignment
Signal Name
Description
D2
P_Good
Power good signal output (Internal pull up is 5kΩ to Vsb)
A1
+SENSE1
VOUT remote sense, positive node input, connected to the
+ve load point
A2
-SENSE1
VOUT remote sense, negative node input connected to the
-ve load point
A6
PS_ON
Internal 1K ohm pull-up to Vsb, (accepts open collector/ drain >2.1V (open, or Vsb) <0.7V
-1 mA -4 mA
drive), This signal to be pulled low to turn-on power supply
(active, PS:On)
B5
PS_Kill
Floating pin will turn off P/S (shorter pin, last-make and
first-break contact for hot plugging). This signal overrides
PS-On in disabling the main output
>2.1V
<0.7V
N/A
(open, or Vsb) (active, PS:On)
Present
Internally tied to Vsb return
0V
N/C
No Connection
N/C
No Connection
N/C
No Connection
D1
AC_OK
Input AC Voltage “OK” signal output (Internal pull up is 5kΩ
to Vsb)
C5, C6, D5, D6
V_SB
Standby voltage output
B6
I Max
>2.4V (active, Good) <0.4V -2 mA +4 mA
>2.4V (active, OK)
<0.4V
-2 mA +4 mA
There is a jumper already installed between PS_Kill and Gnd.
There is a switch already installed to toggle the PS_ON to Gnd for enabling the power supply.
www.murata-ps.com/support
09 Nov 2012
ACAN27.A02 Page 2 of 3
D1U-12-CONC
D1U-12 Connector Card Application Note
MECHANICAL DIMENSIONS - D1U-12-CONC
J2
OFF
ON
R5
J6
R6
R7
ADR0
R8
GND
PS_KILL
+V12
TP2
P_GOOD
+SNS1
-SNS1
P_ENABLE
PS_KILL
PRESENT
RESET
P_FAULT
R_SENSE
AC_OK
+V3P3/
(5V)
+
S2
TP7
I_SHARE
GND
P_ENABLE
J21
JP1
TP3
V3P3/(+5V)
V3P3/
(+5V)
J8
GND
S1
J9
GND
V3P3/(+5V)
OUTPUT
RIPPLE
GND
J7
I2C_DATA
GND
I2C_CLK
TP6
J1
GND
J4
1
+V12
J5
+V12
V12 OUTPUT
RIPPLE
1
N/C
N/C
V3P3_
TRIM
12VRTN
3VRTN
V12
EXT_
RESET
V12_
TRIM
V3P3
V_CUR _SEN
J18
J19
Dimensions: 3" x 5"
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
This product is subject to the following operating requirements
and the Life and Safety Critical Application Sales Policy:
Refer to: http://www.murata-ps.com/requirements/
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2012 Murata Power Solutions, Inc.
www.murata-ps.com/support
09 Nov 2012
ACAN27.A02 Page 3 of 3