Transient Voltage Suppression Diodes Axial Leaded – 5000W > 5KP-HR series 5KP-HR Series RoHS Pb e3 Description Uni-directional The 5KP-HR High Reliability Series is designed specifically to protect sensitive electronic equipment from voltage transients induced by lightning and other transient voltage events. Features Bi-directional • Glass passivated chip junction in P600 package • 5000W peak pulse capability at 10/1000μs waveform, repetition rate (duty cycles):0.01% • Fast response time: typically less than 1.0ps from 0 Volts to BV min • Excellent clamping capability • Typical failure mode is short from over-specified voltage or current • Whisker test is conducted based on JEDEC JESD201A per its table 4a and 4c • IEC-61000-4-2 ESD 30kV(Air), 30kV (Contact) • ESD protection of data lines in accordance with IEC 61000-4-2 (IEC801-2) • EFT protection of data lines in accordance with IEC 61000-4-4 (IEC801-4) Agency Approvals AGENCY AGENCY FILE NUMBER E128662/E230531 Maximum Ratings and Thermal Characteristics (TA=25OC unless otherwise noted) Parameter Symbol Value Unit PPPM 5000 W PD 8.0 W IFSM 400 A VF 3.5/5.0 V TJ , TSTG -55 to 175 °C Typical Thermal Resistance Junction to Lead RuJL 8.0 °C/W Typical Thermal Resistance Junction to Ambient RuJA 40 °C/W Peak Pulse Power Dissipation by 10/1000μs Test Waveform (Fig.2) (Note 1) Steady State Power Dissipation on Infinite Heat Sink at TL=75ºC (Fig. 6) Peak Forward Surge Current, 8.3ms Single Half Sine Wave Unidirectional Only (Note 2) Maximum Instantaneous Forward Voltage at 100A for Unidirectional Only (Note 3) Operating Junction and Storage Temperature Range • Low incremental surge resistance • Typical IR less than 2μA when VBR min>12V • High temperature soldering guaranteed: 260C/10 seconds / 0.375”, (9.5mm) lead length, 5 lbs., (2.3kg) tension • VBR @ TJ= VBR@25°C x (1+αT x (TJ - 25)) (αT:Temperature Coefficient, typical value is 0.1%) • Plastic package has underwriters laboratory flammability classification 94V-O • Lead-free matte tin plated package • Halogen free and RoHS compliant Applications TVS devices are ideal for the protection of I/O interfaces, VCC bus and other vulnerable circuits used in telecom, computer, industrial and consumer electronic applications. Notes: 1. Non-repetitive current pulse , per Fig. 4 and derated above TJ (initial) =25OC per Fig. 3. 2.Measured on 8.3ms single half sine wave or equivalent square wave, duty cycle=4 per minute maximum. 3.VF < 3.5V for single die parts and VF< 5.0V for stacked-die parts. Functional Diagram Bi-directional Cathode Anode Uni-directional 5KP-HR Series 1 71 ©2015 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 03/06/15 Transient Voltage Suppression Diodes Axial Leaded – 5000W > 5KP-HR series Electrical Characteristics (T =25°C unless otherwise noted) A Part Number (Uni) Part Number (Bi) Reverse Stand off Voltage VR (Volts) 5KP5.0A-HR 5KP6.0A-HR 5KP6.5A-HR 5KP7.0A-HR 5KP7.5A-HR 5KP8.0A-HR 5KP8.5A-HR 5KP9.0A-HR 5KP10A-HR 5KP11A-HR 5KP12A-HR 5KP13A-HR 5KP14A-HR 5KP15A-HR 5KP16A-HR 5KP17A-HR 5KP18A-HR 5KP20A-HR 5KP22A-HR 5KP24A-HR 5KP26A-HR 5KP28A-HR 5KP30A-HR 5KP33A-HR 5KP36A-HR 5KP40A-HR 5KP43A-HR 5KP45A-HR 5KP48A-HR 5KP51A-HR 5KP54A-HR 5KP58A-HR 5KP60A-HR 5KP64A-HR 5KP70A-HR 5KP75A-HR 5KP78A-HR 5KP85A-HR 5KP90A-HR 5KP100A-HR 5KP110A-HR 5KP120A-HR 5KP130A-HR 5KP150A-HR 5KP160A-HR 5KP170A-HR 5KP180A-HR 5KP190A-HR 5KP200A-HR 5KP210A-HR 5KP220A-HR 5KP5.0CA-HR 5KP6.0CA-HR 5KP6.5CA-HR 5KP7.0CA-HR 5KP7.5CA-HR 5KP8.0CA-HR 5KP8.5CA-HR 5KP9.0CA-HR 5KP10CA-HR 5KP11CA-HR 5KP12CA-HR 5KP13CA-HR 5KP14CA-HR 5KP15CA-HR 5KP16CA-HR 5KP17CA-HR 5KP18CA-HR 5KP20CA-HR 5KP22CA-HR 5KP24CA-HR 5KP26CA-HR 5KP28CA-HR 5KP30CA-HR 5KP33CA-HR 5KP36CA-HR 5KP40CA-HR 5KP43CA-HR 5KP45CA-HR 5KP48CA-HR 5KP51CA-HR 5KP54CA-HR 5KP58CA-HR 5KP60CA-HR 5KP64CA-HR 5KP70CA-HR 5KP75CA-HR 5KP78CA-HR 5KP85CA-HR 5KP90CA-HR 5KP100CA-HR 5KP110CA-HR 5KP120CA-HR 5KP130CA-HR 5KP150CA-HR 5KP160CA-HR 5KP170CA-HR 5KP180CA-HR 5KP190CA-HR 5KP200CA-HR 5KP210CA-HR 5KP220CA-HR 5.0 6.0 6.5 7.0 7.5 8.0 8.5 9.0 10.0 11.0 12.0 13.0 14.0 15.0 16.0 17.0 18.0 20.0 22.0 24.0 26.0 28.0 30.0 33.0 36.0 40.0 43.0 45.0 48.0 51.0 54.0 58.0 60.0 64.0 70.0 75.0 78.0 85.0 90.0 100.0 110.0 120.0 130.0 150.0 160.0 170.0 180.0 190.0 200.0 210.0 220.0 Breakdown Voltage VBR (Volts) @ IT MIN MAX Test Current IT (mA) 6.40 6.67 7.22 7.78 8.33 8.89 9.44 10.00 11.10 12.20 13.30 14.40 15.60 16.70 17.80 18.90 20.00 22.20 24.00 26.70 28.90 31.10 33.30 36.70 40.00 44.40 47.80 50.00 53.30 56.70 60.00 64.40 66.70 71.10 77.80 83.30 86.70 94.40 100.00 110.00 122.00 133.00 144.00 167.00 178.00 189.00 200.00 211.00 222.00 233.00 244.00 7.00 7.37 7.98 8.60 9.21 9.83 10.40 11.10 12.30 13.50 14.70 15.90 17.20 18.50 19.70 20.90 22.10 24.50 26.90 29.50 31.90 34.40 36.80 40.60 44.20 49.10 52.80 55.30 58.90 62.70 66.30 71.20 73.70 78.60 86.00 92.10 95.80 104.00 111.00 123.00 135.00 147.00 159.00 185.00 197.00 209.00 221.00 233.00 246.00 258.00 270.00 50 50 50 50 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Maximum Clamping Voltage VC @ IPP (V) Maximum Peak Pulse Current IPP (A) Maximum Reverse Leakage IR @ VR (µ A) 9.2 10.3 11.2 12.0 12.9 13.6 14.4 15.4 17.0 18.2 19.9 21.5 23.2 24.4 26.0 27.6 29.2 32.4 35.5 38.9 42.1 45.4 48.4 53.3 58.1 64.5 69.4 72.7 77.4 82.4 87.1 93.6 96.8 103.0 113.0 121.0 126.0 137.0 146.0 162.0 177.0 193.0 209.0 243.0 259.0 275.0 292.0 310.0 329.2 349.5 371.1 554.3 495.1 455.4 425.0 395.3 375.0 354.2 331.2 300.0 280.2 256.3 237.2 219.8 209.0 196.2 184.8 174.7 157.4 143.7 131.1 121.1 112.3 105.4 95.7 87.8 79.1 73.5 70.2 65.9 61.9 58.6 54.5 52.7 49.5 45.1 42.1 40.5 37.2 34.9 31.5 28.8 26.4 24.4 21.0 19.7 18.5 17.5 16.5 15.5 14.6 13.7 5000 5000 2000 1000 250 150 50 20 15 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Agency Approval X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X Note: 1. For bidirectional type having VR of 10 volts and less, the IR limit is double. 2. Each lot of parts will pass group B test requirement. 5KP-HR Series 272 ©2015 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 03/06/15 Transient Voltage Suppression Diodes Axial Leaded – 5000W > 5KP-HR series Screen Process 100% Vision Inspection MIL-STD-750 method 2074 100% High Temperature Storage Life (168hrs,175°C) MIL-STD-750 method 1031 100% Temperature Cycle Test (-55 to150°C, 20 cycles, dwell time 15 min) MIL-STD-750 method 1051 100% Surge Test (2x) MIL-STD-750 method 4066 100% HTRB 150°C Bias=VR(80% breakdown voltage, 96hrs, and each direction at 96 hrs for Bi-directional products) MIL–STD–750 method 1038 Final Electrical Test( 100% 3 sigma limit, 100% dynamic test and PAT limit) MIL-STD-750 method 4016.4021.4011 Note: Up-screen program can be specified by customer’s request via contacting Littlefuse service Group B Test Requirement Screen Surge test Burn - In (HTRB) Method Condition Requirement 10/1000 µs Peak Pluse Waveform Maximum clamping Voltage (VC) @ Peak Plus Current (IPP) Sample Size 45 perform 10x Accept 0 failures MIL -STD-750, Method 1038.5 Applied voltage 100% VR@150°C Sample size 45 340 hours (680 hours for bi-direction products, each direction 340 hours) Accept 0 failures -- IR@VR, V(BR)@IT Sample size 45 Accept 0 failures Electrical test I-V Curve Characteristics Bi-directional Uni-directional Ipp Vc VBR VR IR VF IT Vc VBR VR V IT IR VR VBR Vc V Ipp Ipp PPPM VR VBR VC IR VF IR IT Peak Pulse Power Dissipation -- Max power dissipation Stand-off Voltage -- Maximum voltage that can be applied to the TVS without operation Breakdown Voltage -- Maximum voltage that flows though the TVS at a specified test current (IT) Clamping Voltage -- Peak voltage measured across the TVS at a specified Ippm (peak impulse current) Reverse Leakage Current -- Current measured at VR Forward Voltage Drop for Uni-directional 5KP-HR Series 3 73 ©2015 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 03/06/15 Transient Voltage Suppression Diodes Axial Leaded – 5000W > 5KP-HR series Ratings and Characteristic Curves (T =25°C unless otherwise noted) A Figure 1 - TVS Transients Clamping Waveform Figure 2 - Peak Pulse Power Rating Curve 1000 Voltage Transients PPPM-Peak Pulse Power (KW) Voltage Across TVS Voltage or Current TJ initial = Tamb Current Through TVS 100 5kW at 10x1000µs, 25°C 10 1 0.01 0.001 150 100 IPPM- Peak Pulse Current, % IRSM Peak Pulse Power (PPP) or Current (IPP) Derating in Percentage % 75 50 25 0 25 50 75 100 125 150 175 200 tr=10µsec TJ=25°C Pulse Width(td) is defined as the point where the peak current decays to 50% of IPPM Peak Value IPPM 100 Half Value IPPM IPPM ( ) 2 50 0 TJ - Initial Junction Temperature (ºC) 10/1000µsec. Waveform as defined by R.E.A td 1.0 0 2.0 3.0 4.0 t-Time (ms) Figure 5 - Typical Junction Capacitance Figure 6 - Typical Transient Thermal Impedance 100 100000 10000 Transient Thermal Impedance (°C/W) Uni-direconal V=0V Cj (pF) 10 Figure 4 - Pulse Waveform Figure 3 - Peak Pulse Power Derating Curve Bi-direconal V=0V Uni-direconal V=VR 1000 100 Bi-direconal V=VR 10 1 1 10 100 10 1 0.1 1000 0.01 VBR - Reverse Breakdown Voltage (V) 5KP-HR Series 1 td-Pulse Width (Sec.) Time 0 0.1 0.1 1 10 100 1000 TP - Pulse Duration (s) 4 74 ©2015 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 03/06/15 Transient Voltage Suppression Diodes Axial Leaded – 5000W > 5KP-HR series Figure 7 - Maximum Non-Repetitive Peak Forward Surge Current Uni-Directional Only Figure 8 - Peak Forward Voltage Drop vs Peak Forward Current (Typical Values) Single die 100 450 IF- Peak Forward Current(A) IFSM - Peak Forward Surve Current (A) 500 400 350 300 250 200 150 100 50 10 Stacked-die 1 0.1 0.01 0 1 10 0.0 100 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 VF-Peak Forward Voltage(V) Number of Cycles at 60 Hz Environmental Specifications Physical Specifications Weight 0.07oz., 2.1g High Temp. Storage JESD22-A103 Case P600 molded plastic body over passivated junction. HTRB JESD22-A108 Polarity Color band denotes the cathode except Bipolar. Temperature Cycling JESD22-A104 Terminal Matte Tin axial leads, solderable per JESD22-B102. H3TRB JESD22-A101 RSH JESD22-B106 Dimensions D Dimensions Cathode Band (for Uni-directional products only) C A B A Inches Min Millimeters Max Min Max A 1.000 - 25.40 - B 0.340 0.360 8.60 9.10 C 0.048 0.052 1.22 1.32 D 0.340 0.360 8.60 9.10 P600 5KP-HR Series 5 75 ©2015 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 03/06/15 Transient Voltage Suppression Diodes Axial Leaded – 5000W > 5KP-HR series Part Numbering System Part Marking System Cathode Band (for Uni-directional products only) HIGH RELIABILITY TYPE CODE: A Uni-Directional (5% VBR Voltage Tolerance) CA Bi-Directional (5% VBR Voltage Tolerance) F 5KPxxx XX -HR YYWW Trace Code Marking Littelfuse Logo YY:Year Code WW: Week Code 5KPXXX-HR VR VOLTAGE Product Type SERIES CODE Packing Options Part Number Component Package Quantity Packaging Option 5KPxxxXX-HR P600 800 Tape & Reel Packaging Specification EIA STD RS-296 Tape and Reel Specification Off Center either side 2.063+0.079/-0.039 (53.0+2.0/-1.0) 0.028(0.7) 2.56 (65.0) 0.047 (1.2) 0.394+/-0.020 (10.0+/-0.5) 13.0 (330.2) 0.236 (6.0) Dimensions are in inches/mm 3.0 (76.2) 0.68 (17.27) 2.75 (69.85) Recess Depth Max. 0.75 (19.05) 5KP-HR Series Direction of Feed 6 76 ©2015 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 03/06/15