Datasheet

Transient Voltage Suppression Diodes
Axial Leaded – 30000W > 30KPA-HR series
30KPA-HR Series
RoHS
Pb e3
Descriptios
Uni-directional
The 30KPA-HR High Reliability Series is designed
specifically to protect sensitive electronic equipment from
voltage transients induced by lightning and other transient
voltage events.
Features
Bi-directional
• Glass passivated chip
junction in P600 package
• 30000W peak pulse
capability at 10/1000μs
waveform, repetition rate
(duty cycles):0.01%
• Fast response time:
typically less than 1.0ps
from 0 Volts to BV min
• Excellent clamping
capability
• Typical failure mode is
short from over-specified
voltage or current
• Whisker test is conducted
based on JEDEC
JESD201A per its table 4a
and 4c
• IEC-61000-4-2 ESD
30kV(Air), 30kV (Contact)
• ESD protection of data
lines in accordance with
IEC 61000-4-2 (IEC801-2)
• EFT protection of data
lines in accordance with
IEC 61000-4-4 (IEC801-4)
Agency Approvals
AGENCY
AGENCY FILE NUMBER
E230531
Maximum Ratings and Thermal Characteristics
(TA=25OC unless otherwise noted)
Parameter
Symbol
Value
Unit
PPPM
30000
W
Steady State Power Dissipation on
Infinite Heat Sink at TL=75ºC (Fig. 5)
PD
8.0
W
Peak Forward Surge Current, 8.3ms
Single Half Sine Wave Unidirectional
Only (Note 2)
IFSM
400
A
TJ , TSTG
-55 to 175
°C
Typical Thermal Resistance Junction
to Lead
RuJL
8.0
°C/W
Typical Thermal Resistance Junction
to Ambient
RuJA
40
°C/W
Peak Pulse Power Dissipation by
10/1000μs Test Waveform (Fig.2)
(Note 1)
Operating Junction and Storage
Temperature Range
• Low incremental surge
resistance
• Typical IR less than 2μA
when VBR min>73V
• High temperature
soldering guaranteed:
260C/10 seconds / 0.375”,
(9.5mm) lead length, 5
lbs., (2.3kg) tension
• VBR @ TJ= VBR@25°C
x (1+αT x (TJ - 25))
(αT:Temperature
Coefficient, typical value
is 0.1%)
• Plastic package has
underwriters laboratory
flammability classification
94V-O
• Lead-free matte tin plated
package
• Halogen free and RoHS
compliant
Applications
TVS devices are ideal for the protection of I/O interfaces,
VCC bus and other vulnerable circuits used in telecom,
computer, industrial and consumer electronic applications.
Notes:
1. Non-repetitive current pulse , per Fig. 4 and derated above TJ (initial) =25OC per Fig. 3.
2.Measured on 8.3ms single half sine wave or equivalent square wave, duty cycle=4 per
minute maximum.
Functional Diagram
Bi-directional
Cathode
Anode
Uni-directional
30KPA-HR Series
1
85
©2015 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 03/06/15
Transient Voltage Suppression Diodes
Axial Leaded – 30000W > 30KPA-HR series
Electrical Characteristics (T =25°C unless otherwise noted)
A
MAX
Test
Current
IT
(mA)
Maximum
Peak
Pulse Current
Ipp (A)
Maximum
Reverse
Leakage
IR @VR
(µ A)
Maximum
Clamping
Voltage
VC @ IPP
(V)
34.41
36.86
40.59
44.22
47.96
51.59
52.80
55.33
58.96
62.70
66.33
71.28
73.70
78.65
81.07
86.02
87.23
88.44
92.18
50
50
50
50
20
10
10
5
5
5
5
5
5
5
5
5
5
5
5
606.0
548.9
517.9
490.3
450.9
420.8
415.1
391.5
371.3
350.7
331.5
327.9
297.1
291.3
283.2
278.0
271.7
265.8
253.8
5000
5000
5000
5000
2000
1000
1000
250
150
50
20
20
15
10
2
2
2
2
2
50.0
55.2
58.5
61.8
67.2
72.0
73.0
77.4
81.6
86.4
91.4
92.4
102.0
104.0
107.0
109.0
111.5
114.0
119.4
87.10
93.80
100.50
107.20
113.90
120.60
134.00
147.40
160.80
167.60
174.30
178.70
187.70
189.90
201.10
95.81
103.18
110.55
117.92
125.29
132.66
147.40
162.14
176.88
184.36
191.73
196.57
206.47
208.89
221.21
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
234.9
217.7
207.0
194.2
183.0
172.9
155.9
142.3
135.8
129.8
123.7
120.0
111.2
110.2
104.3
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
129.0
139.2
146.4
156.0
165.6
175.2
194.4
213.0
223.2
233.4
245.0
252.6
272.4
275.0
290.4
221.20
241.30
268.10
288.20
290.40
301.60
312.80
321.70
334.00
243.32
265.43
294.91
317.02
319.44
331.76
344.08
353.87
367.40
5
5
5
5
5
5
5
5
5
94.7
86.9
78.3
72.8
72.8
69.5
65.3
64.5
62.0
2
2
2
2
2
2
2
2
2
319.8
348.6
387.0
416.4
416.0
436.2
464.0
469.9
484.0
Breakdown
Voltage VBR
(Volts) @ IT
Part
Number
(Uni)
Part
Number
(Bi)
Reverse
Stand off
Voltage VR
(Volts)
MIN
30KPA28A-HR
30KPA30A-HR
30KPA33A-HR
30KPA36A-HR
30KPA39A-HR
30KPA42A-HR
30KPA43A-HR
30KPA45A-HR
30KPA48A-HR
30KPA51A-HR
30KPA54A-HR
30KPA58A-HR
30KPA60A-HR
30KPA64A-HR
30KPA66A-HR
30KPA70A-HR
30KPA71A-HR
30KPA72A-HR
30KPA75A-HR
30KPA78A-HR
30KPA84A-HR
30KPA90A-HR
30KPA96A-HR
30KPA102A-HR
30KPA108A-HR
30KPA120A-HR
30KPA132A-HR
30KPA144A-HR
30KPA150A-HR
30KPA156A-HR
30KPA160A-HR
30KPA168A-HR
30KPA170A-HR
30KPA180A-HR
30KPA198A-HR
30KPA216A-HR
30KPA240A-HR
30KPA258A-HR
30KPA260A-HR
30KPA270A-HR
30KPA280A-HR
30KPA288A-HR
30KPA300A-HR
30KPA28CA-HR
30KPA30CA-HR
30KPA33CA-HR
30KPA36CA-HR
30KPA39CA-HR
30KPA42CA-HR
30KPA43CA-HR
30KPA45CA-HR
30KPA48CA-HR
30KPA51CA-HR
30KPA54CA-HR
30KPA58CA-HR
30KPA60CA-HR
30KPA64CA-HR
30KPA66CA-HR
30KPA70CA-HR
30KPA71CA-HR
30KPA72CA-HR
30KPA75CA-HR
28
30
33
36
39
42
43
45
48
51
54
58
60
64
66
70
71
72
75
31.28
33.51
36.90
40.20
43.60
46.90
48.00
50.30
53.60
57.00
60.30
64.80
67.00
71.50
73.70
78.20
79.30
80.40
83.80
30KPA78CA-HR
30KPA84CA-HR
30KPA90CA-HR
30KPA96CA-HR
30KPA102CA-HR
30KPA108CA-HR
30KPA120CA-HR
30KPA132CA-HR
30KPA144CA-HR
30KPA150CA-HR
30KPA156CA-HR
30KPA160CA-HR
30KPA168CA-HR
30KPA170CA-HR
30KPA180CA-HR
78
84
90
96
102
108
120
132
144
150
156
160
168
170
180
30KPA198CA-HR
30KPA216CA-HR
30KPA240CA-HR
30KPA258CA-HR
30KPA260CA-HR
30KPA270CA-HR
30KPA280CA-HR
30KPA288CA-HR
30KPA300CA-HR
198
216
240
258
260
270
280
288
300
Agency
Approval
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Note:
1. For bidirectional type having VR of 60 volts and less, the IR limit is double.
2. Each lot of parts will pass group B test requirement.
30KPA-HR Series
2
86
©2015 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 03/06/15
Transient Voltage Suppression Diodes
Axial Leaded – 30000W > 30KPA-HR series
Screen Process
100% Vision Inspection
MIL-STD-750 method 2074
100% High Temperature Storage Life (168hrs,175°C)
MIL-STD-750 method 1031
100% Temperature Cycle Test (-55 to150°C, 20 cycles, dwell time 15 min)
MIL-STD-750 method 1051
100% Surge Test (2x)
MIL-STD-750 method 4066
100% HTRB 150°C Bias=VR(80% breakdown voltage, 96hrs, and each direction
at 96 hrs for Bi-directional products)
MIL–STD–750 method 1038
Final Electrical Test( 100% 3 sigma limit, 100% dynamic test and PAT limit)
MIL-STD-750 method 4016.4021.4011
Note: Up-screen program can be specified by customer’s request via contacting Littlefuse service
Group B Test Requirement
Screen
Method
Condition
Requirement
Surge test
10/1000 µs Peak
Pluse Waveform
Maximum clamping
Voltage (VC) @ Peak
Plus Current (IPP)
Sample Size 45 perform 10x
Accept 0 failures
Burn - In
(HTRB)
MIL -STD-750,
Method 1038.5
Applied voltage
100% VR@150°C
Sample size 45
340 hours (680 hours for
bi-direction products, each
direction 340 hours)
Accept 0 failures
--
IR@VR, V(BR)@IT
Sample size 45
Accept 0 failures
Electrical test
I-V Curve Characteristics
Bi-directional
Uni-directional
Ipp
Vc VBR VR
IR VF
IT
Vc VBR VR
V
IT
IR
VR VBR Vc
V
Ipp
Ipp
PPPM
VR
VBR
VC
IR
VF
IR
IT
Peak Pulse Power Dissipation -- Max power dissipation
Stand-off Voltage -- Maximum voltage that can be applied to the TVS without operation
Breakdown Voltage -- Maximum voltage that flows though the TVS at a specified test current (IT)
Clamping Voltage -- Peak voltage measured across the TVS at a specified Ippm (peak impulse current)
Reverse Leakage Current -- Current measured at VR
Forward Voltage Drop for Uni-directional
30KPA-HR Series
873
©2015 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 03/06/15
Transient Voltage Suppression Diodes
Axial Leaded – 30000W > 30KPA-HR series
Ratings and Characteristic Curves (T =25°C unless otherwise noted)
A
Figure 1 - TVS Transients Clamping Waveform
Figure 2 - Peak Pulse Power Rating Curve
1000
PPPM-Peak Pulse Power (kW)
Voltage Transients
Voltage or Current
Voltage Across TVS
Current Through TVS
30kW at 10x1000µs, 25°C
100
10
TJ initial = Tamb
1
0.000001
0.00001
0.0001
0.001
td-Pulse Width (sec.)
Time
Figure 4 - Pulse Waveform
150
100
IPPM- Peak Pulse Current, % IRSM
Peak Pulse Power (PPP) or Current (IPP)
Derating in Percentage %
Figure 3 - Peak Pulse Power Derating Curve
75
50
25
0
0
25
50
75
100
125
150
175
200
Half Value
IPPM IPPM
( )
2
50
10/1000µsec. Waveform
as defined by R.E.A
td
1.0
0
2.0
3.0
4.0
t-Time (ms)
Figure 5 - Typical Junction Capacitance
Figure 6 - Typical Transient Thermal Impedance
100
10000
Transient Thermal Impedance (°C/W)
Uni-direconal V=0V
Bi-direconal V=0V
1000
Cj (pF)
TJ=25°C
Pulse Width(td) is defined
as the point where the peak
current decays to 50% of IPPM
Peak Value
IPPM
100
0
TJ - Initial Junction Temperature (ºC)
Uni-direconal V=VR
100
Bi-direconal V=VR
10
10
1
0.1
1
0
50
100
150
200
250
300
350
0.01
400
VBR - Reverse Breakdown Voltage (V)
30KPA-HR Series
tr=10µsec
0.1
1
10
100
1000
TP - Pulse Duration (s)
4
88
©2015 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 03/06/15
Transient Voltage Suppression Diodes
Axial Leaded – 30000W > 30KPA-HR series
Figure 8 - Peak Forward Voltage Drop vs Peak Forward
Current (Typical Values)
1000
100
900
800
IF - Peak Forward Current(A)
IFSM - Peak Forward Surve Current (A)
Figure 7 - Maximum Non-Repetitive Peak Forward
Surge Current Uni-Directional Only
700
600
500
400
300
200
4 stacked-die
5 stacked-die
10
1
100
0
1
10
0.1
100
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
VF - Peak Forward Voltage(V)
Number of Cycles at 60 Hz
Environmental Specifications
Physical Specifications
Weight
0.07oz., 2.5g
High Temp. Storage
JESD22-A103
Case
P600 molded plastic body over
passivated junction.
HTRB
JESD22-A108
Polarity
Color band denotes the cathode except
Bipolar.
Temperature Cycling
JESD22-A104
Terminal
Matte Tin axial leads, solderable per
JESD22-B102.
H3TRB
JESD22-A101
RSH
JESD22-B106
Dimensions
D
Cathode Band
(for Uni-directional products only)
Dimensions
C
A
B
A
P600
30KPA-HR Series
5
89
Inches
Min
Millimeters
Max
Min
Max
A
1.000
-
25.40
-
B
0.340
0.360
8.60
9.10
C
0.048
0.052
1.22
1.32
D
0.340
0.360
8.60
9.10
©2015 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 03/06/15
Transient Voltage Suppression Diodes
Axial Leaded – 30000W > 30KPA-HR series
Part Numbering System
Part Marking System
Cathode Band
HIGH RELIABILITY
(for Uni-directional
products only)
TYPE CODE:
A Uni-Directional (5% VBR Voltage Tolerance)
CA Bi-Directional (5% VBR Voltage Tolerance)
F
30KPA xxx XX -HR
YYWW
Trace Code Marking
Littelfuse Logo
30KPAXXX-HR
VR VOLTAGE
YY:Year Code
WW: Week Code
Product Type
SERIES CODE
Packing Options
Part Number
30KPAxxxXX-HR
Component
Package
Quantity
Packaging
Option
P600
800
Tape & Reel
Packaging Specification
EIA STD RS-296
Tape and Reel Specification
Off Center
either side 2.063+0.079/-0.039
(53.0+2.0/-1.0)
0.028(0.7)
2.56
(65.0)
0.047
(1.2)
0.394+/-0.020
(10.0+/-0.5)
13.0
(330.2)
0.236
(6.0)
Dimensions are in
inches/mm
3.0
(76.2)
0.68
(17.27)
2.75
(69.85)
Recess Depth Max. 0.75 (19.05)
30KPA-HR Series
Direction of Feed
6
90
©2015 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 03/06/15