Transient Voltage Suppression Diodes Axial Leaded – 30000W > 30KPA-HR series 30KPA-HR Series RoHS Pb e3 Descriptios Uni-directional The 30KPA-HR High Reliability Series is designed specifically to protect sensitive electronic equipment from voltage transients induced by lightning and other transient voltage events. Features Bi-directional • Glass passivated chip junction in P600 package • 30000W peak pulse capability at 10/1000μs waveform, repetition rate (duty cycles):0.01% • Fast response time: typically less than 1.0ps from 0 Volts to BV min • Excellent clamping capability • Typical failure mode is short from over-specified voltage or current • Whisker test is conducted based on JEDEC JESD201A per its table 4a and 4c • IEC-61000-4-2 ESD 30kV(Air), 30kV (Contact) • ESD protection of data lines in accordance with IEC 61000-4-2 (IEC801-2) • EFT protection of data lines in accordance with IEC 61000-4-4 (IEC801-4) Agency Approvals AGENCY AGENCY FILE NUMBER E230531 Maximum Ratings and Thermal Characteristics (TA=25OC unless otherwise noted) Parameter Symbol Value Unit PPPM 30000 W Steady State Power Dissipation on Infinite Heat Sink at TL=75ºC (Fig. 5) PD 8.0 W Peak Forward Surge Current, 8.3ms Single Half Sine Wave Unidirectional Only (Note 2) IFSM 400 A TJ , TSTG -55 to 175 °C Typical Thermal Resistance Junction to Lead RuJL 8.0 °C/W Typical Thermal Resistance Junction to Ambient RuJA 40 °C/W Peak Pulse Power Dissipation by 10/1000μs Test Waveform (Fig.2) (Note 1) Operating Junction and Storage Temperature Range • Low incremental surge resistance • Typical IR less than 2μA when VBR min>73V • High temperature soldering guaranteed: 260C/10 seconds / 0.375”, (9.5mm) lead length, 5 lbs., (2.3kg) tension • VBR @ TJ= VBR@25°C x (1+αT x (TJ - 25)) (αT:Temperature Coefficient, typical value is 0.1%) • Plastic package has underwriters laboratory flammability classification 94V-O • Lead-free matte tin plated package • Halogen free and RoHS compliant Applications TVS devices are ideal for the protection of I/O interfaces, VCC bus and other vulnerable circuits used in telecom, computer, industrial and consumer electronic applications. Notes: 1. Non-repetitive current pulse , per Fig. 4 and derated above TJ (initial) =25OC per Fig. 3. 2.Measured on 8.3ms single half sine wave or equivalent square wave, duty cycle=4 per minute maximum. Functional Diagram Bi-directional Cathode Anode Uni-directional 30KPA-HR Series 1 85 ©2015 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 03/06/15 Transient Voltage Suppression Diodes Axial Leaded – 30000W > 30KPA-HR series Electrical Characteristics (T =25°C unless otherwise noted) A MAX Test Current IT (mA) Maximum Peak Pulse Current Ipp (A) Maximum Reverse Leakage IR @VR (µ A) Maximum Clamping Voltage VC @ IPP (V) 34.41 36.86 40.59 44.22 47.96 51.59 52.80 55.33 58.96 62.70 66.33 71.28 73.70 78.65 81.07 86.02 87.23 88.44 92.18 50 50 50 50 20 10 10 5 5 5 5 5 5 5 5 5 5 5 5 606.0 548.9 517.9 490.3 450.9 420.8 415.1 391.5 371.3 350.7 331.5 327.9 297.1 291.3 283.2 278.0 271.7 265.8 253.8 5000 5000 5000 5000 2000 1000 1000 250 150 50 20 20 15 10 2 2 2 2 2 50.0 55.2 58.5 61.8 67.2 72.0 73.0 77.4 81.6 86.4 91.4 92.4 102.0 104.0 107.0 109.0 111.5 114.0 119.4 87.10 93.80 100.50 107.20 113.90 120.60 134.00 147.40 160.80 167.60 174.30 178.70 187.70 189.90 201.10 95.81 103.18 110.55 117.92 125.29 132.66 147.40 162.14 176.88 184.36 191.73 196.57 206.47 208.89 221.21 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 234.9 217.7 207.0 194.2 183.0 172.9 155.9 142.3 135.8 129.8 123.7 120.0 111.2 110.2 104.3 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 129.0 139.2 146.4 156.0 165.6 175.2 194.4 213.0 223.2 233.4 245.0 252.6 272.4 275.0 290.4 221.20 241.30 268.10 288.20 290.40 301.60 312.80 321.70 334.00 243.32 265.43 294.91 317.02 319.44 331.76 344.08 353.87 367.40 5 5 5 5 5 5 5 5 5 94.7 86.9 78.3 72.8 72.8 69.5 65.3 64.5 62.0 2 2 2 2 2 2 2 2 2 319.8 348.6 387.0 416.4 416.0 436.2 464.0 469.9 484.0 Breakdown Voltage VBR (Volts) @ IT Part Number (Uni) Part Number (Bi) Reverse Stand off Voltage VR (Volts) MIN 30KPA28A-HR 30KPA30A-HR 30KPA33A-HR 30KPA36A-HR 30KPA39A-HR 30KPA42A-HR 30KPA43A-HR 30KPA45A-HR 30KPA48A-HR 30KPA51A-HR 30KPA54A-HR 30KPA58A-HR 30KPA60A-HR 30KPA64A-HR 30KPA66A-HR 30KPA70A-HR 30KPA71A-HR 30KPA72A-HR 30KPA75A-HR 30KPA78A-HR 30KPA84A-HR 30KPA90A-HR 30KPA96A-HR 30KPA102A-HR 30KPA108A-HR 30KPA120A-HR 30KPA132A-HR 30KPA144A-HR 30KPA150A-HR 30KPA156A-HR 30KPA160A-HR 30KPA168A-HR 30KPA170A-HR 30KPA180A-HR 30KPA198A-HR 30KPA216A-HR 30KPA240A-HR 30KPA258A-HR 30KPA260A-HR 30KPA270A-HR 30KPA280A-HR 30KPA288A-HR 30KPA300A-HR 30KPA28CA-HR 30KPA30CA-HR 30KPA33CA-HR 30KPA36CA-HR 30KPA39CA-HR 30KPA42CA-HR 30KPA43CA-HR 30KPA45CA-HR 30KPA48CA-HR 30KPA51CA-HR 30KPA54CA-HR 30KPA58CA-HR 30KPA60CA-HR 30KPA64CA-HR 30KPA66CA-HR 30KPA70CA-HR 30KPA71CA-HR 30KPA72CA-HR 30KPA75CA-HR 28 30 33 36 39 42 43 45 48 51 54 58 60 64 66 70 71 72 75 31.28 33.51 36.90 40.20 43.60 46.90 48.00 50.30 53.60 57.00 60.30 64.80 67.00 71.50 73.70 78.20 79.30 80.40 83.80 30KPA78CA-HR 30KPA84CA-HR 30KPA90CA-HR 30KPA96CA-HR 30KPA102CA-HR 30KPA108CA-HR 30KPA120CA-HR 30KPA132CA-HR 30KPA144CA-HR 30KPA150CA-HR 30KPA156CA-HR 30KPA160CA-HR 30KPA168CA-HR 30KPA170CA-HR 30KPA180CA-HR 78 84 90 96 102 108 120 132 144 150 156 160 168 170 180 30KPA198CA-HR 30KPA216CA-HR 30KPA240CA-HR 30KPA258CA-HR 30KPA260CA-HR 30KPA270CA-HR 30KPA280CA-HR 30KPA288CA-HR 30KPA300CA-HR 198 216 240 258 260 270 280 288 300 Agency Approval X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X Note: 1. For bidirectional type having VR of 60 volts and less, the IR limit is double. 2. Each lot of parts will pass group B test requirement. 30KPA-HR Series 2 86 ©2015 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 03/06/15 Transient Voltage Suppression Diodes Axial Leaded – 30000W > 30KPA-HR series Screen Process 100% Vision Inspection MIL-STD-750 method 2074 100% High Temperature Storage Life (168hrs,175°C) MIL-STD-750 method 1031 100% Temperature Cycle Test (-55 to150°C, 20 cycles, dwell time 15 min) MIL-STD-750 method 1051 100% Surge Test (2x) MIL-STD-750 method 4066 100% HTRB 150°C Bias=VR(80% breakdown voltage, 96hrs, and each direction at 96 hrs for Bi-directional products) MIL–STD–750 method 1038 Final Electrical Test( 100% 3 sigma limit, 100% dynamic test and PAT limit) MIL-STD-750 method 4016.4021.4011 Note: Up-screen program can be specified by customer’s request via contacting Littlefuse service Group B Test Requirement Screen Method Condition Requirement Surge test 10/1000 µs Peak Pluse Waveform Maximum clamping Voltage (VC) @ Peak Plus Current (IPP) Sample Size 45 perform 10x Accept 0 failures Burn - In (HTRB) MIL -STD-750, Method 1038.5 Applied voltage 100% VR@150°C Sample size 45 340 hours (680 hours for bi-direction products, each direction 340 hours) Accept 0 failures -- IR@VR, V(BR)@IT Sample size 45 Accept 0 failures Electrical test I-V Curve Characteristics Bi-directional Uni-directional Ipp Vc VBR VR IR VF IT Vc VBR VR V IT IR VR VBR Vc V Ipp Ipp PPPM VR VBR VC IR VF IR IT Peak Pulse Power Dissipation -- Max power dissipation Stand-off Voltage -- Maximum voltage that can be applied to the TVS without operation Breakdown Voltage -- Maximum voltage that flows though the TVS at a specified test current (IT) Clamping Voltage -- Peak voltage measured across the TVS at a specified Ippm (peak impulse current) Reverse Leakage Current -- Current measured at VR Forward Voltage Drop for Uni-directional 30KPA-HR Series 873 ©2015 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 03/06/15 Transient Voltage Suppression Diodes Axial Leaded – 30000W > 30KPA-HR series Ratings and Characteristic Curves (T =25°C unless otherwise noted) A Figure 1 - TVS Transients Clamping Waveform Figure 2 - Peak Pulse Power Rating Curve 1000 PPPM-Peak Pulse Power (kW) Voltage Transients Voltage or Current Voltage Across TVS Current Through TVS 30kW at 10x1000µs, 25°C 100 10 TJ initial = Tamb 1 0.000001 0.00001 0.0001 0.001 td-Pulse Width (sec.) Time Figure 4 - Pulse Waveform 150 100 IPPM- Peak Pulse Current, % IRSM Peak Pulse Power (PPP) or Current (IPP) Derating in Percentage % Figure 3 - Peak Pulse Power Derating Curve 75 50 25 0 0 25 50 75 100 125 150 175 200 Half Value IPPM IPPM ( ) 2 50 10/1000µsec. Waveform as defined by R.E.A td 1.0 0 2.0 3.0 4.0 t-Time (ms) Figure 5 - Typical Junction Capacitance Figure 6 - Typical Transient Thermal Impedance 100 10000 Transient Thermal Impedance (°C/W) Uni-direconal V=0V Bi-direconal V=0V 1000 Cj (pF) TJ=25°C Pulse Width(td) is defined as the point where the peak current decays to 50% of IPPM Peak Value IPPM 100 0 TJ - Initial Junction Temperature (ºC) Uni-direconal V=VR 100 Bi-direconal V=VR 10 10 1 0.1 1 0 50 100 150 200 250 300 350 0.01 400 VBR - Reverse Breakdown Voltage (V) 30KPA-HR Series tr=10µsec 0.1 1 10 100 1000 TP - Pulse Duration (s) 4 88 ©2015 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 03/06/15 Transient Voltage Suppression Diodes Axial Leaded – 30000W > 30KPA-HR series Figure 8 - Peak Forward Voltage Drop vs Peak Forward Current (Typical Values) 1000 100 900 800 IF - Peak Forward Current(A) IFSM - Peak Forward Surve Current (A) Figure 7 - Maximum Non-Repetitive Peak Forward Surge Current Uni-Directional Only 700 600 500 400 300 200 4 stacked-die 5 stacked-die 10 1 100 0 1 10 0.1 100 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 VF - Peak Forward Voltage(V) Number of Cycles at 60 Hz Environmental Specifications Physical Specifications Weight 0.07oz., 2.5g High Temp. Storage JESD22-A103 Case P600 molded plastic body over passivated junction. HTRB JESD22-A108 Polarity Color band denotes the cathode except Bipolar. Temperature Cycling JESD22-A104 Terminal Matte Tin axial leads, solderable per JESD22-B102. H3TRB JESD22-A101 RSH JESD22-B106 Dimensions D Cathode Band (for Uni-directional products only) Dimensions C A B A P600 30KPA-HR Series 5 89 Inches Min Millimeters Max Min Max A 1.000 - 25.40 - B 0.340 0.360 8.60 9.10 C 0.048 0.052 1.22 1.32 D 0.340 0.360 8.60 9.10 ©2015 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 03/06/15 Transient Voltage Suppression Diodes Axial Leaded – 30000W > 30KPA-HR series Part Numbering System Part Marking System Cathode Band HIGH RELIABILITY (for Uni-directional products only) TYPE CODE: A Uni-Directional (5% VBR Voltage Tolerance) CA Bi-Directional (5% VBR Voltage Tolerance) F 30KPA xxx XX -HR YYWW Trace Code Marking Littelfuse Logo 30KPAXXX-HR VR VOLTAGE YY:Year Code WW: Week Code Product Type SERIES CODE Packing Options Part Number 30KPAxxxXX-HR Component Package Quantity Packaging Option P600 800 Tape & Reel Packaging Specification EIA STD RS-296 Tape and Reel Specification Off Center either side 2.063+0.079/-0.039 (53.0+2.0/-1.0) 0.028(0.7) 2.56 (65.0) 0.047 (1.2) 0.394+/-0.020 (10.0+/-0.5) 13.0 (330.2) 0.236 (6.0) Dimensions are in inches/mm 3.0 (76.2) 0.68 (17.27) 2.75 (69.85) Recess Depth Max. 0.75 (19.05) 30KPA-HR Series Direction of Feed 6 90 ©2015 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 03/06/15