PDF cURus UL 60950-1, CSA 60950-1

Issue Date:
2010-05-12
Page 1 of 7
Report Reference #
E135493-A1-UL
2012-02-17
UL TEST REPORT AND PROCEDURE
Standard:
Certification Type:
CCN:
Product:
Model:
UL 60950-1, 2nd Edition, 2007-03-27 (Information Technology
Equipment - Safety - Part 1: General Requirements)
CSA C22.2 No. 60950-1-07, 2nd Edition, 2007-03 (Information
Technology Equipment - Safety - Part 1: General Requirements)
Component Recognition
QQGQ2, QQGQ8 (Power Supplies for Information Technology
Equipment Including Electrical Business Equipment)
DC-DC Converter
HV BCM Series
HV BCM2 Series
Input: 230-400 Vdc
Output: 48 Vdc max, 375 W max
Rating:
See Enclosure Miscellaneous for model details.
Applicant Name and Address:
VICOR CORP
25 FRONTAGE RD
ANDOVER MA 01810
UNITED STATES
This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the
above referenced Standards. The products have been found to comply with the requirements covering the category and the products are
judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on
such products which comply with this Test Report and any other applicable requirements of UL LLC ('UL') in accordance with the FollowUp Service Agreement. Only those products which properly bear the UL Mark are considered as being covered by UL's Follow-Up
Service under the indicated Test Procedure.
The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety.
UL authorizes the applicant to reproduce the latest pages of the referenced Test Report consisting of the first page of the Specific
Technical Criteria through to the end of the Conditions of Acceptability.
Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL.
Prepared by:
Gerard Soprych
Reviewed by: David Keen
Copyright © 2012
Issue Date:
2010-05-12
Page 2 of 7
Report Reference #
E135493-A1-UL
2012-02-17
Supporting Documentation
The following documents located at the beginning of this Procedure supplement the requirements of this Test
Report:
A. Authorization - The Authorization page may include additional Factory Identification Code markings.
B. Generic Inspection Instructions i. Part AC details important information which may be applicable to products covered by this Procedure.
Products described in this Test Report must comply with any applicable items listed unless otherwise
stated in the body of this Test Report.
ii. Part AE details any requirements which may be applicable to all products covered by this Procedure.
Products described in this Test Report must comply with any applicable items listed unless otherwise
stated in the body of each Test Report.
iii. Part AF details the requirements for the UL Certification Mark which is not controlled by the technical
standard used to investigate these products. Products are permitted to bear only the Certification
Mark(s) corresponding to the countries for which it is certified, as indicated in each Test Report.
Product Description
The products described in this report are DC-DC Converters that provide an isolated intermediate bus
voltage.
Model Differences
See Enclosure Miscellaneous for model details.
Technical Considerations

Equipment mobility : for building-in

Connection to the mains : building-in

Operating condition : continuous

Access location : building-in

Over voltage category (OVC) : OVC II

Mains supply tolerance (%) or absolute mains supply values : N/A

Tested for IT power systems : No

IT testing, phase-phase voltage (V) : N/A

Class of equipment : Class II (double insulated)

Considered current rating (A) : -
Issue Date:
2010-05-12
Page 3 of 7
Report Reference #
E135493-A1-UL
2012-02-17

Pollution degree (PD) : PD 2

IP protection class : IP X0

Altitude of operation (m) : 2000

Altitude of test laboratory (m) : 150

Mass of equipment (kg) : 0.0125

Input Voltage: Nameplate rating is a nominal input voltage. The highest voltage BCM was evaluated
over the entire specified voltage range.
Engineering Conditions of Acceptability
For use only in or with complete equipment where the acceptability of the combination is determined by UL
LLC. When installed in an end-product, consideration must be given to the following:

The following components require special consideration during end-product Thermal (Heating) tests;
Keep the maximum semiconductor junction temperature 125°C or less. This can be achieved in one
of two ways. , Keep Tcasemax < 100C under all conditions where Tcasemax is the maximum case
temp of the VI Chip, or , Keep Tcasemax < 125C - (Pdissmax X 1.5) under all conditions , Pdissmax
is the maximum power dissipation of the module at temperature, defined by PInput_max POutput_max where POutput_max is defined as the maximum output power in the application.
Method three: Maintain the internal semiconductor junction trmperature at Tj = 125 degrees C or
less. This can be achieved by measuring the dc voltage at the TM (temperature monitor) lead and
converting the voltage to temperature. The TM has a nominal +27C set point of 3.0 Vdc and a
nominal gain of 10mV / degrees C. Example; TM = 3.4 Vdc, Tj = (27 + 40) 67 degrees C. ,

Fusing Requirements: To meet safety requirements, the input of the BCM module requires a
Bussmann PC-Tron fuse rated 2.5 A or less or an SOC type 36CFA rated 3.15A or less.

Input is intended to be supplied from a non-isolated offline circuit.

The output is considered to be SELV

Outputs above 240 Watts are considered to be at a hazardous energy level.

The output is separated from the input by reinforced insulation.
Issue Date:
2010-05-12
Page 4 of 7
Report Reference #
E135493-A1-UL
2012-02-17
VI Chip High Voltage BCM Model Number: Baaacdddeff Example: B384F120T24
B=B
BCM (Buss Converter Module)
B=
Constant
aaa = 384
Input Voltage
270
352
384
c= F
Package
Size
Full VIC
Nominal (range)
270 Vdc (240-330)
352 Vdc (330-365)
384 Vdc (360-400)
In Board
BGA
K
On Board
J-Lead
F
ddd = 120
Output Voltage Designator
110
11 Vdc
340
120
12 Vdc
440
125
12.5 Vdc
480
137
13.7 Vdc
e= T
Product Grade
-40 to 125C
T
-55 to 125C
M
ff = 24
Output Power Designator
24 240 W
35 350 W
30 300 W
37 375 W
33 330 W
Through Hole
T
34 Vdc
44 Vdc
48 Vdc
Issue Date:
2010-05-12
Page 5 of 7
Report Reference #
2012-02-17
Customer Special Model Numbers
Customer Special
Model Numbers
Equivalent Standard
Model Numbers
B352F110T30x
VIZ0002, VIZ0002x
VIZ0020, VIZ0020x
VIZ0048, VIZ0048x
VIZ0070, VIZ0070x
VIB0001TFJ, VIB0001TFJx
VIB0002TFJ, VIB0002TFJx
VIB0003TFJ, VIB0003TFJx
VIB0004TFJ, VIB0004TFJx
VMB0004MFJ, VMB0004MFJx
VIB0010TFJ, VIB0010TFJx
VIB0011TFJ, VIB0011TFJx
B352F110T30
B352F110T30
B352F440T37
B352F110T30
B352F440T37
B352F110T30
B384F480T33
B352F440T35
B270F340T24
B270F340M24
B352F125T33
B384F137T30
Special Model Options
VIB may be replaced by VMB for Military Designation
T may be replaced by M for Grade Designation
J may be replaced by T for Thru-Hole
x = revision, any letter A through Z, non-safety related
Example # 1: B384F120T30
BCM, 384 Vin, J Lead, 12 Vout, T Grade, 300W
Example # 2: B352F110T30
BCM, 352 Vin, J Lead, 11 Vout, T Grade, 300W
Example # 3: VIB0001TFJ
BCM, 352 Vin, J Lead, 11 Vout, T Grade, 300W
Example # 4: VMB0004MFT
BCM, 270 Vin, Thru-Hole, 34 Vout, M Grade, 240W
Example #5: VIZ0020
BCM, 352 Vin, J Lead, 44 Vout, T Grade, 375W
E135493-A1-UL
Issue Date:
2010-05-12
Page 6 of 7
Report Reference #
2012-02-17
VI Chip High Voltage BCM2 Model Number: BCMbbbcdddefffxzz
Example: BCM384F120T300A00
BCM = Constant
BCM Family (Buss Converter Module)
Standard version
BCM
Mil-COTS version
MBCM
bbb = 384
Input Voltage
270
352
384
Nominal (range)
270 Vdc (230-330)
352 Vdc (330-365)
384 Vdc (360-400)
c= F
Package Size and Lead Designator
Full VI Chip J-Lead
F
Full VI Chip Though-hole
T
ddd = 120
Output Voltage Designator (can be any three digits from 110 to 480)
Vout = (designator / 10), non-inclusive list of examples below
110
11 Vdc
338
33.8 Vdc
120
12 Vdc
340
34 Vdc
125
12.5 Vdc
450
45 Vdc
137
13.7 Vdc
480
48 Vdc
e= T
Product Grade
-40 to 125C
T
-55 to 125C
M
fff = 300
Output Power Designator (can be any three digits from 200 to 375)
non-inclusive list of examples below
200
200 W
300
300 W
235
235 W
330
330 W
240
240 W
350
350 W
270
270 W
375
375 W
E135493-A1-UL
Issue Date:
2010-05-12
Page 7 of 7
Report Reference #
2012-02-17
x= A
Revision (non-safety related)
x
Any alphanumeric character
zz = 00
Customer reference (non-safety related)
zz
Any alphanumeric character
Customer Special
Model Numbers
Equivalent Standard
Model Numbers
VIZ0089, VIZ0089x
BCM352F110T300A00
x = revision, any letter A through Z, non-safety related
E135493-A1-UL