Silicon Technology Reliability

Silicon Technology Reliability
Vishay Siliconix
VIS BCD PROCESS TECHNOLOGY 200901 to 201103
Sample Size
Equivalent Device Hours
Failure Rate in FIT
492
32 101 167
28.348
Failure Rate in FIT is calculated according to JEDEC standard JESD85, Methods for Calculating Failure Rates in Units of FITs,
based on accelerated high temperature operating life test results by using an apparent activation energy of 0.7 eV. The junction
temperature of the device at use is assumed to be 55 °C. A constant failure rate distribution is assumed. The upper confidence
bound of the failure rate is 60 %.
Document Number: 67870
Revision: 31-Mar-11
www.vishay.com
1
This document is subject to change without notice.
THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000