PBMN flush Main features Flush membrane Fully welded version Robust stainless steel housing External programming of zero High overpressure resistance Available with optional ATEX approval point and span with FlexProgrammer 9701 Applications Food Beverage Water treatment Chemical Measuring range -1 ... 0 bar up to 0 ... 400 bar Turn down 5:1 Long term stability ≤ ± 0.1% FS / Year Accuracy (20 °C) ≤ ± 0.5% FS, 0.25% FS, 0.1% FS Performance after Turn-Down [Turn-Down] * [Accuracy] FS (Linearity, hysteresis, repeatabillity, error of span and zero point) Technical specifications Measuring principle Piezoresistive silicon sensor Measuring ranges -1 ... 0 bar up to 0 ... 400 bar Type of pressure Relative / Absolute Turn down 5:1 Accuracy (20 °C) ≤ ± 0.5% FS, 0.25% FS, 0.1% FS Zero thermal drift ≤ ± 0.03% FS/10 K Span thermal drift ≤ ± 0.03% FS/10 K Long term stability ≤ ± 0.1% FS / Year Response time (10 … 90%) ≤ 5 ms (Linearity, hysteresis, repeatabillity, error of span and zero point) Process connections See page 3 Environment Temperature Storage -40 ... + 85°C Compensated range -40 ... + 85°C -40 ... +125°C Medium Protection rating IP65 (EN 60529) up to IP67 depending on electrical connection Vibration IEC60068-2-6 1.5 mm p-p (10 – 57 Hz), 10 g (58 Hz – 2 KHz) 10 cycles within 2.5 h per axis Shock IEC60068-2-27 50 g/11 ms 100 g/6 ms 10 x Imp. per axis and direction Bump IEC60068-2-27 100 g/2 ms 4000 x Imp. per axis and direction Random IEC60068-2-64 0.1 g2/Hz (20 Hz – 1 KHz) 30 min per axis (>10 g RMS) Electrical specification Output signal / Power supply Load impedance Current ouput Voltage output Insulation resistance 4 … 20 mA / 8 … 30 VDC 0…10 V / 13 … 30 VDC RΩ = (Usupply-8 V) / 20 mA > 5 KΩ >100 MΩ at 500 VDC Electrical connections See page 3 Material Design and specifications subject to change without notice Main characteristics Process connection SS 1.4404 AISI 316L or Hastelloy-C Housing SS 1.4404 AISI 316L Diaphragm SS 1.4435 AISI 316L or Hastelloy-C Sealing NBR, EPDM or FKM (Viton®) Cable PUR (without cooling neck) Medium -40 ... +200°C Ambient -40 ... + 85°C 2013-04-16 (with cooling neck) www.baumer.com Data sheet A11.35 Page 1 / 4 PBMN flush ATEX Approvals ATEX II 1G Ex ia IIC T4/T6 Ga All versions without cooling neck, DIN connector and with output signal code A1 ATEX II 1/2G Ex ia IIC T4/T6 Ga/Gb All versions without cooling neck, with DIN connector and output signal code A1 CE conformity EMC directive 2004/108/CE in accordance with EN61000-6-2, EN 61000-6-3 All versions with cooling neck, ATEX II 1G Ex ia IIC T3/T4/T6 Ga output signal code A1 and without DIN connector All versions with cooling neck, ATEX II 1/2G Ex ia IIC T3/T4/T6 DIN connector and output signal Ga/Gb code A1 ATEX II 1D Ex ia IIIC T107°C IP6X Da All versions with output signal code A1 Barrier data Ui ≤ 30 V Ii ≤ 100 mA Pi ≤ 750 mW Capacity Ci ≤ 31 nF CCable ≤ 0.12 nF/m Inductivity Li ≤ 3 μH LCable ≤ 1.1 μH/m Temperature class T1 ... T3: -40 <Tamb < 45/70/75/85 °C (ambient temperature) T1 ... T4: -40 <T < 85 °C amb T1 ... T6: -40 <Tamb < 70 °C Temperature class T1 ... T3: -40 <Tmed < 130/150/160/170/200 °C (medium temperature) T1 ... T4: -40 <T < 115/130 °C med T1 ... T6: -40 <Tmed < 75/80 °C For the application in Ex zone you have to respect the conditions mentioned in the ATEX Type Examination Certificate (SEV 11 ATEX 0129). You find the certificates and manuals under http://www.baumer.com/ Measuring ranges and overpressure safety Pressure in bar 0 ... 0.1 0 ... 0.16 0 ... 0.25 -0.1 ... 0.1 -0.2 ... 0.2 0 ... 0.4 0 ... 0.6 0 ... 1 -1 ... 0 -1 ... 0.6 0 ... 1.6 0 ... 2 0 ... 2.5 -1 ... 1.5 0 ... 4 -1 ... 3 -1 ... 5 0 ... 6 0 ... 10 -1 ... 9 0 ... 16 -1 ... 15 0 ... 20 0 ... 25 -1 ... 24 0 ... 40 -1 ... 39 0 ... 100 -1 ... 399 0 ... 400 1 3 15 60 70 135 400 690 Burst pressure 2 6 30 120 140 270 800 1350 2013-04-16 Over pressure Design and specifications subject to change without notice Pressure range www.baumer.com Data sheet A11.35 Page 2 / 4 PBMN flush Electrical connections Signal 4...20 at mA / Signal at 0...10 V Signal at 4...20 mA /atSignal 0...10V Connector DIN 43650 M12 4-pins 4 1 +VS / +VS 3 IOUT / GND n.c. / +VOUT 3 2 n.c. / +VOUT IOUT / GND 1 2 +VS / +VS n.c. / +VOUT earth earth Cable output Field housing (Red) / +VS / +VS Not included in delivery clamping range: 8...10 mm n.c. / +VOUT (Blue) / IOUT / GND 4 3 2 1 IOUT / GND (White) / n.c. / +VOUT +VS / +VS (Shield) / earth (Shield) / earth Dimensions (mm) Field Housing, Cable gland stainless steel, IP67 EN 175301-803A (DIN43650 A) 4 pins, IP65 ø8..10 Shielded cable (1,5 m), IP67 ø 6,3 Code 71 LCN = 77 mm G 1/2" Flush Cone (40°) (HEX 27) N/A LCN Code 44 51 9 20,5 ø 18 f7 G 1/2 B ø 30 G1 G 1/2" Flush O-Ring at the front (HEX 27) G 1" Flush O-Ring at the front (HEX 41) N/A Code 73 81 mm ø 25,5 G1 G 1" Flush Cone (40°, HEX 41) Code 74 89 mm 2013-04-16 Cooling Neck B 10 20,5 9 G 1/2" A Flush DIN3852 (HEX 27) ø 15,5 G 1/2 Code 43 43 39 39 A Code 54 Code 53 Code 46 22,3 2,5 16 33 Code 42 ø 22 Design and specifications subject to change without notice Code 44 ø 17,5 G 1/2 ø 22 27 Code 14 Code 41 ø 54,5 ø 22 ø 22 45,3 52 59,1 94 M12 4 pins, IP67 www.baumer.com Data sheet A11.35 Page 3 / 4 PBMN flush Ordering details PBMN flush PBMN Model Pressure transmitter . . x . xx . xx . xx . x . x . x . . 3 4 5 P > 250 mbar Only pressure type relative Only pressure type relative Only pressure type relative Only pressure type relative Only pressure type relative Only pressure type relative Only pressure type relative Only pressure type relative Only pressure type relative Only pressure type relative Only pressure type relative Only pressure type relative Only pressure type relative Only pressure type relative . B2H B4G B59 B72 B74 B76 B77 B79 B81 B82 B1L B08 B09 B10 B11 B12 B15 B16 B17 B18 B19 B20 B22 B24 B25 B26 B27 B31 B38 . R A . A1 A2 Output connection M12, 4 pins DIN 43650, 4 pins Shielded cable (1.5 m) Fiel housing . 14 44 53 54 Process connection G½" A flush DIN3852 G½" flush, cone G½" flush, o-ring at the front G1" flush, o-ring at the front G1" flush, cone G½" A flush DIN3852 with cooling neck G1" flush, o-ring at the front with cooling neck G1" flush, cone with cooling neck cooling neck P ≤ 40 bar P ≤ 40 bar P ≤ 40 bar P ≤ 40 bar Process connection material Stainless steel 1.4404 AISI 316L Hastelloy-C . 41 42 46 43 44 71 73 74 . 2 H Sealing NBR EPDM FKM (Viton®) www.baumer.com xxx . 1 2 3 T ≥ -10°C Design and specifications subject to change without notice 2 Output signal 4...20mA 0...10V Display Without ATEX Without ATEX according to SEV 11 ATEX 0129 Approval None Downscale Without downscale With downscale . – Kind of pressure Relative Absolute Oil filling Silicon oil FDA approved white oil x . 1 2 . 0 0 1 In combination with output signal code A1 0 S0x Data sheet A11.35 Page 4 / 4 2013-04-16 Pressure range and unit in bar -0.1...0.1 -0.2...0.2 -1...0 -1...0.6 -1...1.5 -1...3 -1...5 -1...9 -1...15 -1...24 -1...39 0...0.1 0...0.16 0...0.25 0...0.4 0...0.6 0...1 0...1.6 0...2 0...2.5 0...4 0...6 0...10 0...16 0...20 0...25 0...40 0...100 0...400 2 PBMN Housing material Stainless steel 1.4404 AISI 316L Accuracy 0.5% FS 0.25% FS 0.10% FS –