PBMN industrial Low Pressure Fully welded pressure transmitter for general industrial applications Main benefits Excellent accuracy and active temperature compensation for precise pressure measurements Universal field of applications due to fully welded and robust stainless steel housing External programming of zero point and span with FlexProgrammer 9701 Applications Pneumatic Water treatment Technical specifications Measuring principle Piezoresistive silicon sensor Measuring ranges -1 ... 0 bar up to 0 ... 40 bar Type of pressure Relative / Absolute Accuracy (20 °C) ≤ 0.5% FS ≤ 0.25% FS ≤ 0.1% FS Turn down 5:1 Performance after Turn down Zero thermal drift [Turn-Down] * [Accuracy] FS (includes linearity, hysteresis, repeatability, error of span and zero point according limit point adjustment) Chemical Factory automation Electrical specification Output signal / Power supply Load impedance Current ouput Voltage output Insulation resistance 4 … 20 mA / 8 … 30 VDC 0…10 V / 13 … 30 VDC RΩ = (Usupply-8 V) / 20 mA > 5 KΩ >100 MΩ at 500 VDC Electrical connections See page 3 Material Process connection SS 1.4404 AISI 316L ≤ ± 0.03% FS/10 K Housing SS 1.4404 AISI 316L Span thermal drift ≤ ± 0.03% FS/10 K Diaphragm SS 1.4435 AISI 316L Long term stability ≤ 0.1% FS / Year Sealing NBR or FKM (Viton®) Response time (10 … 90%) ≤ 5 ms Cable PUR Process connections See page 3 Environment -40 ... + 85°C -40 ... + 85°C -40 ... +120°C -40 ... + 85°C IP65 (EN 60529) up to IP67 depending on electrical connection Vibration IEC60068-2-6 1.5 mm p-p (10 – 57 Hz), 10 g (58 Hz – 2 KHz) 10 cycles within 2.5 h per axis Shock IEC60068-2-27 50 g/11 ms 100 g/6 ms 10 x Imp. per axis and direction Bump IEC60068-2-27 100 g/2 ms 4000 x Imp. per axis and direction Random IEC60068-2-64 0.1 g2/Hz (20 Hz – 1 KHz) 30 min per axis (>10 g RMS) 2014-06-27 Protection rating Design and specifications subject to change without notice Temperature Storage Compensated range Medium Ambient www.baumer.com Data sheet A11.37 Page 1 / 4 PBMN industrial Low Pressure Fully welded pressure transmitter for general industrial applications ATEX ATEX II 1G Ex ia IIC T4/T6 Ga Approvals All versions without DIN connector and with output signal code A1 CE conformity EMC directive 2004/108/CE in accordance with EN61000-6-2, EN 61000-6-3 ATEX II 1/2G All versions with DIN connector and output Ex ia IIC T4/T6 Ga/Gb signal code A1 ATEX II 1D Ex ia IIIC T107°C IP6X Da All versions with output signal code A1 Barrier data Ui ≤ 30 V Ii ≤ 100 mA Pi ≤ 750 mW Capacity Ci ≤ 31 nF CCable ≤ 0.12 nF/m Inductivity Li ≤ 3 μH LCable ≤ 1.1 μH/m Temperature class T1 ... T4: -40 <Tamb < 85 °C (ambient temperature) T1 ... T6: -40 <T < 70 °C amb Temperature class T1 ... T4: -40 <Tmed < 115 °C (medium temperature) T1 ... T6: -40 <T < 75 °C med For the application in Ex zone you have to respect the conditions mentioned in the ATEX Type Examination Certificate (SEV 11 ATEX 0129). You find the certificates and manuals under http://www.baumer.com/ Measuring ranges and overpressure safety Pressure in bar Pressure range 0 ... 0.1 0 ... 0.16 0 ... 0.25 -0.1 ... 0.1 -0.2 ... 0.2 0 ... 0.4 0 ... 0.6 0 ... 1 -1 ... 0 -1 ... 0.6 0 ... 1.6 0 ... 2 0 ... 2.5 -1 ... 1.5 0 ... 4 -1 ... 3 -1 ... 5 0 ... 6 0 ... 10 -1 ... 9 0 ... 16 -1 ... 15 0 ... 20 0 ... 25 -1 ... 24 0 ... 40 -1 ... 39 1 3 15 60 70 135 Burst pressure 2 6 30 120 140 270 2014-06-27 Design and specifications subject to change without notice Over pressure www.baumer.com Data sheet A11.37 Page 2 / 4 PBMN industrial Low Pressure Fully welded pressure transmitter for general industrial applications Electrical connections Signal 4...20 at mA / Signal at 0...10 V Signal at 4...20 mA /atSignal 0...10V Connector DIN 43650 M12 4-pins +VS / +VS 3 IOUT / GND n.c. / +VOUT 4 1 3 2 n.c. / +VOUT IOUT / GND +VS / +VS 1 2 n.c. / +VOUT earth earth Cable output Field housing (Red) / +VS / +VS Not included in delivery clamping range: 8...10 mm n.c. / +VOUT (Blue) / IOUT / GND 4 3 2 1 IOUT / GND (White) / n.c. / +VOUT +VS / +VS (Shield) / earth (Shield) / earth Dimensions (mm) EN 175301-803A (DIN 43650 A) 4 pins, IP65 Fieldhousing, Cable Gland stainless steel IP67 Ø 8...10 Shielded cable (1,5 m), IP67 Ø 6,3 G1/2" EN 837 (HEX 23) Ø 18,8 Ø 26,9 3 24,5 3 24,5 G 1/2 G 1/4 Ø 10 Ø 25 G 1/2 Ø 26,9 1/4" NPT (HEX 23) 1/2" NPT (HEX 23) G1/4" DIN 3852-E (HEX 23) G1/2" DIN 3852-E (HEX 27) G1/2" DIN 3852 open (HEX 27) G1/4" female (HEX 27) 2014-06-27 G1/4" EN 837 (HEX 23) G 1/4 Code 12 Design and specifications subject to change without notice G 1/2 Code 19 Code 09 14 22,5 1/2-14 NPT 1/4-18 NPT Ø 6 12 3 25,5 18 20,5 G 1/4 13 30,5 23 3 22,5 15 2 Ø 5 Code 06 Code 05 Code 04 Code 03 Code 54 Code 53 14 Code 44 Code 14 Ø 22 Ø 22 Ø 22 Ø 22 Code 02 Ø 54,5 14,5 11 61 71,5 105 M12 4 pins, IP67 www.baumer.com Data sheet A11.37 Page 3 / 4 PBMN industrial Low Pressure Fully welded pressure transmitter for general industrial applications Ordering details PBMN industrial LP PBMN Model Pressure transmitter . . xxx . x . xx . xx . xx . x . x . x . – 2 . P > 250 mbar Only pressure type relative Only pressure type relative Only pressure type relative Only pressure type relative Only pressure type relative Only pressure type relative Only pressure type relative Only pressure type relative Only pressure type relative Only pressure type relative Only pressure type relative Only pressure type relative Only pressure type relative Only pressure type relative Kind of pressure Relative Absolute 3 4 5 . B2H B4G B59 B72 B74 B76 B77 B79 B81 B82 B1L B08 B09 B10 B11 B12 B15 B16 B18 B19 B20 B22 B24 B25 B26 B27 . R A Output signal 4...20mA 0...10V . A1 A2 Output connection M12, 4 pins DIN 43650, 4 pins Shielded cable (1.5 m) Fiel housing . 14 44 53 54 Process connection G¼ EN 837 G½ EN 837 ¼ NPT ½ NPT G¼ DIN 3852 G½ DIN 3852 G¼ female G½ DIN 3852 open connection (10 mm) Process connection material Stainless steel 1.4404 AISI 316L . 02 03 04 05 06 09 12 19 . 2 Sealing Without NBR FKM (Viton®) In combination with process connection code 06/09 In combination with process connection code 06/09 Oil filling Silicon oil FDA approved white oil T ≥ -10°C . 0 1 3 . 1 2 . 0 0 1 In combination with output signal code A1 0 S0x 2014-06-27 Display Without ATEX Without ATEX according to SEV 11 ATEX 0129 Approval None Downscale Without downscale With downscale x Design and specifications subject to change without notice Pressure range and unit in bar -0.1...0.1 -0.2...0.2 -1...0 -1...0.6 -1...1.5 -1...3 -1...5 -1...9 -1...15 -1...24 -1...39 0...0.1 0...0.16 0...0.25 0...0.4 0...0.6 0...1 0...1.6 0...2.5 0...4 0...6 0...10 0...16 0...20 0...25 0...40 2 PBMN Housing material Stainless steel 1.4404 AISI 316L Accuracy 0.5% FS 0.25% FS 0.10% FS – www.baumer.com Data sheet A11.37 Page 4 / 4