Technical specifications
Measuring principle Piezoresistive silicon sensor
Measuring ranges
-1 ... 0 bar up to 0 ... 40 bar
Type of pressure
Relative / Absolute
Accuracy (20 °C)
≤ 0.5% FS
≤ 0.25% FS
≤ 0.1% FS
Turn down
5:1
Performance after
Turn down
Zero thermal drift
[Turn-Down] * [Accuracy] FS
(includes linearity, hysteresis,
repeatability, error of span
and zero point according limit
point adjustment)
„„Chemical
„„Factory automation
Electrical specification
Output signal /
Power supply
Load impedance
Current ouput
Voltage output
Insulation resistance
4 … 20 mA / 8 … 30 VDC
0…10 V / 13 … 30 VDC
RΩ = (Usupply-8 V) / 20 mA
> 5 KΩ
>100 MΩ at 500 VDC
Electrical connections See page 3
Material
Process connection SS 1.4404 AISI 316L
≤ ± 0.03% FS/10 K
Housing
SS 1.4404 AISI 316L
Span thermal drift
≤ ± 0.03% FS/10 K
Diaphragm
SS 1.4435 AISI 316L
Long term stability
≤ 0.1% FS / Year
Sealing
NBR or FKM (Viton®)
Response time
(10 … 90%)
≤ 5 ms
Cable
PUR
Process connections See page 3
Environment
-40 ... + 85°C
-40 ... + 85°C
-40 ... +120°C
-40 ... + 85°C
IP65 (EN 60529) up to IP67 depending on
electrical connection
Vibration
IEC60068-2-6
1.5 mm p-p (10 – 57 Hz), 10 g (58 Hz – 2 KHz)
10 cycles within 2.5 h per axis
Shock
IEC60068-2-27
50 g/11 ms 100 g/6 ms
10 x Imp. per axis and direction
Bump
IEC60068-2-27
100 g/2 ms
4000 x Imp. per axis and direction
Random
IEC60068-2-64
0.1 g2/Hz (20 Hz – 1 KHz)
30 min per axis (>10 g RMS)
2014-06-27
Protection rating
Design and specifications subject to change without notice
Temperature
Storage
Compensated range
Medium
Ambient
www.baumer.com
Data sheet A11.37
Page 1 / 4
PBMN industrial Low Pressure
Fully welded pressure transmitter for general
industrial applications
ATEX
ATEX II 1G
Ex ia IIC T4/T6 Ga
Approvals
All versions without DIN connector and with
output signal code A1
CE conformity
EMC directive 2004/108/CE in accordance with
EN61000-6-2, EN 61000-6-3
ATEX II 1/2G
All versions with DIN connector and output
Ex ia IIC T4/T6 Ga/Gb signal code A1
ATEX II 1D
Ex ia IIIC T107°C
IP6X Da
All versions with output signal code A1
Barrier data
Ui ≤ 30 V
Ii ≤ 100 mA
Pi ≤ 750 mW
Capacity
Ci ≤ 31 nF
CCable ≤ 0.12 nF/m
Inductivity
Li ≤ 3 μH
LCable ≤ 1.1 μH/m
Temperature class T1 ... T4: -40 <Tamb < 85 °C
(ambient temperature) T1 ... T6: -40 <T < 70 °C
amb
Temperature class T1 ... T4: -40 <Tmed < 115 °C
(medium temperature) T1 ... T6: -40 <T < 75 °C
med
For the application in Ex zone you have to respect the conditions
mentioned in the ATEX Type Examination Certificate (SEV 11 ATEX
0129).
You find the certificates and manuals under http://www.baumer.com/
Measuring ranges and overpressure safety
Pressure in bar
Pressure range
0 ... 0.1
0 ... 0.16
0 ... 0.25
-0.1 ... 0.1
-0.2 ... 0.2
0 ... 0.4
0 ... 0.6
0 ... 1
-1 ... 0
-1 ... 0.6
0 ... 1.6
0 ... 2
0 ... 2.5
-1 ... 1.5
0 ... 4
-1 ... 3
-1 ... 5
0 ... 6
0 ... 10
-1 ... 9
0 ... 16
-1 ... 15
0 ... 20
0 ... 25
-1 ... 24
0 ... 40
-1 ... 39
1
3
15
60
70
135
Burst pressure
2
6
30
120
140
270
2014-06-27
Design and specifications subject to change without notice
Over pressure
www.baumer.com
Data sheet A11.37
Page 2 / 4
PBMN industrial Low Pressure
Fully welded pressure transmitter for general
industrial applications
Electrical connections
Signal
4...20 at
mA
/ Signal at 0...10 V
Signal at 4...20
mA /atSignal
0...10V
Connector
DIN 43650
M12
4-pins
+VS / +VS
3
IOUT / GND
n.c. / +VOUT
4
1
3
2
n.c. / +VOUT
IOUT / GND
+VS / +VS
1
2
n.c. / +VOUT
earth
earth
Cable
output
Field housing
(Red) / +VS / +VS
Not included in delivery
clamping range: 8...10 mm
n.c. / +VOUT
(Blue) / IOUT / GND
4
3
2
1
IOUT / GND
(White) / n.c. / +VOUT
+VS / +VS
(Shield) / earth
(Shield) / earth
Dimensions (mm)
EN 175301-803A
(DIN 43650 A)
4 pins, IP65
Fieldhousing,
Cable Gland
stainless steel IP67
Ø 8...10
Shielded cable
(1,5 m),
IP67
Ø 6,3
G1/2" EN 837
(HEX 23)
Ø 18,8
Ø 26,9
3
24,5
3
24,5
G 1/2
G 1/4
Ø 10
Ø 25
G 1/2
Ø 26,9
1/4" NPT
(HEX 23)
1/2" NPT
(HEX 23)
G1/4"
DIN 3852-E
(HEX 23)
G1/2"
DIN 3852-E
(HEX 27)
G1/2"
DIN 3852
open
(HEX 27)
G1/4"
female
(HEX 27)
2014-06-27
G1/4" EN 837
(HEX 23)
G 1/4
Code 12
Design and specifications subject to change without notice
G 1/2
Code 19
Code 09
14
22,5
1/2-14 NPT
1/4-18 NPT
Ø 6
12 3
25,5
18
20,5
G 1/4
13
30,5
23
3
22,5
15
2
Ø 5
Code 06
Code 05
Code 04
Code 03
Code 54
Code 53
14
Code 44
Code 14
Ø 22
Ø 22
Ø 22
Ø 22
Code 02
Ø 54,5
14,5
11
61
71,5
105
M12
4 pins, IP67
www.baumer.com
Data sheet A11.37
Page 3 / 4
PBMN industrial Low Pressure
Fully welded pressure transmitter for general
industrial applications
Ordering details PBMN industrial LP
PBMN
Model
Pressure transmitter
.
.
xxx
.
x
.
xx
.
xx
.
xx
.
x
.
x
.
x
.
–
2
.
P > 250 mbar
Only pressure type relative
Only pressure type relative
Only pressure type relative
Only pressure type relative
Only pressure type relative
Only pressure type relative
Only pressure type relative
Only pressure type relative
Only pressure type relative
Only pressure type relative
Only pressure type relative
Only pressure type relative
Only pressure type relative
Only pressure type relative
Kind of pressure
Relative
Absolute
3
4
5
.
B2H
B4G
B59
B72
B74
B76
B77
B79
B81
B82
B1L
B08
B09
B10
B11
B12
B15
B16
B18
B19
B20
B22
B24
B25
B26
B27
.
R
A
Output signal
4...20mA
0...10V
.
A1
A2
Output connection
M12, 4 pins
DIN 43650, 4 pins
Shielded cable (1.5 m)
Fiel housing
.
14
44
53
54
Process connection
G¼ EN 837
G½ EN 837
¼ NPT
½ NPT
G¼ DIN 3852
G½ DIN 3852
G¼ female
G½ DIN 3852 open connection (10 mm)
Process connection material
Stainless steel 1.4404 AISI 316L
.
02
03
04
05
06
09
12
19
.
2
Sealing
Without
NBR
FKM (Viton®)
In combination with process connection code 06/09
In combination with process connection code 06/09
Oil filling
Silicon oil
FDA approved white oil
T ≥ -10°C
.
0
1
3
.
1
2
.
0
0
1
In combination with output signal code A1
0
S0x
2014-06-27
Display
Without
ATEX
Without
ATEX according to SEV 11 ATEX 0129
Approval
None
Downscale
Without downscale
With downscale
x
Design and specifications subject to change without notice
Pressure range and unit in bar
-0.1...0.1
-0.2...0.2
-1...0
-1...0.6
-1...1.5
-1...3
-1...5
-1...9
-1...15
-1...24
-1...39
0...0.1
0...0.16
0...0.25
0...0.4
0...0.6
0...1
0...1.6
0...2.5
0...4
0...6
0...10
0...16
0...20
0...25
0...40
2
PBMN
Housing material
Stainless steel 1.4404 AISI 316L
Accuracy
0.5% FS
0.25% FS
0.10% FS
–
www.baumer.com
Data sheet A11.37
Page 4 / 4