Y91

Y91
pressure transmitter
Main features
„„
Robust stainless steel housing
„„
Intrinsically safe version (LCIE 02 ATEX 6133X)
„„
Available with optional Marine approval (Bureau Veritas Marine)
Applications
„„Chemical
„„Pneumatic
„„Energy
Measuring range
-1 ... 0 bar up to 0 ... 600 bar
Long term stability
0.2% FS / Year
Accuracy (20 °C)
≤ ± 0.3% FS (BFSL)
(linearity, hysteresis and
repeatability according Best
Fit Straight Line)
Technical specifications
Measuring principle Thick film on ceramic
Measuring ranges
-1 ... 0 bar up to 0 ... 600 bar
Type of pressure
Relative / Absolute
Accuracy (20 °C)
(linearity, hysteresis and
repeatability according Best
Fit Straight Line)
≤ ± 0.3% FS (BFSL)
≤ ± 0.6% FS (BFSL) for P ≤ 60 mbar and
P= 600 bar
Error of zero point
≤ ± 1% FS
Error of span
≤ ± 1% FS
Zero thermal drift
≤ ± 0.25% FS/10 K (P > 1 bar)
≤ ± 0.60% FS/10 K (P ≤ 1 bar)
Span thermal drift
≤ ± 0.15% FS/10 K (P > 1 bar)
≤ ± 0.15% FS/10 K (P ≤ 1 bar)
Long term stability
0.2% FS / Year
Response time
(10 … 90%)
≤ 3 ms
Electrical specification
Output signal /
Power supply
Load impedance
Current ouput
Voltage output
4 … 20 mA / 11 … 28 VDC
0…10 V / 14 … 28 VDC
RΩ = (Usupply-11 V) / 20 mA
> 2.5 KΩ
Insulation resistance >100 MΩ at 500 VDC
Electrical connections See page 3
Material
Process connection SS 1.4404 AISI 316L
and housing
Ceramic (96% Al2O3)
Diaphragm
Sealing
NBR, EPDM, CR, FFKM or FKM (Viton®)
Cable
PVC
Design and specifications subject to change without notice
Main characteristics
„„Shipbuilding
„„Industrial gas
Process connections See page 3
Environment
-40 ... + 85°C
-10 ... + 55°C
-25 ... +100°C
-25 ... + 70°C
Protection rating
IP65 (EN 60529) up to IP67 depending on
electrical connection
Vibration
IEC60068-2-6
Shock
IEC60068-2-27
1.5 mm p-p (10 – 55 Hz), 20 g (55 Hz – 2 KHz)
www.baumer.com
25 falls from 1 m on concrete ground
2013-09-04
Temperature
Storage
Compensated range
Medium
Ambient
Data sheet A11.11
Page 1 / 4
Y91
pressure transmitter
ATEX
Approvals
EMC directive 2004/108/CE in accordance with
EN 61000-6-2, EN 61000-6-3, EN 61326-1
(Tab.2)
Pressure directive 97/23/CE
CE conformity
I M1
Ex ia I Ma
II 1 G D
Ex ia IIC T6 or T5 Ga
II 1 G D
Ex ia IIIC T80°C or T95°C Da IP6X
Barrier data
Ui ≤ 28 V
Ii ≤ 120 mA
Pi ≤ 800 mW
Capacity
(current output)
Ci ≤ 30 nF
Capacity
(voltage output)
Ci ≤ 60 nF
Ambient temperature Ta
G: T6
G: T5
Ta = +40°C
Ta = +70°C
D IP65: Surface temperature = +80°C
D IP65: Surface temperature = +95°C
(G = Gas, D = Dust)
For the application in Ex zone you have to respect the conditions
mentioned in the ATEX Type Examination Certificate (LCIE 02 ATEX
6133X).
You find the certificates and manuals under http://www.baumer.com/
Measuring ranges and overpressure safety
Pressure in mbar
Pressure
range
0 ... 25
0 ... 40
0 ... 60
0 ... 100
0 ... 160
0 ... 250
0 ... 400
0 ... 600
Over pressure
110
275
500
1000
Burst pressure
200
500
1000
2000
Pressure in bar
Pressure
range
-1 ... 0
-1 ... 0.6
0 ... 1
0 ... 1.6
-1 ... 1.5
0 ... 2.5
-1 ... 3
0 ... 4
-1 ... 5
0 ... 6
-1 ... 15
0 ... 16
-1 ... 24
0 ... 25
-1 ... 39
0 ... 40
Over pressure
3
4
8
12
32
50
80
Burst pressure
6
7
12
18
48
75
120
Pressure in bar
0 ... 60
0 ... 100
0 ... 160
0 ... 250
0 ... 400
0 ... 600
120
200
320
500
600
800
Burst pressure
180
300
480
600
800
1000
2013-09-04
Over pressure
Design and specifications subject to change without notice
Pressure
range
www.baumer.com
Data sheet A11.11
Page 2 / 4
Y91
pressure transmitter
Dimensions (mm)
Standard version for P ≥ 1 bar
DIN 43650 plug
IP 65
Pig tail (length 1.5 m)
IP 65
Standard version for P < 1 bar
DIN 43650 plug
IP 65
Access to adjustments
96
Connections
Y913
+A : White
- A : Blue
: Ground
Connections
Y912
1 : +A
2 :-A
3 :
: Ground
kg
0.300
1 : +M
2 :-A/-M
3 : +A
: Ground
+M
: Yellow
- A / - M : Blue
+A
: Red
: Ground
kg
0.350 [0.450]
kg
0.400
Version also used for -1...0 bar and 0...1 bar ranges with ±50%
span adjustment option.
Terminal strip outlet + screwed cap
IP 67
M12, 4 contacts plug
IP 65
Optional accessory
Ø 38
Ø6 ... Ø8
Connections
Connections
Y912
1 : +A
2 :-A
3 :
: Ground
1 : +M
2 :-A/-M
3 : +A
: Ground
85 [106]
Design and specifications subject to change without notice
10
5
: Plug
: Case
: Seal
: Connector
: Nut
: PG7 Cable gland (horizontal or vertical)
1 : +A
2:
3 : Ground
4:-A
Y912
1 : +A
2 : +M
3 : Ground
4:-A/-M
10
61 [82]
3
1
2
3
4
5
6
2
Y913
6
2
4
3
1
72 [93]
107 [128]
1
4
43
Y913
kg
0.300 [0.400]
27
kg
27
2013-09-04
0.400 [0.500]
www.baumer.com
Data sheet A11.11
Page 3 / 4
Y91
pressure transmitter
Ordering details Y91
Y91 – x .
Y91
Output signal
0...10 V
4...20 mA
Sealing
NBR
CR
EPDM
FFKM (Chemraz® 505)
FKM (Viton®)
Pressure range and unit in bar
0...0.025
0...0.04
0...0.06
0...0.1
0...0.16
0...0.25
0...0.4
0...0.6
0...-1
-1...0.6
-1...1.5
-1...3
-1...5
-1...9
-1...15
-1...24
-1...39
0...1
0...1.6
0...2.5
0...4
0...6
0...10
0...16
0...25
0...40
0...100
0...160
0...250
0...400
0...600
1 bar ≤ P < 250 mbar
Only pressure type relative
Only pressure type relative
Only pressure type relative
Only pressure type relative
Only pressure type relative
Only pressure type relative
Only pressure type relative
Only pressure type relative
Only pressure type relative
Only pressure type relative
Only pressure type relative
Only pressure type relative
Only pressure type relative
Only pressure type relative
Only pressure type relative
Only pressure type relative
Only pressure type relative
x
.
xxx
.
x
/
xxxx
.
2
3
5
6
9
P ≥ 250 mbar
1 bar ≤ P < 250 mbar
.
–
2
3
Process connection
G¼ EN 837
G½ EN 837
¼ NPT
½ NPT
M20x150
x
.
3
4
5
7
9
.
N05
N06
N07
N08
N09
N10
N11
N12
B59
B72
B74
B76
B77
B79
B81
B82
B1L
B15
B16
B18
B19
B20
B22
B24
B26
B27
B31
B33
B35
B38
B39
Kind of pressure
Relative
Absolute
.
R
A
Output connection
DIN 43650, 4 pins
Shielded cable (1.5 m)
M12, 4 pins
Terminal strip outlet + screwed cap
Terminal strip outlet + cap with M20x150 thread and gland
/
2013-09-04
2160
2164
2166
2167
Design and specifications subject to change without notice
Model
Pressure transmitter
www.baumer.com
Data sheet A11.11
Page 4 / 4