PBMN industrial High Pressure Main features Fully welded version Robust stainless steel housing External programming of zero point and span with FlexProgrammer 9701 High overpressure resistance Available with optional ATEX approval Applications Hydraulic Oxygen application Measuring range 0 ... 60 bar up to 0 ... 1600 bar Turn down 5:1 Long term stability ≤ ± 0.1% FS / Year Accuracy (20 °C) ≤ ± 0.5% FS, 0.25% FS, 0.1% FS Performance after Turn-Down [Turn-Down] * [Accuracy] FS (Linearity, hysteresis, repeatabillity, error of span and zero point) Technical specifications Measuring principle Resistive thin film Measuring ranges 0 ... 60 bar up to 0 ... 1600 bar Type of pressure Relative Turn down 5:1 Accuracy (20 °C) ≤ ± 0.5% FS, 0.25% FS, 0.1% FS Zero thermal drift ≤ ± 0.03% FS/10 K Span thermal drift ≤ ± 0.03% FS/10 K Long term stability ≤ ± 0.1% FS / Year Response time (10 … 90%) ≤ 5 ms (Linearity, hysteresis, repeatabillity, error of span and zero point) Process connections See page 3 Environment -40 ... + 85°C -40 ... + 85°C -40 ... +120°C -40 ... + 85°C IP65 (EN 60529) up to IP67 depending on electrical connection Vibration IEC60068-2-6 1.5 mm p-p (10 – 57 Hz), 10 g (58 Hz – 2 KHz) 10 cycles within 2.5 h per axis Shock IEC60068-2-27 50 g/11 ms 100 g/6 ms 10 x Imp. per axis and direction Bump IEC60068-2-27 100 g/2 ms 4000 x Imp. per axis and direction Random IEC60068-2-64 0.1 g2/Hz (20 Hz – 1 KHz) 30 min per axis (>10 g RMS) Electrical specification Output signal / Power supply Load impedance Current ouput Voltage output Insulation resistance 4 … 20 mA / 8 … 30 VDC 0…10 V / 13 … 30 VDC RΩ = (Usupply-8 V) / 20 mA > 5 KΩ >100 MΩ at 500 VDC Electrical connections See page 3 Material Process connection SS 1.4301 AISI 304 Housing SS 1.4404 AISI 316L Diaphragm SS 1.4542 AISI 630 Sealing NBR or FKM (Viton®) Cable PUR Surface cleanliness for oxygen application Pieces in contact with ≤ 220 mg/m2 the medium free of oil and grease 2013-04-10 Temperature Storage Compensated range Medium Ambient Protection rating Design and specifications subject to change without notice Main characteristics www.baumer.com Data sheet A11.38 Page 1 / 4 PBMN industrial High Pressure ATEX Approvals ATEX II 1G Ex ia IIC T4/T6 Ga All versions without DIN connector and with output signal code A1 ATEX II 1/2G Ex ia IIC T4/T6 Ga/Gb All versions with DIN connector and output signal code A1 ATEX II 1D Ex ia IIIC T107°C IP6X Da All versions with output signal code A1 Barrier data Ui ≤ 30 V Ii ≤ 100 mA Pi ≤ 750 mW Capacity Ci ≤ 31 nF CCable ≤ 0.12 nF/m Inductivity Li ≤ 3 μH LCable ≤ 1.1 μH/m CE conformity EMC directive 2004/108/CE in accordance with EN61000-6-2, EN 61000-6-3 Temperature class T1 ... T4: -40 <Tamb < 85 °C (ambient temperature) T1 ... T6: -40 <T < 70 °C amb Temperature class T1 ... T4: -40 <Tmed < 115 °C (medium temperature) T1 ... T6: -40 <T < 75 °C med For the application in Ex zone you have to respect the conditions mentioned in the ATEX Type Examination Certificate (SEV 11 ATEX 0129). You find the certificates and manuals under http://www.baumer.com/ Measuring ranges and overpressure safety Pressure in bar Pressure range 0 ... 60 0 ... 100 0 ... 160 0 ... 250 0 ... 400 0 ... 600 Over pressure 120 200 320 500 800 1200 2000 3200 Burst pressure 480 800 1280 2000 3200 4000 4000 4000 0 ... 1600 2013-04-10 Design and specifications subject to change without notice 0 ... 1000 www.baumer.com Data sheet A11.38 Page 2 / 4 PBMN industrial High Pressure Electrical connections Signal 4...20 at mA / Signal at 0...10 V Signal at 4...20 mA /atSignal 0...10V Connector DIN 43650 M12 4-pins +VS / +VS 3 IOUT / GND n.c. / +VOUT 4 1 3 2 n.c. / +VOUT IOUT / GND +VS / +VS 1 2 n.c. / +VOUT earth earth Cable output Field housing (Red) / +VS / +VS Not included in delivery clamping range: 8...10 mm n.c. / +VOUT (Blue) / IOUT / GND 4 3 2 1 IOUT / GND (White) / n.c. / +VOUT +VS / +VS (Shield) / earth (Shield) / earth Dimensions (mm) EN 175301-803A (DIN 43650 A) 4 pins, IP65 Shielded cable (1,5 m), IP67 Ø 6,3 61 71,5 M12 4 pins, IP67 Code 44 1/2-14 NPT 1/4-18 NPT G 1/2 G 1/4 Code 12 14,5 11 3 24,5 Code 09 14 36 22,5 12 3 25,5 18 13 20,5 Ø6 Code 08 Code 06 G 1/4 G 1/2 Ø 18,8 M14 x 1,5 Ø 25 Ø 26,9 Ø 22,9 G1/2" EN 837 (HEX 23) 1/4" NPT (HEX 23) 1/2" NPT (HEX 23) G1/4" DIN 3852 (HEX 23) M14x1.5 cone 60° (HEX 23) G1/2" DIN 3852 (HEX 27) G1/4" female (HEX 27) 2013-04-10 G1/4" EN 837 (HEX 23) Design and specifications subject to change without notice G 1/4 3 30,5 Ø5 Code 05 23 15 2 22,5 Code 04 Code 03 Code 53 26,5 Code 14 Code 02 Ø 22 Ø 22 Ø 22 www.baumer.com Data sheet A11.38 Page 3 / 4 PBMN industrial High Pressure Ordering details PBMN industrial HP PBMN Model Pressure transmitter – 2 . xxx . x . xx . xx . xx . x . x . x . – . 3 4 5 Pressure range and unit in bar 0...60 0...100 0...160 0...250 0...400 0...600 0...1000 0...1600 . B29 B31 B33 B35 B38 B39 B41 B42 Kind of pressure Relative . R Output signal 4...20mA 0...10V . A1 A2 Output connection M12, 4 pins DIN 43650, 4 pins Shielded cable (1.5 m) . 14 44 53 P ≤ 1000 bar P ≤ 1000 bar P ≤ 1000 bar P ≤ 1000 bar P ≤ 600 bar P ≥ 1000 bar P ≤ 600 bar P ≤ 1000 bar Process connection material Stainless steel 1.4301 AISI 304 . 02 03 04 05 06 08 09 12 . 4 In combination with process connection code 06/09 In combination with process connection code 06/09 Oil filling Without . 0 1 3 . 0 Display Without ATEX Without ATEX according to SEV 11 ATEX 0129 In combination with output signal code A1 Approval None Free of oil and grease (pieces in contact with the medium) Downscale Without downscale With downscale . 0 0 1 0 6 2013-04-10 S0x Design and specifications subject to change without notice 2 Accuracy 0.5% FS 0.25% FS 0.10% FS Sealing Without NBR FKM (Viton®) . PBMN Housing material Stainless steel 1.4404 AISI 316L Process connection G¼ EN 837 G½ EN 837 ¼ NPT ½ NPT G¼ DIN 3852 M14x1.5 cone 60° G½ DIN 3852 G¼ female x www.baumer.com Data sheet A11.38 Page 4 / 4