Technical Data High Pressure

PBMN
industrial High Pressure
Main features
„„
Fully welded version
„„
Robust stainless steel housing
„„
External programming of zero
point and span with FlexProgrammer 9701
„„High overpressure resistance
„„
Available with optional ATEX
approval
Applications
„„Hydraulic
„„Oxygen application
Measuring range
0 ... 60 bar up to 0 ... 1600 bar
Turn down
5:1
Long term stability
≤ ± 0.1% FS / Year
Accuracy (20 °C)
≤ ± 0.5% FS, 0.25% FS, 0.1% FS
Performance after
Turn-Down
[Turn-Down] * [Accuracy] FS
(Linearity, hysteresis, repeatabillity, error of span and
zero point)
Technical specifications
Measuring principle Resistive thin film
Measuring ranges
0 ... 60 bar up to 0 ... 1600 bar
Type of pressure
Relative
Turn down
5:1
Accuracy (20 °C)
≤ ± 0.5% FS, 0.25% FS, 0.1% FS
Zero thermal drift
≤ ± 0.03% FS/10 K
Span thermal drift
≤ ± 0.03% FS/10 K
Long term stability
≤ ± 0.1% FS / Year
Response time
(10 … 90%)
≤ 5 ms
(Linearity, hysteresis, repeatabillity, error of span and
zero point)
Process connections See page 3
Environment
-40 ... + 85°C
-40 ... + 85°C
-40 ... +120°C
-40 ... + 85°C
IP65 (EN 60529) up to IP67 depending on
electrical connection
Vibration
IEC60068-2-6
1.5 mm p-p (10 – 57 Hz), 10 g (58 Hz – 2 KHz)
10 cycles within 2.5 h per axis
Shock
IEC60068-2-27
50 g/11 ms 100 g/6 ms
10 x Imp. per axis and direction
Bump
IEC60068-2-27
100 g/2 ms
4000 x Imp. per axis and direction
Random
IEC60068-2-64
0.1 g2/Hz (20 Hz – 1 KHz)
30 min per axis (>10 g RMS)
Electrical specification
Output signal /
Power supply
Load impedance
Current ouput
Voltage output
Insulation resistance
4 … 20 mA / 8 … 30 VDC
0…10 V / 13 … 30 VDC
RΩ = (Usupply-8 V) / 20 mA
> 5 KΩ
>100 MΩ at 500 VDC
Electrical connections See page 3
Material
Process connection SS 1.4301 AISI 304
Housing
SS 1.4404 AISI 316L
Diaphragm
SS 1.4542 AISI 630
Sealing
NBR or FKM (Viton®)
Cable
PUR
Surface cleanliness for oxygen application
Pieces in contact with ≤ 220 mg/m2
the medium free of oil
and grease
2013-04-10
Temperature
Storage
Compensated range
Medium
Ambient
Protection rating
Design and specifications subject to change without notice
Main characteristics
www.baumer.com
Data sheet A11.38
Page 1 / 4
PBMN
industrial High Pressure
ATEX
Approvals
ATEX II 1G
Ex ia IIC T4/T6 Ga
All versions without DIN connector and with
output signal code A1
ATEX II 1/2G
Ex ia IIC T4/T6
Ga/Gb
All versions with DIN connector and output
signal code A1
ATEX II 1D
Ex ia IIIC T107°C
IP6X Da
All versions with output signal code A1
Barrier data
Ui ≤ 30 V
Ii ≤ 100 mA
Pi ≤ 750 mW
Capacity
Ci ≤ 31 nF
CCable ≤ 0.12 nF/m
Inductivity
Li ≤ 3 μH
LCable ≤ 1.1 μH/m
CE conformity
EMC directive 2004/108/CE in accordance with
EN61000-6-2, EN 61000-6-3
Temperature class T1 ... T4: -40 <Tamb < 85 °C
(ambient temperature) T1 ... T6: -40 <T < 70 °C
amb
Temperature class T1 ... T4: -40 <Tmed < 115 °C
(medium temperature) T1 ... T6: -40 <T < 75 °C
med
For the application in Ex zone you have to respect the conditions
mentioned in the ATEX Type Examination Certificate (SEV 11 ATEX
0129).
You find the certificates and manuals under http://www.baumer.com/
Measuring ranges and overpressure safety
Pressure in bar
Pressure
range
0 ... 60
0 ... 100
0 ... 160
0 ... 250
0 ... 400
0 ... 600
Over
pressure
120
200
320
500
800
1200
2000
3200
Burst
pressure
480
800
1280
2000
3200
4000
4000
4000
0 ... 1600
2013-04-10
Design and specifications subject to change without notice
0 ... 1000
www.baumer.com
Data sheet A11.38
Page 2 / 4
PBMN
industrial High Pressure
Electrical connections
Signal
4...20 at
mA
/ Signal at 0...10 V
Signal at 4...20
mA /atSignal
0...10V
Connector
DIN 43650
M12
4-pins
+VS / +VS
3
IOUT / GND
n.c. / +VOUT
4
1
3
2
n.c. / +VOUT
IOUT / GND
+VS / +VS
1
2
n.c. / +VOUT
earth
earth
Cable
output
Field housing
(Red) / +VS / +VS
Not included in delivery
clamping range: 8...10 mm
n.c. / +VOUT
(Blue) / IOUT / GND
4
3
2
1
IOUT / GND
(White) / n.c. / +VOUT
+VS / +VS
(Shield) / earth
(Shield) / earth
Dimensions (mm)
EN 175301-803A
(DIN 43650 A)
4 pins, IP65
Shielded cable
(1,5 m),
IP67
Ø 6,3
61
71,5
M12
4 pins, IP67
Code 44
1/2-14 NPT
1/4-18 NPT
G 1/2
G 1/4
Code 12
14,5
11
3
24,5
Code 09
14
36
22,5
12 3
25,5
18
13
20,5
Ø6
Code 08
Code 06
G 1/4
G 1/2
Ø 18,8
M14 x 1,5
Ø 25
Ø 26,9
Ø 22,9
G1/2" EN 837
(HEX 23)
1/4" NPT
(HEX 23)
1/2" NPT
(HEX 23)
G1/4"
DIN 3852
(HEX 23)
M14x1.5
cone 60°
(HEX 23)
G1/2"
DIN 3852
(HEX 27)
G1/4" female
(HEX 27)
2013-04-10
G1/4" EN 837
(HEX 23)
Design and specifications subject to change without notice
G 1/4
3
30,5
Ø5
Code 05
23
15
2
22,5
Code 04
Code 03
Code 53
26,5
Code 14
Code 02
Ø 22
Ø 22
Ø 22
www.baumer.com
Data sheet A11.38
Page 3 / 4
PBMN
industrial High Pressure
Ordering details PBMN industrial HP
PBMN
Model
Pressure transmitter
–
2
.
xxx
.
x
.
xx
.
xx
.
xx
.
x
.
x
.
x
.
–
.
3
4
5
Pressure range and unit in bar
0...60
0...100
0...160
0...250
0...400
0...600
0...1000
0...1600
.
B29
B31
B33
B35
B38
B39
B41
B42
Kind of pressure
Relative
.
R
Output signal
4...20mA
0...10V
.
A1
A2
Output connection
M12, 4 pins
DIN 43650, 4 pins
Shielded cable (1.5 m)
.
14
44
53
P ≤ 1000 bar
P ≤ 1000 bar
P ≤ 1000 bar
P ≤ 1000 bar
P ≤ 600 bar
P ≥ 1000 bar
P ≤ 600 bar
P ≤ 1000 bar
Process connection material
Stainless steel 1.4301 AISI 304
.
02
03
04
05
06
08
09
12
.
4
In combination with process connection code 06/09
In combination with process connection code 06/09
Oil filling
Without
.
0
1
3
.
0
Display
Without
ATEX
Without
ATEX according to SEV 11 ATEX 0129 In combination with output signal code A1
Approval
None
Free of oil and grease (pieces in contact with the medium)
Downscale
Without downscale
With downscale
.
0
0
1
0
6
2013-04-10
S0x
Design and specifications subject to change without notice
2
Accuracy
0.5% FS
0.25% FS
0.10% FS
Sealing
Without
NBR
FKM (Viton®)
.
PBMN
Housing material
Stainless steel 1.4404 AISI 316L
Process connection
G¼ EN 837
G½ EN 837
¼ NPT
½ NPT
G¼ DIN 3852
M14x1.5 cone 60°
G½ DIN 3852
G¼ female
x
www.baumer.com
Data sheet A11.38
Page 4 / 4