Digital ES Modulevel w/HART Communication and Analog EZ

®
Digital ES Modulevel
w/HART Communication
and Analog EZ Modulevel
Electronic Liquid Level
Transmitters
Digital ES and Analog EZ Modulevels are advanced, intrinsically safe two-wire instruments, utilizing simple buoyancy
principle to detect and convert liquid level changes into a
stable 4–20 mA output signal. The linkage between the level
sensing element and output electronics greatly simplifies
mechanical design and construction. The in-line vertical
design of the transmitter reduces instrument weight and
simplifies installation.
The Digital ES Modulevel has microprocessor-based electronics with HART compatible output, in addition to the
standard 4–20 mA DC output. The Analog EZ Modulevel
provides a 4–20 mA DC output only.
Digital ES Modulevel Features
• HART network compatible.
• Remote calibration without moving level via
HART compatible hand
held unit.
• Change specific gravity
without stopping process
via HART compatible
hand held unit.
• Push button program
local calibration.
• Continuous self-test with
22 mA DC fault signal and
digital warning message.
• Signal damping may be
changed without stopping process via HART
compatible hand held
unit.
• May be recalibrated without moving the level in
tank.
Digital ES and Analog EZ Modulevel Features
• Two-wire, loop-powered,
intrinsically safe.
• Cast iron, NEMA 4X/7/9
housing.
• Field selectable direct or
reverse output.
• Field wiring in isolated
junction box.
• Range spring suppresses
the effect of turbulence to
give stable output signal.
• Special conduit seals prohibit
moisture
and
condensation seepage
into electronics.
• Specific gravity to as low
as 0.11.
• Level ranges from 14 to 120
inches (356 to 3048 mm).
• Non-interacting zero and
span.
• Interface option available.
• 4–20 mA output signal.
• Analog meter available.
• Calibration stand available for bench calibration.
• CSA and FM approved for
hazardous locations.
• Process temperatures to
600° F (315° C) for nonsteam applications.
• Flanged top mounting or
external cage with
side/side or side/bottom
connections.
• Emission and immunity
compliance to EN50 081-2
and EN50 082-2.
• 316 SS displacer and
internal trim on standard
models.
Applications
• Feedwater heaters
• Condensate drip pots
• Scrubbers
• Separators
• Receivers
• Flash tanks
• Knock-out drums
• Boilers
Worldwide level and flow solutions
Principle of operation
Liquid level change acts upon the spring supported displacer causing vertical motion of a core within a linear variable
differential transformer (LVDT).
The enclosing tube acts as a static isolation barrier between
the LVDT and the process media. As the core position
changes with liquid level, voltages are induced in the secondary windings of the LVDT. These signals are processed
in the electronic circuitry and used to control the current in
the 4–20 mA output current loop.
Digital ES transmitters add the HART output in addition to
the analog 4–20 mA DC output.
,,
,
Electrical enclosure
Printed circuit board
LVDT
Moving LVDT core
External span and
zero adjustment (EZ only)
Terminal junction box
Potted entrance seal
Enclosing tube
Range spring
Displacer
External cage
Hand held option
Digital ES models are compatible with Rosemount, Inc.
model 275 D9E (English version) Hand Held Communicator.
Programming must be added to the HART program for:
• Dry set point
• Set specific gravity
• 20 mA by percentage
• Damping
Contact authorized HART distributors for ES program
addition. New hand held communicators which include the
ES program are available through Magnetrol.
HART Hand Held Communicator
Magnetrol Part Number 089-5213-01X
2
Specifications
Description
Power supply at transmitter
Specific gravity range
Process Connections
Output signal
Max. loop resistance
Level range
Materials of construction
Linearity (independent)
Repeatability
Ambient temperature limits
Process temperature ➁
Temperature effect
Digital ES Modulevel Specifications
Analog EZ Modulevel Specifications
12 to 36 VDC
120 VAC, 50/60 Hz
240 VAC, 50/60 Hz
0.11 to 2.20 SGU
NPT, socket weld or flanged
4–20 mA DC direct or reverse acting
4–20 mA DC field selectable
HART compatible
direct or reverse acting
420 ohms at 24 VDC
480 ohms at 24 VDC
Limited only to displaced length. From fractional inches to 10 feet (3 m) or more.
Chambers: carbon steel or 316/316L stainless steel
Wetted components: 304 or 316 stainless steel.
0.25% of full span ➀
0.20% of full span ➀
Electronics: -40° F to +160° F (-40° C to +71° C)
Steam applications: -20° F to +500° F (-29° C to +260° C)
Non-steam applications: -20° F to +600° F (-29° C to +315° C)
Maximum zero shift is 0.031% of range per ° F from 0° F to +160° F.
14 to 36 VDC
➀ These performance characteristics appy to units measuring liquid level; interface measurement units may not exhibit the same performance.
➁ Minimum temperatures given are for carbon steel construction materials. Complete stainless steel is recommended for lower process
temperatures. Maximum temperatures given are based on ambient temperatures up to +120° F (+49° C) on models without cooling fins.
Higher ambient temperatures require reduced process temperatures.
Agency approvals
Agency
FM ➂
Approval
EXP/I/1/BCD,
DIP/II, III/1/EFG
99-5031 – Entity
IS/I, II, III/1/BCDEFG
CSA ➂
Class I, Div. 1,
Groups B, C, & D
Class II, Div. 1
Groups E, F, & G
Class I, Div. 1,
Groups A, B, C, & D
Class II, Div. 1,
Groups E, F, & G
Intrinsically safe
when connected
through a certified
safety barrier rated
≤28 V and ≥300 ohms
EEx d IIC T6
EEx ib IIC T4
Cenelec
EEx ia IIC T6 (ambient
temp. to 40° C/104° F)
EEx ia IIC T5 (ambient
temperature to 55° C/
131° F)
Intrinsic safety
Models
E5X-XXXX,XE5X-XXXX,
E6X-XXXX or XE6X-XXX with
Transmitter Codes EZA, B, C,
G, L, N, Q, R, S, T, U, V, 1, 2,
3, 4, 5, 6; ESA, G, 1, 4, Q, T
E5X-XXXX or E6X-XXXX
with Transmitter Codes
EZA, G, Q, T, 1, 4
EXX-XXXX with Transmitter
Codes EZA, B, C, G, L, N, Q,
R, S, T, U, V, 1, 2, 3, 4, 5, 6
E6X-1XXX, E6X-2XXX,
E6X-3XXX with Transmitter
Codes EZA, G, 1, 4
EXX-XXX with transmitter
codes EZA, B, C, G, L, N
EXX-XXX with transmitter
codes EZD or EZI
EXX-XXX with transmitter
codes ESD,or ESI
FM Entity parameters
for transmitter codes EZA,
EZG, EZQ, EZT, EZ1, and EZ4
Vmax
Imax
Ci
Li
=
=
=
=
40 V
150 mA
0.005 uF
50 uH
CENELEC Entity parameters
for transmitter codes EZD and EZI
Ui = 28.4 V;
Ui = 28 V;
Ui = 26.4 V;
Ui = 25 V;
Ci = 0.05 uF
Li = 200 uH
li = 80 mA;
li = 93 mA;
li = 99 mA;
li = 125 mA;
Pi = 0.57 W; or
Pi = 0.65 W; or
Pi = 0.66 W; or
Pi = 0.78 W
CENELEC Entity parameters
for transmitter codes ESD and ESI
Ui = 28.4 V; li = 94 mA;
Ci = 72 uF
Li = 550 uH
Pi = 0.67 W
EXX-XXX with transmitter
codes ESD,or ESI
These units have been tested to EN 50081-2 and EN 50082-2 and
are in compliance with the EMC Directive 89/336/EEC.
➂ FM and CSA approvals pending on Digital ES models.
3
Expedite ship plan
Certain Analog EZ
Modulevel instruments are
available for quick shipment,
usually within one week
after factory receipt of a
purchase order, through the
Selection data
Expedite Ship Plan (ESP).
Models covered by ESP
service are conveniently
color coded in the selection
data chart below. To take
advantage of ESP, simply
Digital ES and Analog EZ
transmitters are identified
by a ten digit alphanumeric
part numbering system. The
part number describes model
configuration, materials of
construction, level ranges,
and other options vital to
the performance and function of the instrument.
Model
Code
Mounting
Arrangement
Materials of Construction
Cage or Flange
Displacer &
& Head Assembly
Internal Trim➀
E61
E62
Flanged Top➅
Fabricated Steel
Fabricated 316 SS
316 SS
316 SS
Fabricated Steel
Fabricated 316 SS
Fabricated Steel
Fabricated 316 SS
316 SS
316 SS
316 SS
316 SS
Side/Side
2 Specific gravity and temperature
Steam applications➁
Code
Liquid Specific
Gravity Range
300° F max. 400° F max.➃ 500° F max.➃➄
(149° C max.) (204° C max.) (260° C max.)
0.11–0.54
0.55–1.09
1.10–2.20
1
2
3
7
8
9
7
8
9
4 Level range
5 Transmitter electronics
4 Level range➅
Code
A
400° F max. 500° F max.➃ 600° F max.➃➄
(204° C max.) (260° C max.) (315° C max.)
1
2
3
7
8
9
7
8
9
B
C
D
E
F
G
H
I
48
60
72
84
96
108
120
Inches
14
32
mm
356
813 1219 1524 1829 2134 2438 2743 3048
Dia.
2.0
1.25
1.0
.88
.88
.75
.75
.63
.63
mm
50
31
25
22
22
19
19
16
16
5 Transmitter electronics
Integral mount
Input Power
Code
0.11–0.54
0.55–1.09
1.10–2.20
-
Mounting & materials
1 of construction
Non-steam applications➂
Liquid Specific
Gravity Range
-
3 Tank connection
1 Mounting and materials of construction
Side/Bottom
E
sentative for lead times on
larger volume orders as
well as other products and
options.
Specific gravity
2 & temperature
Standard Pressure Models
E63
E64
E65
E66
match color coded model
number codes (standard
dimensions apply). ESP
service may not apply to
orders of ten units of more.
Contact your local reprePart number construction
Analog EZ Transmitter Codes
Use w/Specific Gravity and Temperature
Codes 1, 2, or 3 and Maximum Temperatures
of 300° F (149° C) Steam;
400° F (204° C) Non-Steam
Blind
w/Analog Meter
24 VDC
120 VAC
240 VAC
24 VDC
EZA
EZB
EZC
EZD➆
EZG
EZL
EZN
EZI➆
Digital ES Transmitter Codes
24 VDC
ESA
ESG
24 VDC
ESD➇
ESI➇
3 Tank connection
Model
150 lb.
300 lb.
600 lb.
3 inch
G3
G4
G5
4 inch
H3
H4
H5
6 inch
K3
K4
K5
E61, E62
Model Process Connection
Rating
Size
Type
Code
ANSI Displacer Cage
150 lb.
300 lb.
600 lb.
NPT
C5
C7
C9
Socket weld
C6
C8
C0
E64
Flanged
P3
P4
P5
E65
NPT
D5
D7
D9
E63
E66
4
Remote mount (connecting cable required)
Code
Head Flange Rating
Process
Connection
Size
11⁄2"
2"
Socket weld
D6
D8
D0
Flanged
Q3
Q4
Q5
Input
Power
24 VDC
120 VAC
240 VAC
Analog EZ Transmitter Codes
Use with codes 1, 2, 3, 7, 8, Use with codes 7, 8, or
or 9 ➈ and Maximum
9 ➉ and Maximum
Temperatures of 400° F
Temperatures of 500° F
(204° C) Steam;
(260° C) Steam;
500° F (260° C)
600° F (315° C)
Non-Steam
Non-Steam
w/Analog
w/Analog
Blind
Blind
Meter
Meter
EZ1
EZ2
EZ3
EZ4
EZ5
EZ6
EZQ
EZR
EZS
EZT
EZU
EZV
Digital ES Transmitter Codes
24 VDC
ES1
ES4
ESQ
EST
Connecting cable
Required for remote mount models. Refer to page 5.
High Pressure Models
1 Mounting and materials of construction
Model
Code
Mounting
Arrangement
E51
Flanged Top➅
E53
Side/Bottom
E55
Side/Side
5 Transmitter electronics
Materials of Construction
Cage or Flange
Displacer and
and
Internal
Head Assembly
Trim➀
304 SS
and
316 SS
Fabricated Steel
Integral mount
Input Power
Analog EZ Transmitter Codes
Use w/Specific Gravity and Temperature
Code 2 Only and Maximum Temperatures of
300° F (149° C) Steam;
400° F (204° C) Non-Steam
Blind
w/Analog Meter
24 VDC
120 VAC
240 VAC
24 VDC
2 Specific gravity and temperature
Steam applications➁
EZA
EZB
EZC
EZD➆
Code
Liquid Specific
Gravity Range
300° F max.
(149° C max.)
0.55–1.09
Digital ES Transmitter Codes
400° F max.➃ 500° F max.➃➄
(204° C max.) (260° C max.)
2
8
8
Non-steam applications➂
400° F max.
(204° C max.)
0.55–1.09
500° F max.➃ 600° F max.➃➄
(260° C max.) (315° C max.)
2
8
8
3 Tank connection
Model
Process
Connection
Size
E51
4 inch
6 inch
Model
E53
E55
Code
Head Flange Rating
900 lb.
1500 lb.
2500 lb.
H6
K6
Type
H7
K7
H8
K8
Code
ANSI Displacer Cage Rating
Process Connection
Size
24 VDC
ESA
ESG
24 VDC
ESD➇
ESI➇
Remote mount (connecting cable required)
Code
Liquid Specific
Gravity Range
EZG
EZL
EZN
EZI➆
900 lb.
1500 lb.
2500 lb.
L5
M5
P6
L6
M6
Q6
L7
M7
P7
L8
M8
Q7
L9
M9
P8
L0
M0
Q8
NPT
11⁄2" Socket Weld
Flanged
NPT
2" Socket Weld
Flanged
Analog EZ Transmitter Codes
Use with codes 2 or 8 ➈ and Use with code 8 ➉ and
Maximum Temperatures Maximum Temperatures
of 400° F (204° C)
of 500° F (260° C)
Input
Steam;
Steam;
Power
500° F (260° C)
600° F (315° C)
Non-Steam
Non-Steam
Blind
w/Analog
Meter
Blind
w/Analog
Meter
24 VDC
120 VAC
240 VAC
EZ1
EZ2
EZ3
EZ4
EZ5
EZ6
EZQ
EZR
EZS
EZT
EZU
EZV
24 VDC
ES1
Digital ES Transmitter Codes
ES4
ESQ
EST
Connecting cable
(Required for remote mount models)
Applications which require a remote mount transmitter also
require a connecting cable. Lengths of 1 to 75 feet (30.5 cm to
22.9 meters) are available in increments of 1 foot (30.5 cm). To
order, specify one of the part numbers listed below with the
last two digits representing the cable length required.
For Transmitter codes ES1, ES4, EZ1, 2, 3, 4, 5, and 6
specify remote cable 037-3218-0XX.
4 Level range➅
Code
A
B
C
D
Inches
mm
Dia.
mm
14
356
2.0
50
32
813
1.25
31
48
1219
1.0
25
60
1524
.88
22
For Transmitter codes ESQ, EST, EZQ, R, S, T, U, and V
specify remote cable 037-3220-0XX.
Calibration stand
For bench calibration of transmitter electronics
Part Number: 031-6107-001
➀ Inconel range spring.
➁ Applications measuring water with steam and steam condensate
present at high temperatures.
➂ Applications such as hydrocarbons. Do not use ES/EZ Modulevel
on Dowtherm® or other heat transfer media.
➃ Codes 7, 8, and 9 are supplied with remote mount electronics
and two sets of cooling fins.
➄ Codes 7, 8, and 9 for high temperature applications (500° F or
600° F) utilize transmitter codes ESQ, EST, EZQ, EZR, EZS, EZT,
EZU, and EZV only.
➅ Top mounting models require an adjustable hanger, part number
032-3110-001, when the span is more than 9.31" (236 mm) below
the mounting flange.
➆ Transmitter codes with Cenelec approval EEx ib IIC T4.
➇ Transmitter codes with Cenelec
➈ Specify remote cable assembly 037-3218-0XX.
➉ Specify remote cable assembly 037-3220-0XX.
5
Dimensional specifications
inches (mm)
Standard pressure models: E61, E62, E63, E64, E65, E66
10.75
(273)
8.62
(219)
1" NPT
1/2"
1" NPT
conduit
connector
NPT
Range Spring
Specific Gravity
Rating
A
B
C
.11 to .54
14.06
(357)
19.06
(484)
23.25
(591)
.55 to 1.09
1.10 to 2.20
12.12
(308)
17.12
(435)
21.31
(541)
2.00 (51)
3.50 (89)
2.37 (60)
C ± .19 (5)
Up to 75' (23 m)
of Connecting
Cable, part
number
037-3218-0XX
or
037-3220-0XX,
run in conduit.
Cable must be
ordered separately.
Level range
plus 3.50
(89)
5.00
(127)
3.00
(76)
Remote Mount
Bracket
Pipe
Size
D
E
11⁄2"
3.19
(81)
5.94
(151)
2"
3.19
(81)
6.25
(159)
Level range
plus 8.62
(219)
D
E
Remote Side/Bottom Mount
External Cage Model Codes 7, 8, 9
10.75
(273)
8.62
(219)
1" NPT
conduit
connector
10.75
(273)
8.62
(219)
1" NPT
conduit
connector
B
A
5.00 (127)
Adjustable hanger
cable available
(specify 032-3110-001)
Level
range
Level
range
3.00 (76)
D
E
Integral Top Mount
6
1" NPT drain
(plug not provided)
Integral Side/Side Mount
External Cage Model Codes 1, 2, 3
Dimensional specifications
inches (mm)
High pressure models: E51, E53, E55
10.75
(273)
10.75
(273)
8.62
(219)
8.62
(219)
1" NPT
conduit
connector
B
1" NPT
conduit
connector
B
E
K
F
C
ANSI standard flange
Level
range
Level
range
Mid
Range
M
H
Dia.
(2) 11/2" or 2" NPT
or socket weld
E51 Series with Top Mounting
900, 1500, 2500 lb. Class
L
(2) 11/2" or 2" ANSI
standard flange
(Refer to chart for
class and size.)
G
10.75
(273)
8.62
(219)
E53 Series with Upper Side/Bottom Connections
900, 1500, 2500 lb. Class
1" NPT
conduit
connector
B
E
F
Dimensions
L
M
Outlet Size
Level
range
(2) 11/2" or 2"
ANSI standard
flange
(Refer to chart for
class and size.)
Mid
Range
4.00
(102)
4.38
(111)
11⁄2" NPT or Socket Weld
2" NPT or Socket Weld
3.44
(87)
3.50
(89)
J
(2) 11/2" or 2"
NPT or
socket weld
L
G
Flange Size
& Class
1" NPT
drain
B
C
E
F
1
1 ⁄2" – 900 lb.
2" – 900 lb.
E55 Series with Side/Side Connections
900, 1500, 2500 lb. Class
Dimensions
11⁄2" – 1500 lb.
2" – 1500 lb.
11⁄2" – 2500 lb.
2" – 2500 lb.
16.38 9.31 25.81 9.31
(416) (236) (655) (236)
16.75 9.31 26.19 9.31
(425) (236) (665) (236)
17.62 9.31 27.06 9.31
(447) (236) (687) (236)
G
7.25
(184)
8.18
(208)
7.93
(201)
8.87
(225)
9.06
(230)
9.87
(251)
H
J
K
8.43
(214) 3.44 11.50
9.38 (87) (292)
(238)
9.13
(232) 3.44 12.25
10.13 (87) (311)
(257)
10.25
(267) 3.44 14.00
11.13 (87) (356)
(283)
7
Product warranty
All Magnetrol electronic
level and flow controls are
warranted free of defects in
materials or workmanship
one full year from the date
of original factory shipment.
If returned within the warranty period; and, upon
factory inspection of the
control, the cause of the
claim is determined to be
covered under the warranty;
then, Magnetrol will repair
or replace the control at no
cost to the purchaser (or
owner) other than transportation.
labor claims, direct or consequential damage
or
expense arising from the
installation or use of equipment. There are no other
warranties expressed or
implied, except special
written warranties covering
some Magnetrol products.
Magnetrol shall not be
liable for misapplication,
Quality assurance
The quality assurance system in place at Magnetrol
guarantees the highest
level of quality throughout
the company. Magnetrol is
committed to providing full
customer satisfaction both
in quality products and
quality service.
Magnetrol's quality assurance system is registered
to ISO 9001 and Z299.1
affirming its commitment to
known international quality
standards providing the
strongest assurance of
product/service quality
available.
ASSURED QUALITY & SERVICE COST LESS
5300 Belmont Road • Downers Grove, Illinois 60515-4499 • 630-969-4000 • Fax 630-969-9489 • Website http://www.magnetrol.com
6291 Dorman Road • Mississauga, Ontario L4V-1H2 • 905-678-2720 • Fax 905-678-7407
Heikenstraat 6 • B 9240 Zele, Belgium • 052 45.11.11 • Telex 25944 • Fax 052 45.09.93
Regent Business Ctr., Jubilee Rd. • Burgess Hill, Sussex RH15 9TL U.K. • 01444-871313 • Fax 01444-871317
©1997 Magnetrol International, Incorporated. All rights reserved. Printed in the USA.
Magnetrol and Magnetrol logotype are registered trademarks of Magnetrol International.
The brand and product names contained within this document are trademarks or registered trademarks
of their respective holders.
BULLETIN: 48-105.14
EFFECTIVE: December 1997
SUPERSEDES: August 1996