48-118.6 Modulevel Sales - Magnetrol International

Digital ES II Modulevel® w/HART®
Communication and Analog EZ
Modulevel Electronic Liquid
Level Transmitters
D E S C R I P T I O N
The Digital ES II and Analog EZ Modulevels are
advanced, intrinsically safe two-wire or four-wire
instruments utilizing simple buoyancy principle to
detect and convert liquid level changes into a stable
4–20 mA output signal. The linkage between the level
sensing element and output electronics provides a simple mechanical design and construction. The vertical
in-line design of the transmitter results in low instrument weight and simplified installation. The instrument
comes in a variety of configurations and pressure
ratings for varied applications.
The Digital ES II Modulevel has microprocessor-based
electronics with HART compatible output, in addition
to the standard 4–20 mA output, while the Analog EZ
Modulevel provides a simple 4–20 mA output signal.
T E C H N O L O G Y
Changing buoyancy forces caused by liquid level
change acting upon the spring supported displacer
cause vertical motion of a core within a linear variable
differential transformer.
As the core position changes with liquid level, voltages
are induced across the secondary windings of the
LVDT. These signals are processed in the electronic
circuitry and used to control the current in the
4–20 mA current loop. The enclosing tube acts as a
static isolation barrier between the LVDT and the
process media.
A P P L I C A T I O N S
•
•
•
•
•
Feedwater heaters
Scrubbers
Receivers
Separators
Interface Level
•
•
•
•
Knock-out drums
Flash tanks
Condensate drip pots
Boilers
F E A T U R E S
D I G I T A L
A N A L O G
E S
E Z
A N D
M O D U L E V E L
D I G I T A L
E S
M O D U L E V E L
• Two-wire, loop-powered, intrinsically safe
• HART network compatible
• Cast iron, NEMA 4X, Cl I Div 1 Groups B, C, D
• Remote calibration without level movement via
HART compatible handheld unit
housing
• Field selectable direct or reverse acting output
• Standard output range from 3.8 to 20.5 mA
• Field wiring in isolated junction box
• Specific gravity adjustment without stopping
process via HART compatible handheld unit
• Head rotatable through 360°
• Range spring suppresses effects of turbulence to
produce stable output signal.
• Special conduit seals prohibit moisture and condensation seepage into electronics enclosure.
• Specific gravity as low as 0.23
• Level ranges from 14 to 120 inches
(356 to 3048 mm)
• Push-button program local calibration
• Continuous self-test with 22 mA or 3.6 mA fault indication fully compliance with NAMUR NE 43
• HART indication of approaching fault
• Signal damping adjustment without stopping
process via HART compatible handheld unit
• Recalibration without level movement
• Non-interacting zero and span
• Digital LCD meter option with plug connectors
• Interface option available
• 15 unit multi-drop capability
• 4–20 mA output signal
• Signal sampling 15 times per second
• Analog meter available
• 12 VDC or less turn on voltage
• Spring protector standard
• Maximum loop resistance of 545 ohms at 24 VDC
• Calibration stand available for bench calibration
• IS, XP and Non-incendive approvals by FM, CSA
and ATEX
• Process temperatures to +600° F (+315° C) for
non-steam applications
• Flanged top mounting or external cage with
side/side or side/bottom connections
• Emission and immunity compliance to EN50081-2
and EN50082-2
• Special options, materials of construction and custom engineered features available (consult factory)
HANDHELD
OPTION
Digital ES II models are compatible with Rosemount,
Inc. model 275 D9E (English version) Handheld
Communicator. Programming must be added to the
HART program for:
•
•
•
•
Dry set point
Set specific gravity
20 mA by percentage
Damping
Contact authorized HART distributors for ES II
program addition.
2
P H Y S I C A L
S P E C I F I C A T I O N S
Measured Variable:
Liquid level or liquid interface level
Physical Range:
Up to 120" (300 cm) based on displacer length
Chamber Materials:
Carbon steel, 316/316L stainless steel
Wetted Parts:
900# or greater construction, 304/304L,
316/316L stainless steel and inconel
600# or less construction, 316/316L stainless steel and inconel
Process Connection:
Tank top: 3", 4", 6" ANSI flange
Chambered: 11⁄2", 2" NPT, socketweld or ANSI flanges
Process Temp Range ➀:
Steam applications: -20° to +500° F (-29° to +260° C)
Non-steam applications: -20° to +600° F (-29° to +315° C)
Maximum Process Pressure:
5100 psig @ +100° F (294 bar @ +38° C)
Housing Material:
Polymer coated cast iron
Cable Entry:
1" NPT
➀ Maximum temperatures given are based on ambient temperatures up to +120° F (+49° C). Higher ambient temperatures require reduced
process temperatures. Minimum temperatures given are for carbon steel construction materials. Complete stainless steel construction
may be used for lower process temperatures.
D I G I T A L
Signal Output:
E S
II
S P E C I F I C A T I O N S
Analog 4–20 mA direct or reverse acting with HART digital signal
Analog 3.8–20.5 useable (meets NAMUR NE 43)
Analog or Digital 0–100%
Loop Resistance:
545 ohms @ 24 VDC
Damping:
Adjustable 0–60 seconds
Fault:
3.6 or 22 mA, selectable
User Interface:
Three button keypad with three LEDs and/or HART communicator
Indication:
3 LEDs on PCB for calibration and functional checks
Analog or digital meters (optional)
Power (at terminals):
12 VDC to 36 VDC
Sampling Rate:
Transmitter 15/second
Digital Meter 1.33/second
Menu Language:
English
3
A N A L O G
E Z
Signal Output:
S P E C I F I C A T I O N S
Analog 4–20 mA direct or reverse acting
Analog 0–100%
Loop Resistance:
480 ohms @ 24 VDC
Alarm:
22 mA fault
User Interface:
Zero and span potentiometers
Indication:
Analog meter (optional)
Power (at terminals):
12 to 36 VDC
120 VAC, 50/60 Hz
240 VAC, 50/60 Hz
E S
II
A N D
E Z
Linearity (independent):
P E R F O R M A N C E
LVDT: ±0.25% of full span
➀
Mechanical/electrical: ±0.25% of full span
➀
Repeatability:
±0.20% of full span
Resolution:
0.05 % of range ±1 digit
Ambient Temp. Effect:
Maximum zero shift is 0.031% of range/°F
Operating Temp. Range:
-40° to +160° F (-40° to +70° C)
Digital Meter Temp. Range:
-4° to +160° F (-20° to +70° C)
Storage Temp. Range:
-40° to +185° F (-40° to +85° C)
Electromagnetic Compatibility:
Meets CE Requirements (EN 50081-2, EN 50082-2)
➀ These performance characteristics apply to units measuring liquid level. Interface measurement units may not exhibit the same performance.
A G E N C Y
A P P R O V A L S
AGENCY
MODEL APPROVED
APPROVAL CLASSES
FM
XEXX-XXXX with transmitter codes:
Explosion Proof
EZA, B, C, E, F, G, L, N
Class I, Div 1; Groups B, C, D
ESA, E, F, G, 7, 9
Class II, Div 1; Groups E, F, G
GZH, K, Q, R, S, T, U, V, 2, 3, 5, 6
Class III, NEMA 4X
GSH, K, Q, T, 4, 7
RZW, X
RSW, X, 4
XEXX-XXXX with transmitter codes:
Explosion Proof w/
RZQ,T
Intrinsically Safe Connections
RSQ, T, Z
Class I, II, III, Div 1, Groups B,C,D,E,F,G
Nema 4X
Entity
EXX-XXXX with transmitter codes:
Intrinsically Safe
EZD, H, I, K
Class I, Div 1; Groups A, B, C, D
ESD, H, I, J, K, 8, 9
Class II, Div 1; Groups E, F, G
Class III, NEMA 4X
Entity
Continued on next page
4
A G E N C Y
AGENCY
FM
A P P R O V A L S
MODEL APPROVED
APPROVAL CLASSES
EXX-XXXX with transmitter codes:
Non-Incendive
EZA, G
suitable for:
ESA, E, F, G, 7, 9
Class I, Div 2, Groups A, B, C, D
GZH, K, Q, T ➁
Class II, Div 2, Groups F, G
GSH, K, Q, T, 4, 7 ➁
Class III, Div. 2, NEMA 4X
RZW, X
AGENCY
RSW,
4
MODELX,
APPROVED
CSA
XE5X-XXXX with transmitter codes:
Explosion Proof
EZA, B, C, E, F, G, L, N
Class I, Div 1, Groups B, C, D
ESA, E, F, G, 7, 9
Class II, Div 1, Groups E, F, G
GZH, K, Q, R, S, T, U, V, 2, 3, 5, 6
Class III, Type 4X
APPROVAL CLASSES
GSH, K, Q, T, 4, 7
RZW, X
RSW, X, 4
E5X-XXXX with transmitter codes:
Intrinsically Safe
EZD, H, I, K
Class I, Div 1, Groups A, B, C, D
ESD, H, I, J, K, 8
Class II, Div 1, Groups E, F, G
GZH, K, Q, T ➂
Class III, Type 4X
GSH, K, Q, T, 4, 7 ➂
Entity
RZQ, T
RSQ, T, Z
E5X-XXXX with transmitter codes:
Non-Incendive
EZD, H, I, K
suitable for:
ESD, H, I, J, K, 8
Class I, Div 2, Groups A, B, C, D
GZH, K, Q, T ➂
Class II, Div 2, Groups E, F, G
GSH, K, Q, T, 4, 7 ➂
Class III, Type 4X
RZQ, T
RSQ, T, Z
ATEX
XEXX-XXXX, EXX-XXXX with transmitter codes
Explosion Proof ➃
EZA, E, F, G
ATEX Ex II 1/2 G EEx d IIC T6
ESA, E, F, G, 7, 9
IP66
RZW, X
RSW, X, 4
EXX-XXXX with transmitter codes
Intrinsically Safe
ESD, I, H, K
ATEX Ex II 1 G EEx ia IIC T6
RSQ, T
IP66
EXX-XXXX with transmitter codes
Intrinsically Safe
ESJ, 8
ATEX Ex II 1 G EEx ia IIC T5
RSZ
IP66
These units have been tested to EN 50081-2
and EN 50082-2 and are in compliance with
the EMC Directive 89/336/EEC.
➁ Field wiring must be installed in conduit.
➂ If IS or NI CSA name plate is required, this must be specified at time of
order placement.
➃ ATEX EP approval available on standard 900#, 1500#, and 2500# models.
150#, 300#, and #600 models require modification for ATEX EP approval
and must be “X’d” for a heavy wall e-tube.
5
D I M E N S I O N A L
STANDARD
PRESSURE
S P E C I F I C A T I O N S
MODELS
E5A,
E5B,
E5C,
E5D,
E5E,
E5F
19.10
(485)
10.75
(273)
8.75
(222)
8.75
(222)
1" NPT
1/2"
A
NPT
2.00 (51)
A
3.50 (89)
2.75 (70)
D
D
Level range
Up to 75' (23 m)
of connecting
cable, part
number
037-3218-0XX
or
037-3220-0XX,
run in conduit.
Cable must be
ordered separately.
Level
range
H
J
G
E
E
1" NPT drain
(plug not provided)
F
F
HT Integral Side/Bottom Mount
Fourth Digit Codes G, R, T
Remote Side/Side Mount
Fourth Digit Codes A, B, C
10.75
(273)
8.75
(222)
1" NPT
conduit
connector
A
ANSI standard flange
B
C
Dia.
E5A/E5B Series with Integral Top Mounting
Fourth Digit codes J, K, L
6
1" NPT
conduit
connector
D I M E N S I O N A L
I N C H E S
Cage Pressure
Rating
S P E C I F I C A T I O N S
( M M )
Process
Conn. Size
Spring
S.G. Range
B
C
D
E
F
G
H
J
0.23 – 0.54
6.75
(171)
9.31
(236)
9.31
(236)
3.19
(81)
7.00
(178)
3.00
(76)
3.00 + range
(76 + range)
5.43
(138)
0.55 – 1.09
4.75
(121)
7.31
(186)
7.31
(186)
3.19
(81)
7.00
(178)
3.00
(76)
3.00 + range
(76 + range)
5.43
(138)
1.10 – 2.20
4.75
(121)
7.31
(186)
7.31
(186)
3.19
(81)
7.00
(178)
3.00
(76)
3.00 + range
(76 + range)
5.43
(138)
0.23 – 0.54
6.75
(171)
9.31
(236)
9.31
(236)
3.31
(84)
7.13
(181)
3.00
(76)
3.00 + range
(76 + range)
5.55
(141)
0.55 – 1.09
4.75
(121)
7.31
(186)
7.31
(186)
3.31
(84)
7.13
(181)
3.00
(76)
3.00 + range
(76 + range)
5.55
(141)
1.10 – 2.20
4.75
(121)
7.31
(186)
7.31
(186)
3.31
(84)
7.13
(181)
3.00
(76)
3.00 + range
(76 + range)
5.55
(141)
11⁄2"
0.55 – 1.09
6.75
(171)
9.31
(236)
9.31
(236)
3.19
(81)
7.00
(178)
3.00
(76)
3.00 + range
(76 + range)
5.43
(138)
2"
0.55 – 1.09
6.75
(171)
9.31
(236)
9.31
(236)
3.31
(84)
7.13
(181)
3.00
(76)
3.00 + range
(76 + range)
5.55
(141)
11⁄2"
0.55 – 1.09
6.75
(171)
9.31
(236)
9.31
(236)
4.00
(102)
7.93
(201)
3.44
(87)
3.44 + range
(87 + range)
9.13
(232)
2"
0.55 – 1.09
6.75
(171)
9.31
(236)
9.31
(236)
4.38
(111)
8.87
(225)
3.44
(87)
3.44 + range
(87 + range)
10.13
(257)
11⁄2"
0.55 – 1.09
6.75
(171)
9.31
(236)
9.31
(236)
4.00
(102)
9.06
(230)
3.44
(87)
3.44 + range
(87 + range)
10.25
(260)
2"
0.55 – 1.09
6.75
(171)
9.31
(236)
9.31
(236)
4.38
(111)
9.87
(251)
3.44
(87)
3.44 + range
(87 + range)
11.13
(283)
11⁄2"
150#, 300# &
600# ANSI
2"
900# ANSI
1500# ANSI
2500# ANSI
Cage Pressure
Rating
150# ANSI
300# ANSI
600# ANSI
900# ANSI
Dimension
Head
Flange Size
'A' Dimension
A, B, C, Q, R, T
D, E, F
J, K, L,
M, N, P
3"
10.69
(271)
18.69
(475)
6.69
(170)
14.69
(372)
4"
10.69
(271)
18.69
(475)
6.69
(170)
14.69
(372)
6"
10.75
(273)
18.75
(476)
6.75
(171)
14.75
(375)
3"
10.88
(276)
18.88
(480)
6.88
(175)
14.88
(378)
4"
11.00
(279)
19.00
(483)
7.00
(178)
15.00
(381)
6"
11.19
(284)
19.19
(487)
7.19
(183)
15.19
(386)
3"
11.25
(286)
19.25
(489)
7.25
(184)
15.25
(387)
4"
11.50
(292)
19.50
(495)
7.50
(190)
15.50
(394)
6"
11.88
(302)
19.88
(505)
7.88
(200)
15.88
(403)
3"
11.50
(292)
19.50
(495)
7.50
(190)
15.50
(394)
4"
11.75
(298)
19.75
(502)
7.75
(197)
15.75
(400)
6"
12.19
(310)
20.19
(513)
8.19
(208)
16.19
(411)
4"
12.13
(308)
20.13
(511)
8.13
(206)
16.13
(410)
6"
13.25
(337)
21.25
(540)
9.25
(235)
17.25
(438)
4"
13.00
(330)
21.00
(533)
9.00
(229)
17.00
(432)
6"
14.25
(362)
22.25
(566)
10.25
(260)
18.25
(464)
1500# ANSI
2500# ANSI
7
S T E A M
M O D E L
A P P L I C A T I O N S
N U M B E R
Models available for quick shipment, usually within one week after factory
receipt of a purchase order, through the Expedite Ship Plan (ESP).
DESIGN TYPE
E 5
Standard design EZ Modulevel
MOUNTING AND CHAMBER MATERIALS
Flanged top ➀
steel
316 SS ➁
A
B
Cage side/Bottom
steel
316 SS ➁
C
D
Cage Side/side
steel
316 SS ➁
E
F
Tank Connection
Chamber Material
code
➀ Adjustable 8' hanger cable (p/n 32-3110-001), required when distance
from flange face to top of displacer must be greater than 9.31".
➁ Bolting material is alloy steel.
SPECIFIC GRAVITY AND PROCESS TEMPERATURE
Integral
HT integral
or remote
Integral or Remote
+300° F
(+150° C)
+400° F
(+200° C)
+450° F
(+230° C)
+500° F
(+260° C)
K
B
N
R
Transmitter Mounting
Maximum Process Temperature
0.55 – 1.09 specific gravity (all pressures) ➂
➂ Consult factory for lower specific gravity design.
TANK CONNECTION
Top mounted connection type
External cage models
ANSI Cage rating
ANSI HEAD Flange rating
RF
RF
RF
RF
RF
RF ➃
150 lbs 300 lbs 600 lbs 900 lbs 1500 lbs 2500 lbs Size
RF
RF
RF
RF
RF
RF ➃
150 lbs 300 lbs 600 lbs 900 lbs 1500 lbs 2500 lbs Size/Type
G3
G4
G5
G6
n/a
n/a
3"
C5
C7
C9
L5
L7
L9
11⁄2" NPT
H3
H4
H5
H6
H7
H8
4"
C6
C8
C0
M5
M7
M9
11⁄2" S.W.
K3
K4
K5
K6
K7
K8
6"
P3
P4
P5
P6
P7
P8
11⁄2" flanged
➃ Maximum pressure rating is 5100 psig (351 bar).
D5
D7
D9
L6
L8
L0
2" NPT
D6
D8
D0
M6
M8
M0
2" S.W.
Q3
Q4
Q5
Q6
Q7
Q8
2" flanged
LEVEL RANGE
All Pressures
Up to 600 lbs
14
356
32
813
48
1219
60
1524
72
1829
84
2134
96
2438
108
2743
120
3048
inches
mm
A
B
C
D
E
F
G
H
I
code
TRANSMITTER – ELECTRONICS (see opposite page)
E 5
8
S T E A M
M O D E L
A P P L I C A T I O N S
N U M B E R
TRANSMITTER CONFIGURATION AND ACCESSORIES
+300° F (+150° C) (Fourth digit K only)
Integral
Remote
Digital Analog
Digital Analog Input Voltage
ESA
EZA
n/a
n/a
24 VDC
n/a
EZB
n/a
n/a
120 VAC
n/a
EZC
n/a
n/a
240 VAC
ESD
EZD
n/a
n/a
24 VDC
ESG
EZG
n/a
n/a
24 VDC
ESI
EZI
n/a
n/a
24 VDC
n/a
EZL
n/a
n/a
120 VAC
n/a
EZN
n/a
n/a
240 VAC
ESJ
n/a
n/a
n/a
24 VDC
ES9
n/a
n/a
n/a
24 VDC
Display
None
None
None
None
Analog
Analog
Analog
Analog
Digital
Digital
Agency Approval
EP – FM, CSA ➄
EP – FM, CSA
EP – FM, CSA
IS/NI – FM, CSA, ATEX ➅
EP – FM, CSA ➄
IS/NI – FM, CSA, ATEX ➅
EP – FM, CSA
EP – FM, CSA
IS/NI – FM, CSA
EP – FM, CSA ➄
+400° F (+200° C) (Fourth digit B only)
+450° F (+230° C) (Fourth digit N only)
Integral
Remote
Digital Analog
Digital Analog Input Voltage
ESE
EZE
GSH
GZH
24 VDC
ESH
EZH
n/a
n/a
24 VDC
n/a
n/a
n/a
GZ2
120 VAC
n/a
n/a
n/a
GZ3
240 VAC
ESF
EZF
GSK
GZK
24 VDC
ESK
EZK
n/a
n/a
24 VDC
n/a
n/a
n/a
GZ5
120 VAC
n/a
n/a
n/a
GZ6
240 VAC
ES7
n/a
GS7
n/a
24 VDC
ES8
n/a
n/a
n/a
24 VDC
Display
None
None
None
None
Analog
Analog
Analog
Analog
Digital
Digital
Agency Approval
EP – FM, CSA ➄➆
IS/NI – FM, CSA, ATEX ➅
EP – FM, CSA
EP – FM, CSA
EP – FM, CSA ➄➆
IS/NI – FM, CSA, ATEX ➅
EP – FM, CSA
EP – FM, CSA
EP – FM, CSA ➄➆
IS/NI – FM, CSA
+500° F (+250° C) (Fourth digit R only)
HT Integral
Remote
Digital Analog
Digital Analog Input Voltage
RSQ
RZQ
n/a
n/a
24 VDC
RSW
RZW
GSQ
GZQ
24 VDC
n/a
n/a
n/a
GZR
120 VAC
n/a
n/a
n/a
GZS
240 VAC
RST
RZT
n/a
n/a
24 VDC
RSX
RZX
GST
GZT
24 VDC
n/a
n/a
n/a
GZU
120 VAC
n/a
n/a
n/a
GZV
240 VAC
RS4
n/a
GS4
n/a
24 VDC
RSZ
n/a
n/a
n/a
24 VDC
Display
None
None
None
None
Analog
Analog
Analog
Analog
Digital
Digital
Agency Approval
IS/NI – FM, CSA, ATEX ➅
EP – FM, CSA ➄➆
EP – FM, CSA
EP – FM, CSA
IS/NI – FM, CSA, ATEX ➅
EP – FM, CSA ➄➆
EP – FM, CSA
EP – FM, CSA
EP – FM, CSA ➄➆
IS/NI – FM, CSA
➄ ATEX EP approval available on standard 900#, 1500#, and 2500# models. 150#, 300#, and
#600 models require modification for ATEX EP approval and must be “X’d” for a heavy wall
e-tube.
➅ ATEX IS/NI approval applies to Digital ES II only. Analog version is not ATEX IS/NI approved
➆ ATEX approval on integral and HT integral mount heads only.
REMOTE CONNECTING CABLE
Up to +400° F (+204° C), specify cable 037-3218-0XX, where last two
digits are cable length in feet from 1–75 feet.
Last 3 Digits of Model Number
Up to +500° F (+260° C), specify cable 037-3220-0XX, where last two
digits are cable length in feet from 1–75 feet.
9
N O N - S T E A M
M O D E L
A P P L I C A T I O N S
N U M B E R
DESIGN TYPE
E 5
Standard design EZ Modulevel
MOUNTING AND CHAMBER MATERIALS
Flanged top ➀
Cage side/bottom
Cage side/side
steel
316 SS ➁
steel
316 SS ➁
steel
316 SS ➁
A
B
C
D
E
F
Tank Connection
Chamber Material
code
➀ Adjustable 8' hanger cable (p/n 32-3110-001), required when distance
from flange face to top of displacer must be greater than 9.31".
➁ Bolting material is alloy steel.
SPECIFIC GRAVITY AND PROCESS TEMPERATURE
Integral
+300° F
(+150° C)
+400° F
+450° F
(+200° C) (+230° C)
Integral or
remote
Integral
HT Integral
or remote
+500° F
(+260° C)
+550° F
(+290° C)
+600° F
(+315° C)
Transmitter Mounting
Maximum Process Temperature
J
A
M
A
D
Q
0.23 – 0.54 specific gravity (up to 600 lbs) ➂
K
B
N
B
E
R
0.55 – 1.09 specific gravity (all pressures)
L
C
P
C
F
T
1.10 – 2.20 specific gravity (up to 600 lbs)
➂ Consult factory for lower specific gravity design
TANK CONNECTION
Top mounted connection type
External cage models
ANSI Cage rating
ANSI HEAD Flange rating
RF
RF
RF
RF
RF
RF ➃
150 lbs 300 lbs 600 lbs 900 lbs 1500 lbs 2500 lbs Size
RF
RF
RF
RF
RF
RF ➃
150 lbs 300 lbs 600 lbs 900 lbs 1500 lbs 2500 lbs Size/Type
G3
G4
G5
G6
n/a
n/a
3"
C5
C7
C9
L5
L7
L9
11⁄2" NPT
H3
H4
H5
H6
H7
H8
4"
C6
C8
C0
M5
M7
M9
11⁄2" S.W.
K3
K4
K5
K6
K7
K8
6"
P3
P4
P5
P6
P7
P8
11⁄2" flanged
D5
D7
D9
L6
L8
L0
2" NPT
➃ Maximum pressure rating is 5100 psig (351 bar).
D6
D8
D0
M6
M8
M0
2" S.W.
Q3
Q4
Q5
Q6
Q7
Q8
2" flanged
LEVEL RANGE
All Pressures
Up to 600 lbs
14
356
32
813
48
1219
60
1524
72
1829
84
2134
96
2438
108
2743
120
3048
inches
mm
A
B
C
D
E
F
G
H
I
code
TRANSMITTER – ELECTRONICS (see opposite page)
E 5
10
N O N - S T E A M
M O D E L
A P P L I C A T I O N S
N U M B E R
TRANSMITTER CONFIGURATION AND ACCESSORIES
+300° F (+150° C)
+400° F (+200° C)
+450° F (+230° C)
+550° F (+290° C)
Integral
Digital Analog
ESA
EZA
n/a
EZB
n/a
EZC
ESD
EZD
ESG
EZG
ESI
EZI
n/a
EZL
n/a
EZN
ESJ
n/a
ES9
n/a
(Fourth digits J, K, L only)
(Fourth digits A, B, C only)
(Fourth digits M, N, P only)
(Fourth digits D, E, F only)
Remote
Digital Analog Input Voltage
n/a
n/a
24 VDC
n/a
n/a
120 VAC
n/a
n/a
240 VAC
n/a
n/a
24 VDC
n/a
n/a
24 VDC
n/a
n/a
24 VDC
n/a
n/a
120 VAC
n/a
n/a
240 VAC
n/a
n/a
24 VDC
n/a
n/a
24 VDC
Display
None
None
None
None
Analog
Analog
Analog
Analog
Digital
Digital
Agency Approval
EP – FM, CSA ➄
EP – FM, CSA
EP – FM, CSA
IS/NI – FM, CSA, ATEX ➅
EP – FM, CSA ➄
IS/NI – FM, CSA, ATEX ➅
EP – FM, CSA
EP – FM, CSA
IS/NI – FM, CSA
EP – FM, CSA ➄
+500° F (+260° C) (Fourth digits A, B, C only)
Integral
Remote
Digital Analog
Digital Analog Input Voltage
ESE
EZE
GSH
GZZ
24 VDC
ESH
EZH
n/a
n/a
24 VDC
n/a
n/a
n/a
GZ2
120 VAC
n/a
n/a
n/a
GZ3
240 VAC
ESF
EZF
GSK
GZK
24 VDC
ESK
EZK
n/a
n/a
24 VDC
n/a
n/a
n/a
GZ5
120 VAC
n/a
n/a
n/a
GZ6
240 VAC
ES7
n/a
GS7
n/a
24 VDC
ES8
n/a
n/a
n/a
24 VDC
Display
None
None
None
None
Analog
Analog
Analog
Analog
Digital
Digital
Agency Approval
EP – FM, CSA ➄➆
IS/NI – FM, CSA, ATEX ➅
EP – FM, CSA
EP – FM, CSA
EP – FM, CSA ➄➆
IS/NI – FM, CSA, ATEX ➅
EP – FM, CSA
EP – FM, CSA
EP – FM, CSA ➄➆
IS/NI – FM, CSA
+600° F (+315° C) (Fourth digits Q, R, T only)
HT Integral
Remote
Digital Analog
Digital Analog Input Voltage
RSQ
RZQ
n/a
n/a
24 VDC
RSW
RZW
GSQ
GZQ
24 VDC
n/a
n/a
n/a
GZR
120 VAC
n/a
n/a
n/a
GZS
240 VAC
RST
RZT
n/a
n/a
24 VDC
RSX
RZX
GST
GZT
24 VDC
n/a
n/a
n/a
GZU
120 VAC
n/a
n/a
n/a
GZV
240 VAC
RSZ
n/a
n/a
n/a
24 VDC
RS4
n/a
GS4
n/a
24 VDC
Display
None
None
None
None
Analog
Analog
Analog
Analog
Digital
Digital
Agency Approval
IS/NI – FM, CSA, ATEX ➅
EP – FM, CSA ➄➆
EP – FM, CSA
EP – FM, CSA
IS/NI – FM, CSA, ATEX ➅
EP – FM, CSA ➄➆
EP – FM, CSA
EP – FM, CSA
IS/NI – FM, CSA
EP – FM, CSA ➄➆
➄ ATEX EP approval available on standard 900#, 1500#, and 2500# models. 150#, 300#, and #600
models require modification for ATEX EP approval and must be “X’d” for a heavy wall e-tube.
➅ ATEX IS/NI approval applies to Digital ES II only. Analog version is not ATEX IS/NI approved
➆ ATEX approval on integral and HT integral mount heads only.
REMOTE CONNECTING CABLE
Last 3 Digits of Model Number
Up to +500° F (+260° C), specify cable 037-3218-0XX, where last two
digits are cable length in feet from 1–75 feet.
Up to +600° F (+316° C), specify cable 037-3220-0XX, where last two
digits are cable length in feet from 1–75 feet.
11
Q U A L I T Y
The quality assurance system in place at
Magnetrol guarantees the highest level of
quality throughout the company. Magnetrol
is committed to providing full customer
satisfaction both in quality products and
quality service.
Magnetrol’s quality assurance system is
registered to ISO 9001 affirming its commitment to known international quality
standards providing the strongest assurance
of product/service quality available.
Several Electronic Modulevel Displacer
Transmitters are available for quick shipment, usually within one week after factory
receipt of a purchase order, through the
Expedite Ship Plan (ESP).
To take advantage of ESP, simply match the
color coded model number codes (standard
dimensions apply).
E S P
Expedite
Ship
Plan
Models covered by ESP service are color
coded in the selection data charts.
ESP service may not apply to orders of ten
units or more. Contact your local representative for lead times on larger volume orders,
as well as other products and options.
W A R R A N T Y
All Magnetrol electronic level and flow
controls are warranted free of defects in
materials or workmanship for one full year
from the date of original factory shipment.
If returned within the warranty period; and,
upon factory inspection of the control, the
cause of the claim is determined to be covered under the warranty; then, Magnetrol
will repair or replace the control at no cost
to the purchaser (or owner) other than
transportation.
Magnetrol shall not be liable for misapplication, labor claims, direct or consequential
damage or expense arising from the installation or use of equipment. There are no
other warranties expressed or implied,
except special written warranties covering
some Magnetrol products.
For additional information, see Instruction Manual 48-618.
5300 Belmont Road • Downers Grove, Illinois 60515-4499 • 630-969-4000 • Fax 630-969-9489 • www.magnetrol.com
145 Jardin Drive, Units 1 & 2 • Concord, Ontario Canada L4K 1X7 • 905-738-9600 • Fax 905-738-1306
Heikensstraat 6 • B 9240 Zele, Belgium • 052 45.11.11 • Fax 052 45.09.93
Regent Business Ctr., Jubilee Rd. • Burgess Hill, Sussex RH15 9TL U.K. • 01444-871313 • Fax 01444-871317
Copyright © 2005 Magnetrol International, Incorporated. All rights reserved. Printed in the USA.
Magnetrol and Magnetrol logotype are registered trademarks of Magnetrol International.
Performance specifications are effective with date of issue and are subject to change without notice.
The brand and product names contained within this document are trademarks or registered trademarks of their respective holders.
BULLETIN: 48-118.6
EFFECTIVE: October 2005
SUPERSEDES: April 2004