LSK x5x Conductive Level Sensor Wetted parts in acid-proof, stainless steel and PEEK Compact, food compatible, hygienic design 3A approved, FDA and EHEDG compliant Process temperature -20...140°C Optimised flow geometry LSK350 Millimetre precise switch point Optional PTFE coating Optional Switching module DNGA 230100 Description The conductive level sensor LSK is used for level detection and dry run The LSK provides no current output by itself. protection in conductive liquids. Thus an evaluation module such as DNGA 230 100 is needed to provide an output signal. The LSK measures the resistance between the ground potential and the sensing element covered by the conductive liquid. For a non-conductive tank a 2 rod sensor is needed - one sensor being the reference (ground) terminal. In this application an integrated The tank or pipe side acts as the ground potential. If the tank is made LKP100 output module with a 50 mA output is relevant. of a non-conducting material a ground electrode must be installed. The hygienic installation is ensured by using a hygienic process weldin sleeve e.g. PM 050. The rod electrodes can be shortened to any required length simply by cutting the length. The LSK is well suitable for CIP and SIP processes. www.baumerprocess.com Design and specifications subject to change without notice Data Sheet LSK-2 Page 1 Technical Data - LSKx5x Sensor Amplifier LKP100 Principle Resistance measurement Input Electrode and ground Process connection G1 hygienic Amb. temperature -20...60°C 2...4 electrodes 20...200 cm, see "Ordering Details" Power supply 18...36 Vdc; 10 mA max. (+ load) Insulating material PEEK Sensitivity 200 Ohm; 2 KOhm, 20KOhm (wiring) Switching function Selectable output polarity Damping 0.5 sec. (fixed) Relay output Max. load 50 mA, short circuit protected Monitor LED Dimensions ø44 x 21 mm Electrical connection Cable gland M16 Plast Plug M12 Nickel-plated brass (For 2- or 3 rod models only) Mechanical data Process temperature -20...140°C EMC data Amb. temperature -20...85°C Immunity EN 61326 Housing Stainless steel, W1.4301/AISI 304 Emission EN 61326 Process conn. and rod Stainless steel, W1.4404/AISI 316 L Disposal of product and packing Protection class IP67 According to national laws or by returning to Baumer Media pressure Max. 16 bar Vibrations IEC 68-2-6, GL test2 Powder coating PTFE, Accofal 3G54 Approval 3A Adapters Refer to “Accessories” data sheet Dimensional Drawings - LSKx5x [mm] Electrical Installation ø55 M12plug 3 4 2 1 58 M16 E2 E1 8 2 or 3 rods Gnd E3 AF37 G1 33 3 4 2 1 L 5 6 4 rods E2 E1 E1 E3 4 1 ø4 Gnd E4 E3 1: Brown 2: White M12 plug 3: Blue 4: Black 2 3 E2 www.baumerprocess.com Design and specifications subject to change without notice Gnd Data Sheet LSK-2 Page 2 Ordering Details - LSK x5x LSK x5x xxx xxx (xxx xxx) x Type Uncoated - 2, 3 or 4 rods Coated (PTFE) - 2, 3 or 4 rods Uncoated - 2, 3 or 4 rods Coated (PTFE) - 2, 3 or 4 rods Approval 4´ digit 3A 3A Amplifier Without amplifier With built-in amplifier LKP100, Note {1} 6´ digit Rod # 1 (cm) Specification is mandatory As customers specification (max. 200cm) 7´...9´ digit Rod # 2 (cm) Specification is mandatory As customers specification (max. 200cm) 10´...12´ digit Rod # 3 (cm) Specify if relevant As customers specification (max. 200cm) (13´...15´ digit ) Rod # 4 (cm) Specify if relevant As customers specification (max. 200cm) (16´...18 digit) Gland Cable gland, M16 Plug, M12 (2- or 3 rod models only) 19´ digit 1 2 3 4 0 1 xxx xxx xxx xxx 1 2 Note {1} Only available for a 2-rod sensor mounted in a non-conducting tank, where one rod is used for ground potential. Accessories 3.1 material certificate, type number 5509-227 Double level control module DNGA 230100 (separate data sheet) Refer to the “Accessories” data sheet for a full range of welding parts, adapters, etc. 3A Approval The LSK 35x and LSK 45x are approved by 3A providing it is mounted in a 3A approved counter part and installed according to the guidelines given in the installation manual. The 3A approved products fulfill the FDA demands and follow the EHEDG guidelines regarding design, materials and finishing. Refer to the 3A marked counter parts in the data sheet “Accessories”. PEEK natura Angle > 135 deg. www.baumerprocess.com Design and specifications subject to change without notice Data Sheet LSK-2 Page 3 UK/2007-10-02 This data sheet may only be reproduced in full. www.baumerprocess.com Design and specifications subject to change without notice Data Sheet LSK-2 Page 4