more

CombiTemp TFR5
TM
Room or outdoor temperature sensor
Main features
„„
Sensor in stainless steel, AISI 316L
„„
FlexHousing, Ø80 mm, stainless steel
„„
Wall or pipe mounted
Applications
„„
Room temperature measurement
„„
Outdoor
„„
In cold stores
„„
ATEX applications (pending)
El. connection
Material
Sensor tube dimensions
Material
Cable material for cable sensor
Display, DFON
FlexHousing, Ø80 mm
Stainless steel, AISI 304
Type
Graphically LCD
M16 cable gland
M12 5-pin or M12 8-pin
Plastic
Stainless steel, AISI 303
Front glass
Polycarbonate
Display modes
8 modes, programmable, e.g.
value, bar graph, analogue, tank
illustration, visual data logger
Background
White, green, red, programmable
Measuring range
-9999 ... 99999
Digit height
Max. 22 mm
Accuracy
0.1% @ ambient -10 ... 70°C
Voltage drop
4V ... 6.5V
Output
2 configurables relay output, 60
Vp, 75 mA
Programming
Touch screen or FlexProgrammer
9701
Fixed sensor Ø6 x 100 mm
Cable sensor Ø5.8 x 60 mm
Stainless steel, AISI 316L (1.4404)
High flexible silicone, grey
Sensor element, Pt100 - DIN/EN/IEC 60751
Pt100 1/1 DIN class B
Pt100 1/3 DIN class B
Pt100 1/6 DIN class B
Pt100 1/1 DIN class A
± (0.3 + 0.005xt) °C
± 1/3 x (0.3 + 0.005xt) °C
± 1/6 x (0.3 + 0.005xt) °C
± (0.15 + 0.002xt) °C
Single element
1 x Pt100
Output
Further information can be found in separate data sheet for DFON,
D21.09
Resistance, ceramic terminal
Analogue, built in transmitter
Pt100 signal, 2, 3 or 4 wire
4...20 mA, 4...20 mA HART
Type
LCD
Single element
1 x Pt100
Front Glass
Polycarbonate
2-wire or 4-wire
Measuring range
-200...850°C
Accuracy
±0.3°C
Power supply
1 × AA battery
Protection class
IP 54
Connection
Environment
Media temperature
and ambient temperature
(air temperature)
-40 ... 85°C
-30...80°C with DFON display
-10...70°C with BattTemp display
Protection class
IP67
Humidity
< 98% RH, condensing
Display, BattTemp
Further information can be found in separate data sheet for BattTemp
2400-1
Comply to / Approvals
EMC directive 2004/108/CE in
accordance with EN61326-1/2013
EN/2014-10-16
Comply to
Design and specifications subject to change without notice
Technical specifications
Housing material
www.baumer.com
Data sheet TFR5
Page 1 / 5
CombiTemp TFR5
TM
Room or outdoor temperature sensor
Technical Data
Wall mounting
Cable sensor
Fixed sensor
59
10
PCD Ø 95
100 mm
40
m
m
Ø 91
Ø 110
PCD Ø 95
Available with cable between sensor and
housing in free selectable length
Pipe mounting
Cable sensor
Design and specifications subject to change without notice
DN38
DN51
DN64
40
m
m
Ø 91
70
EN/2014-10-16
Available with cable between sensor
and housing in free selectable length
www.baumer.com
Data sheet TFR5
Page 2 / 5
CombiTemp TFR5
TM
Room or outdoor temperature sensor
Electrical connections
Electrical connections
M12,
M12, 55-wire
fils
M12,
M12, 88-wire
fils
Cable gland
1
Transmitter
1
+24VDC / - 4...20mA
2
- 24VDC / +4...20mA
1
Red clip (FlexProgrammer)
2
Black clip (FlexProgrammer)
2
4...20 mA
RTD
1+2
3+4
1
2
3
4
5
Single Double
Pt100-1
Pt100-1
Pt100 – 1
Pt100 – 1
Pt100 – 2
Pt100 – 2
N.C.
N.C.
11
22
33
44
55
supply,4...20
4...20mA
mA
+- supply,
Commonfor
forrelays
relays
Common
supply,
4...20
mA
- +supply,
4...20
mA
Relay11
Relay
Relay22
Relay
11
22
33
44
55
66
77
88
N.C.
N.C.
supply,4...20
4...20mA
mA
+ -supply,
Relay
Relay1 1
Relay1 1
Relay
Relay2 2
Relay
Relay2 2
Relay
+ supply,
4...20
- supply,
4...20
mAmA
N.C.
N.C.
RTD
Single
White White
Red
Red
Double
White
White Red
Red
Display
+ 4...20
1
N.C. mA
- 4...20
2
N.C. mA
3
Relay
Relay 12
Relay 12
4
Relay
Relay 21
5
Relay
Relay 21
6
Relay
Com 1
Red clip (FlexProgrammer)
Com 2
Black clip (FlexProgrammer)
Dimensionstransmitters
(mm)
Temperature
Bottom connection
Rear connection
Transmitter, type FlexTop 2221 - performance, HART®
Input
Pt100
Input
Pt100 / Pt1000 (universal)
Output
Accuracy
Input
Output
Range
Minimum span
4...20 mA
Output
Accuracy
Input
Output
4...20 mA / HART
Supply
8...35 VDC
Range
Minimum span
-200...850°C
25°C
Programmability
By FlexProgrammer 9701
Supply
8...35 VDC
Programmability
By FlexProgrammer 9701
By HART terminal/modem
<0.25°C
<0.1% signal span (16mA)
-200...850°C
25°C
For further information please see data sheet for FlexTop 2202
<0.1°C
<0.1% signal span (16mA)
For further information please see data sheet for FlexTop 2221
Transmitter, type FlexTop 2211 - Performance
Input
Pt100 / Pt1000 (universal)
Output
Accuracy
Input
Output
4...20 mA
Range
G½A
DIN 2852
Minimum
span
Code 10
Supply
-200...850°C
25°C G½A
Code 11
8...35 VDC
Programmability
By FlexProgrammer 9701
<0.1°C
<0.1% signal span (16mA)
Process connections dimensions (mm)
R½
Code 12
½” NPT
Code 30
Design and specifications subject to change without notice
For further information please see data sheet for FlexTop 2211
Preliminarey data sheet 26.06.2012
Front view
Transmitter, type FlexTop 2202 - Standard
Ø6 mm
Ø8 mm
www.baumer.com
EN/2014-10-16
Ø6 mm
Ø8 mm
17 mm
Data sheet TFR5
Page 3 / 5
CombiTemp TFR5
TM
Room or outdoor temperature sensor
Temperature transmitters - ATEX specifications
Transmitter, type FlexTop 2202 - ATEX
Transmitter, type FlexTop 2221 - ATEX
Approval
Ex ia IIC T5/T6, ATEX II 1G
Ex nA II T5, ATEX II 3G
Approval
Ex ia IIC T5/T6, ATEX II 1G
Ex nA II T5, ATEX II 3G
Supply
8...28 VDC
Supply
8...30 VDC (Ex nA : 12...30 VDC)
Internal inductivity
Internal capacity
Li ≤ 10 µH
Ci ≤ 10 nF
Internal inductivity
Internal capacity
Li ≤ 15 µH
Ci ≤ 5 nF
Temperature class
T1...T5: -40 <Tamb < 85°C
T6:
-40 <Tamb < 50°C
Temperature class
T1...T5: -40 <Tamb < 85°C
T6:
-40 <Tamb < 50°C
U: ≤ 28 VDC
I: ≤ 0.1A
P: ≤ 0.7
Barrier data
U: ≤ 30 VDC
I: ≤ 0.1A
P: ≤ 0.7
Barrier data
Transmitter, type FlexTop 2211 - ATEX
Approval
Ex ia IIC T5/T6, ATEX II 1G
Ex nA II T5, ATEX II 3G
Supply
6.5...30 VDC
Internal inductivity
Internal capacity
Li ≤ 1 5 µH
Ci ≤ 5 nF
Temperature class
T1...T5: -40 <Tamb <85°C
T6:
-40 <Tamb <50°C
U: ≤ 30 VDC
I: ≤ 0.1A
P: ≤ 0.7
Barrier data
DFON display - ATEX specfications
ATEX Gas ia
ATEX Gas nA
Approval Gas Zone 0/1
II 1 G, Ex ia IIC T5 Ga
Voltage drop
UDisp 4.5 ... 6.5 VDC
Temperature class
T1...T5 Zone 0 -20 ... 60 °C
Zone 1/2 -30 ... 65 °C
Internal inductivity
L i
<10 µH
Internal capacity
C i
<15 nF
Barrier data
U i
Ii
Pi
<30 VDC
<0.1 A
<0.75 W
Approval Gas Zone 2
II 3 G, Ex nA II T5
Voltage drop
UDisp Temperature class
T1...T5 -30 < Tamb< 65 °C
4.5 ... 6.5 VDC
Internal inductivity
L i
Internal capacity
C i
<15 nF
Maximum voltage
Umax
<35 VDC
Maximum current
Imax
<0.1 A
<10 µH
Design and specifications subject to change without notice
BattTemp display - ATEX specfications
ATEX Gas ia
Ex II 1G, Ex ia IIC T4/T5
Battery
Energizer Lithium FR6 L91 AA
T1...T4: -10 < Tamb< 70°C
T5:
-10 < Tamb< 50°C
Duracell Alcaline MN1500 LR6 AA
T1...T4: -10 < Tamb< 70°C
T5:
-10 < Tamb< 60°C
EN/2014-10-16
Approval Gas Zone 0/1
www.baumer.com
Data sheet TFR5
Page 4 / 5
CombiTemp TFR5
TM
Room or outdoor temperature sensor
Ordering details
–
TFR5
A
B
C
D
E
1
3
5
9
0
1
3
1
2
4
6
0
1
2
3
4
0
1
3
9
0
1
2
0
1
5
7
A
0000
0000
EN/2014-10-16
Design and specifications subject to change without notice
Model
CombiTempTM TRF5 temperature room sensor
Housing material
FlexHousing Ø80 mm, Stainless steel, AISI 304, wall mount, cable sensor
FlexHousing Ø80 mm, Stainless steel, AISI 304, pipe mount DN38, cable sensor
FlexHousing Ø80 mm, stainless steel, AISI 304, pipe mount DN51, cable sensor
FlexHousing Ø80 mm, stainless steel, AISI 304, pipe mount DN65, cable sensor
FlexHousing Ø80 mm, stainless steel, AISI 304, wall mount, fixed sensor
Electrical connection (output)
M12, 5 pins
M12, 8 pins
Cable gland, M16
No electrical connection - for BattTemp only
Material el. connection
None - for BattTemp only
Plastic
AISI 303
Display
Without display
With display
No relays activated
With display
With activated relays
With BattTemp Battery powered
Transmitter / socket
Flying leads
Ceramic socket
Pt100
Transmitter 2202 4-20 mA
±0.25 °C
Transmitter 2211 4-20 mA
±0.10 °C
®
Transmitter 2221 4-20 mA / HART ±0.10 °C
Safety
Standard
Ex ia IIC T4/T5 1G (Gas) (pending)
Ex nA II T4/T5 3G (Gas) (pending)
Ex ia II 1 G Eex ia IIC, Zone 0, Pt100 output only (pending)
Configuration
No configuration
Configuration of Range
Configuration of Range + Display
Sensor element (DIN/EN/IEC 60751)
None (open cable gland)
1x Pt100 Class 1/1 B
1x Pt100 Class 1/3 B
1x Pt100 Class 1/6 B
1x Pt100 Class 1/1 A
Cable length
None
Cable length between housing and sensor in cm (0100 = 1 meter)
www.baumer.com
Data sheet TFR5
Page 5 / 5