CombiTemp TFR5 TM Room or outdoor temperature sensor Main features Sensor in stainless steel, AISI 316L FlexHousing, Ø80 mm, stainless steel Wall or pipe mounted Applications Room temperature measurement Outdoor In cold stores ATEX applications (pending) El. connection Material Sensor tube dimensions Material Cable material for cable sensor Display, DFON FlexHousing, Ø80 mm Stainless steel, AISI 304 Type Graphically LCD M16 cable gland M12 5-pin or M12 8-pin Plastic Stainless steel, AISI 303 Front glass Polycarbonate Display modes 8 modes, programmable, e.g. value, bar graph, analogue, tank illustration, visual data logger Background White, green, red, programmable Measuring range -9999 ... 99999 Digit height Max. 22 mm Accuracy 0.1% @ ambient -10 ... 70°C Voltage drop 4V ... 6.5V Output 2 configurables relay output, 60 Vp, 75 mA Programming Touch screen or FlexProgrammer 9701 Fixed sensor Ø6 x 100 mm Cable sensor Ø5.8 x 60 mm Stainless steel, AISI 316L (1.4404) High flexible silicone, grey Sensor element, Pt100 - DIN/EN/IEC 60751 Pt100 1/1 DIN class B Pt100 1/3 DIN class B Pt100 1/6 DIN class B Pt100 1/1 DIN class A ± (0.3 + 0.005xt) °C ± 1/3 x (0.3 + 0.005xt) °C ± 1/6 x (0.3 + 0.005xt) °C ± (0.15 + 0.002xt) °C Single element 1 x Pt100 Output Further information can be found in separate data sheet for DFON, D21.09 Resistance, ceramic terminal Analogue, built in transmitter Pt100 signal, 2, 3 or 4 wire 4...20 mA, 4...20 mA HART Type LCD Single element 1 x Pt100 Front Glass Polycarbonate 2-wire or 4-wire Measuring range -200...850°C Accuracy ±0.3°C Power supply 1 × AA battery Protection class IP 54 Connection Environment Media temperature and ambient temperature (air temperature) -40 ... 85°C -30...80°C with DFON display -10...70°C with BattTemp display Protection class IP67 Humidity < 98% RH, condensing Display, BattTemp Further information can be found in separate data sheet for BattTemp 2400-1 Comply to / Approvals EMC directive 2004/108/CE in accordance with EN61326-1/2013 EN/2014-10-16 Comply to Design and specifications subject to change without notice Technical specifications Housing material www.baumer.com Data sheet TFR5 Page 1 / 5 CombiTemp TFR5 TM Room or outdoor temperature sensor Technical Data Wall mounting Cable sensor Fixed sensor 59 10 PCD Ø 95 100 mm 40 m m Ø 91 Ø 110 PCD Ø 95 Available with cable between sensor and housing in free selectable length Pipe mounting Cable sensor Design and specifications subject to change without notice DN38 DN51 DN64 40 m m Ø 91 70 EN/2014-10-16 Available with cable between sensor and housing in free selectable length www.baumer.com Data sheet TFR5 Page 2 / 5 CombiTemp TFR5 TM Room or outdoor temperature sensor Electrical connections Electrical connections M12, M12, 55-wire fils M12, M12, 88-wire fils Cable gland 1 Transmitter 1 +24VDC / - 4...20mA 2 - 24VDC / +4...20mA 1 Red clip (FlexProgrammer) 2 Black clip (FlexProgrammer) 2 4...20 mA RTD 1+2 3+4 1 2 3 4 5 Single Double Pt100-1 Pt100-1 Pt100 – 1 Pt100 – 1 Pt100 – 2 Pt100 – 2 N.C. N.C. 11 22 33 44 55 supply,4...20 4...20mA mA +- supply, Commonfor forrelays relays Common supply, 4...20 mA - +supply, 4...20 mA Relay11 Relay Relay22 Relay 11 22 33 44 55 66 77 88 N.C. N.C. supply,4...20 4...20mA mA + -supply, Relay Relay1 1 Relay1 1 Relay Relay2 2 Relay Relay2 2 Relay + supply, 4...20 - supply, 4...20 mAmA N.C. N.C. RTD Single White White Red Red Double White White Red Red Display + 4...20 1 N.C. mA - 4...20 2 N.C. mA 3 Relay Relay 12 Relay 12 4 Relay Relay 21 5 Relay Relay 21 6 Relay Com 1 Red clip (FlexProgrammer) Com 2 Black clip (FlexProgrammer) Dimensionstransmitters (mm) Temperature Bottom connection Rear connection Transmitter, type FlexTop 2221 - performance, HART® Input Pt100 Input Pt100 / Pt1000 (universal) Output Accuracy Input Output Range Minimum span 4...20 mA Output Accuracy Input Output 4...20 mA / HART Supply 8...35 VDC Range Minimum span -200...850°C 25°C Programmability By FlexProgrammer 9701 Supply 8...35 VDC Programmability By FlexProgrammer 9701 By HART terminal/modem <0.25°C <0.1% signal span (16mA) -200...850°C 25°C For further information please see data sheet for FlexTop 2202 <0.1°C <0.1% signal span (16mA) For further information please see data sheet for FlexTop 2221 Transmitter, type FlexTop 2211 - Performance Input Pt100 / Pt1000 (universal) Output Accuracy Input Output 4...20 mA Range G½A DIN 2852 Minimum span Code 10 Supply -200...850°C 25°C G½A Code 11 8...35 VDC Programmability By FlexProgrammer 9701 <0.1°C <0.1% signal span (16mA) Process connections dimensions (mm) R½ Code 12 ½” NPT Code 30 Design and specifications subject to change without notice For further information please see data sheet for FlexTop 2211 Preliminarey data sheet 26.06.2012 Front view Transmitter, type FlexTop 2202 - Standard Ø6 mm Ø8 mm www.baumer.com EN/2014-10-16 Ø6 mm Ø8 mm 17 mm Data sheet TFR5 Page 3 / 5 CombiTemp TFR5 TM Room or outdoor temperature sensor Temperature transmitters - ATEX specifications Transmitter, type FlexTop 2202 - ATEX Transmitter, type FlexTop 2221 - ATEX Approval Ex ia IIC T5/T6, ATEX II 1G Ex nA II T5, ATEX II 3G Approval Ex ia IIC T5/T6, ATEX II 1G Ex nA II T5, ATEX II 3G Supply 8...28 VDC Supply 8...30 VDC (Ex nA : 12...30 VDC) Internal inductivity Internal capacity Li ≤ 10 µH Ci ≤ 10 nF Internal inductivity Internal capacity Li ≤ 15 µH Ci ≤ 5 nF Temperature class T1...T5: -40 <Tamb < 85°C T6: -40 <Tamb < 50°C Temperature class T1...T5: -40 <Tamb < 85°C T6: -40 <Tamb < 50°C U: ≤ 28 VDC I: ≤ 0.1A P: ≤ 0.7 Barrier data U: ≤ 30 VDC I: ≤ 0.1A P: ≤ 0.7 Barrier data Transmitter, type FlexTop 2211 - ATEX Approval Ex ia IIC T5/T6, ATEX II 1G Ex nA II T5, ATEX II 3G Supply 6.5...30 VDC Internal inductivity Internal capacity Li ≤ 1 5 µH Ci ≤ 5 nF Temperature class T1...T5: -40 <Tamb <85°C T6: -40 <Tamb <50°C U: ≤ 30 VDC I: ≤ 0.1A P: ≤ 0.7 Barrier data DFON display - ATEX specfications ATEX Gas ia ATEX Gas nA Approval Gas Zone 0/1 II 1 G, Ex ia IIC T5 Ga Voltage drop UDisp 4.5 ... 6.5 VDC Temperature class T1...T5 Zone 0 -20 ... 60 °C Zone 1/2 -30 ... 65 °C Internal inductivity L i <10 µH Internal capacity C i <15 nF Barrier data U i Ii Pi <30 VDC <0.1 A <0.75 W Approval Gas Zone 2 II 3 G, Ex nA II T5 Voltage drop UDisp Temperature class T1...T5 -30 < Tamb< 65 °C 4.5 ... 6.5 VDC Internal inductivity L i Internal capacity C i <15 nF Maximum voltage Umax <35 VDC Maximum current Imax <0.1 A <10 µH Design and specifications subject to change without notice BattTemp display - ATEX specfications ATEX Gas ia Ex II 1G, Ex ia IIC T4/T5 Battery Energizer Lithium FR6 L91 AA T1...T4: -10 < Tamb< 70°C T5: -10 < Tamb< 50°C Duracell Alcaline MN1500 LR6 AA T1...T4: -10 < Tamb< 70°C T5: -10 < Tamb< 60°C EN/2014-10-16 Approval Gas Zone 0/1 www.baumer.com Data sheet TFR5 Page 4 / 5 CombiTemp TFR5 TM Room or outdoor temperature sensor Ordering details – TFR5 A B C D E 1 3 5 9 0 1 3 1 2 4 6 0 1 2 3 4 0 1 3 9 0 1 2 0 1 5 7 A 0000 0000 EN/2014-10-16 Design and specifications subject to change without notice Model CombiTempTM TRF5 temperature room sensor Housing material FlexHousing Ø80 mm, Stainless steel, AISI 304, wall mount, cable sensor FlexHousing Ø80 mm, Stainless steel, AISI 304, pipe mount DN38, cable sensor FlexHousing Ø80 mm, stainless steel, AISI 304, pipe mount DN51, cable sensor FlexHousing Ø80 mm, stainless steel, AISI 304, pipe mount DN65, cable sensor FlexHousing Ø80 mm, stainless steel, AISI 304, wall mount, fixed sensor Electrical connection (output) M12, 5 pins M12, 8 pins Cable gland, M16 No electrical connection - for BattTemp only Material el. connection None - for BattTemp only Plastic AISI 303 Display Without display With display No relays activated With display With activated relays With BattTemp Battery powered Transmitter / socket Flying leads Ceramic socket Pt100 Transmitter 2202 4-20 mA ±0.25 °C Transmitter 2211 4-20 mA ±0.10 °C ® Transmitter 2221 4-20 mA / HART ±0.10 °C Safety Standard Ex ia IIC T4/T5 1G (Gas) (pending) Ex nA II T4/T5 3G (Gas) (pending) Ex ia II 1 G Eex ia IIC, Zone 0, Pt100 output only (pending) Configuration No configuration Configuration of Range Configuration of Range + Display Sensor element (DIN/EN/IEC 60751) None (open cable gland) 1x Pt100 Class 1/1 B 1x Pt100 Class 1/3 B 1x Pt100 Class 1/6 B 1x Pt100 Class 1/1 A Cable length None Cable length between housing and sensor in cm (0100 = 1 meter) www.baumer.com Data sheet TFR5 Page 5 / 5