FlexTop 2202 Temperature Transmitter 4...20 mA transmitter for Pt100 sensors 2-, 3- or 4-wire sensors Accuracy better than 0.25°C Sensor offset correction Automatic/configurable cable resistance compensation (2-wire) Sensor error detection 2-way configuration Configurable damping and status indication Engineering unit °C or °F PC datalogging Excellent temperature stability Ex ia IIC T5/T6, ATEX II 1G Description FlexTop 2202 is a 4...20 mA loop-powered transmitter for Pt100 sensors. The Flex-Program has a datalogging facility enabling the user to monitor measuring results or calibrate the measuring setup. Either 2-, 3- or 4-wire sensors can be used. For 2-wire sensors an automatic balancing of the sensor cable resistance is possible with shorted sensor cable. The cable resistance can be manually configured as well. FlexTop 2202 is embedded in silicone which makes it resistant to humid environments. Using a PC, the Windows-based Flex-Program and a FlexProgrammer configuring unit, the following parameters can be configured via the output connectors (2-way communication): TAG no., number of wires, cable resistance, error detection level, measuring range/unit, damping, offset and status indication. www.baumerprocess.com Design and specifications subject to change without notice FlexTop 2202, fitting into the DIN B housing, has a 6 mm center hole for quick sensor replacement. The spring loaded mounting screws ensure a safe fastening even in vibrating environments. Data Sheet 2202-1 Page 1 Technical Data Input Environmental conditions Accuracy Operating temperature-40...85°C Span < 250°C: Span > 250°C: < 0.25°C {2} 0.1% of span Storage temperature-55...90°C Humidity < 98% RH, cond. (IEC 68-2-38) Sample time < 0.7 sec. Vibrations GL, test 2 (IEC 68-2-6) Pt100 Standard IEC/DIN/EN 60 751-2 Long-term test IEC 770 6.3.2 RTD measuring current 0.3 mA, continuously Sensor type 2-, 3- or 4-wires {1} Sensor short detection < -225°C Sensor break detection > 875°C Error detection delay < 10 sec. Compensation for cable error < 0.02°C/Ohm (3-wire) Cable resistance Max. 20 Ohm /wire {1} Measuring range Internal inductivityLi < 10 µH -200...850°C {1} Internal capacity Measuring unit °C or °F {1} Barrier dataU < 28 Vdc ; I < 0.1 A ; P < 0.7 W EMC data Minimum span25°C Generic standards EN 61000-6-3, EN 61000-6-2 Product standards EN 61326 NAMUR NAMUR NE21 Approval Ex ia IIC T5/T6, ATEX II 1G Supply range 8...28 Vdc Ci < 10 nF Protection +/- 35 Vdc Temperature class Suppression 50 and 60 Hz Resolution Mechanical data 14 bit Dimensions ø44 x 19 mm Repeatability < 0.1°C Protection class Housing: IP 40 Ripple immunity IEC 770 6.2.4.2 T1...T5: T6: -40 < Tamb < 85°C -40 < Tamb < 50°C Other data Offset AdjustmentMax. + 10°C {1} Output Temperature drift Typ. 0.003% per °C Max. 0.01% per °C 10 sec. Signal span 4...20 mA, 2-wire Power-on time Accuracy < 0.1% of signal span Supply range 8...35 Vdc Test conditions Ripple immunity 3 Vrms Configuration0...100°C Load equationRL < (Vcc - 8)/23 [kOhm] Amb. temperature 23°C +/- 2°C Power supply 24 VDC Up/Down scaling limits 23 mA/3.5 mA {1} Damping 0...30 sec. {1} Protection Reversed polarity protection According to national laws or by returning to Baumer Resolution 12 bit Notes Disposal of product and packing Effect of variations in supply voltage: {1}Configurable Output current 0.01% per volt {2} TAG No. 15 characters {1} Lower range limit < 100°C Measuring Ranges Type Standard Pt100 DIN/EN/IEC 60751 Lin. resistance Range -200...850°C {2} 0...500 Ohm Min. span 25°C 5 Ohm Accuracy 0.25°C 1 Ohm Ordering details - FlexTop 2202 2202 000x (x) Type 8´ Digit Not configured, standard safety Not configured, Ex ia IIC T5/T6, ATEX II 1G Not configured, Ex nA II T5, ATEX II 3G 1 2 3 Configuration 9´ Digit Configuration according to customer specifications (default is 0...120°C, 3-wire) C www.baumerprocess.com Design and specifications subject to change without notice Data Sheet 2202-1 Page 2 Non-Ex Application 230 VAC Pt100 5 3 4 1 2 4 3 6 2 1 - + - + + 24 VDC 4...20 mA FlexTop 2202 FlexView Power supply Ex Application Zone 0/1 Pt100 230 VAC Safe area 3 4 1 2 4 5 6 3 1 2 - + - + + - 24 VDC 4...20 mA FlexTop 2202 Barrier FlexView Power supply Configuration 2 2 1 Note: Disconnect loop supply before connecting the FlexProgrammer to FlexTop 2202. 1 www.baumerprocess.com Design and specifications subject to change without notice Data Sheet 2202-1 Page 3 Electrical Installation RTD Potentiometer R Resistance R RTD No compensation {3} RTD No compensation {3} Potentiometer Resistance R R UK/2013-02-10 This data sheet may only be reproduced in full. No cable compensation {3} RTD 3-wire cable compensation 3-wire compensation for transfer resistance {4} RTD 3-wire cable compensation Potentiometer Resistance R R 4-wire compensation for transfer resistance {4} 4-wire cable compensation RTD 4-wire cable compensation Notes {3} Configurable compensation for cable resistance {4} Transfer resistance between element and wiper Accessories Dimensional drawing ø44 ø6 26.3 33 ø4 mounting hole. Spring loaded mounting screws. www.baumerprocess.com Design and specifications subject to change without notice [mm] The FlexProgrammer 9701 is a dedicated tool to configure all Baumer configurable products. Type No. 9701-0001 comprises: FlexProgrammer interface unit CD with the FlexProgram software and product drivers (DTM) USB cable Cable with 2 alligator clips Data Sheet 2202-1 Page 4