FlexTop 2204 Temperature Transmitter 4...20 mA transmitter for Pt500 sensors and Resistance input 2-, 3- or 4-wire sensors Accuracy better than 0.25°C (Pt500) Sensor offset correction Automatic/configurable cable resistance compensation (2-wire) Sensor error detection 2-way configuration Configurable damping and status indication Engineering unit °C or °F PC datalogging Excellent temperature stability Ex ia IIC T5/T6, ATEX II 1G Ex nA II T5, ATEX II 3G Description FlexTop 2204 is a 4...20 mA loop-powered transmitter for Pt500 sensors and resistance inputs. The Flex-Program has a datalogging facility enabling the user to monitor measuring results or calibrate the measuring setup. Either 2-, 3- or 4-wire sensors can be used. For 2-wire sensors an automatic balancing of the sensor cable resistance is possible with shorted sensor cable. The cable resistance can be manually configured as well. FlexTop 2204 is embedded in silicone which makes it resistant to humid environments. Using a PC, the Windows-based Flex-Program and a FlexProgrammer configuring unit, the following parameters can be configured via the output connectors (2-way communication): TAG no., number of wires, cable resistance, error detection level, measuring range/unit, damping, offset and status indication. www.baumer.com/process Design and specifications subject to change without notice FlexTop 2204, fitting into the DIN B housing, has a 6 mm center hole for quick sensor replacement. The spring loaded mounting screws ensure a safe fastening even in vibrating environments. Data sheet 2204-1 Page 1 Technical Data Input Environmental conditions Accuracy < 0.25°C {2} Operating temperature -40...85°C Sample time < 0.7 sec. Storage temperature -55...90°C Pt500 Standard IEC/DIN/EN 60 751-2 Humidity < 98% RH, cond. (IEC 68-2-38) RTD measuring current 0.15 mA, continuously Vibrations GL, test 2 (IEC 68-2-6) Sensor type 2-, 3- or 4-wires {1} Long-term test IEC 770 6.3.2 Sensor short detection < -108°C Sensor break detection > 211°C EMC data Error detection delay < 10 sec. Generic standards EN 61000-6-3, EN 61000-6-2 Product standards EN 61326 NAMUR NAMUR NE21 Compensation for cable error < 0.02°C/Ohm (3-wire) {2} Cable resistance Max. 20 Ohm /wire {1} Approval Ex ia IIC T5/T6, ATEX II 1G Measuring unit °C or °F {1} Supply range Protection +/- 35 VDC Internal inductivity Li < 10 µH Suppression 50 and 60 Hz Internal capacity Ci < 10 nF Resolution 14 bit Barrier data U < 28 Vdc ; I < 0.1 A ; P < 0.7 W Repeatability < 0.1°C {2} Ripple immunity IEC 770 6.2.4.2 Temperature class T1...T5: T6: Offset Adjustment Max. + 10°C {1} {2} Mechanical data Output 8...28 VDC -40 < Tamb < 85°C -40 < Tamb < 50°C Dimensions ø44 x 19 mm Housing: IP 40 Signal span 4...20 mA, 2-wire Protection class Accuracy < 0.1% of signal span Other data Supply range 8...35 VDC Ripple immunity 3 Vrms Temperature drift Typ. 0.003% per °C Max. 0.01% per °C Load equation RL < (Vcc - 8)/23 [kOhm] Power-on time 10 sec. Up/Down scaling limits 23 mA/3.5 mA {1} Test conditions Damping 0...30 sec. {1} Configuration 0...100°C Protection Reversed polarity protection Amb. temperature 23°C +/- 2°C Resolution 12 bit Power supply 24 VDC Effect of variations in supply voltage: Output current 0.01% per volt TAG No. 15 characters {1} Disposal of product and packing According to national laws or by returning to Baumer Notes {1} Configurable {2} Pt500 Measuring Ranges Type Standard Pt500 DIN/EN/IEC 60751 Lin. resistance Range -100...160°C {2} 0...1000 Ohm Min. span 25°C 5 Ohm Accuracy 0.25°C 1 Ohm Ordering details - FlexTop 2204 2204 000x (x) Type Not configured, standard safety Not configured, Ex ia IIC T5/T6, ATEX II 1G Not configured, Ex nA II 3G 8´ Digit Configuration Configuration according to customer specifications (default is 0...120°C, 3-wire) 9´ Digit 1 2 3 C Note: The FlexTop 2204 can be supplied in a 30 pcs. packing. Please contact Baumer for further information. www.baumer.com/process Design and specifications subject to change without notice Data sheet 2204-1 Page 2 Non-Ex Application 230 VAC Pt500 5 3 4 1 2 4 3 6 2 1 - + - + + 24 VDC 4...20 mA FlexTop 2204 FlexView Power supply Ex Application Zone 0/1 Pt500 230 VAC Safe area 3 4 1 2 4 5 6 3 1 2 - + - + + - 24 VDC 4...20 mA FlexTop 2204 Barrier FlexView Power supply Configuration 2 2 1 Note: Disconnect loop supply before connecting the FlexProgrammer to FlexTop 2204. 1 www.baumer.com/process Design and specifications subject to change without notice Data sheet 2204-1 Page 3 Electrical Installation RTD Potentiometer R Resistance R RTD RTD No compensation {3} No compensation {3} Potentiometer Resistance R R RTD 3-wire cable compensation 3-wire compensation for transfer resistance {4} RTD Potentiometer 3-wire cable compensation Resistance R R 4-wire compensation for transfer resistance {4} 4-wire cable compensation RTD 4-wire cable compensation EN/2011-11-21 This data sheet may only be reproduced in full. No cable compensation {3} Notes {3} Configurable compensation for cable resistance {4} Transfer resistance between element and wiper Accessories Dimensional drawing ø44 ø6 26.3 [mm] 33 ø4 mounting hole. Spring loaded mounting screws. www.baumer.com/process Design and specifications subject to change without notice The FlexProgrammer 9701 is a dedicated tool to configure all Baumer configurable products. Type No. 9701-0001 comprises: FlexProgrammer Cable with 2 aligator clips Cable from FlexProgrammer to M12 plug for TE2 Cable from FlexProgrammer to M12 Plug for LFFS, LBFS, CPX USB cable CD with the FlexProgram software Data sheet 2204-1 Page 4