Technical Data

FlexTop 2204 Temperature Transmitter
4...20 mA transmitter for Pt500 sensors
and Resistance input
2-, 3- or 4-wire sensors
Accuracy better than 0.25°C (Pt500)
Sensor offset correction
Automatic/configurable cable resistance
compensation (2-wire)
Sensor error detection
2-way configuration
Configurable damping and status indication
Engineering unit °C or °F
PC datalogging
Excellent temperature stability
Ex ia IIC T5/T6, ATEX II 1G
Ex nA II T5, ATEX II 3G
Description
FlexTop 2204 is a 4...20 mA loop-powered transmitter for Pt500 sensors and resistance inputs.
The Flex-Program has a datalogging facility enabling the user to monitor
measuring results or calibrate the measuring setup.
Either 2-, 3- or 4-wire sensors can be used. For 2-wire sensors an
automatic balancing of the sensor cable resistance is possible with
shorted sensor cable. The cable resistance can be manually configured as well.
FlexTop 2204 is embedded in silicone which makes it resistant to humid
environments.
Using a PC, the Windows-based Flex-Program and a FlexProgrammer configuring unit, the following parameters can be configured via
the output connectors (2-way communication): TAG no., number of
wires, cable resistance, error detection level, measuring range/unit,
damping, offset and status indication.
www.baumer.com/process
Design and specifications subject to change without notice
FlexTop 2204, fitting into the DIN B housing, has a 6 mm center hole for
quick sensor replacement. The spring loaded mounting screws ensure a
safe fastening even in vibrating environments.
Data sheet 2204-1
Page 1
Technical Data
Input
Environmental conditions
Accuracy
< 0.25°C {2}
Operating temperature
-40...85°C
Sample time
< 0.7 sec.
Storage temperature
-55...90°C
Pt500 Standard
IEC/DIN/EN 60 751-2
Humidity
< 98% RH, cond. (IEC 68-2-38)
RTD measuring current
0.15 mA, continuously
Vibrations
GL, test 2 (IEC 68-2-6)
Sensor type
2-, 3- or 4-wires {1}
Long-term test
IEC 770 6.3.2
Sensor short detection
< -108°C
Sensor break detection
> 211°C
EMC data
Error detection delay
< 10 sec.
Generic standards
EN 61000-6-3, EN 61000-6-2
Product standards
EN 61326
NAMUR
NAMUR NE21
Compensation for
cable error
< 0.02°C/Ohm (3-wire) {2}
Cable resistance
Max. 20 Ohm /wire {1}
Approval Ex ia IIC T5/T6, ATEX II 1G
Measuring unit
°C or °F {1}
Supply range
Protection
+/- 35 VDC
Internal inductivity
Li < 10 µH
Suppression
50 and 60 Hz
Internal capacity Ci < 10 nF
Resolution
14 bit
Barrier data
U < 28 Vdc ; I < 0.1 A ; P < 0.7 W
Repeatability
< 0.1°C {2}
Ripple immunity
IEC 770 6.2.4.2
Temperature class
T1...T5: T6: Offset Adjustment
Max. + 10°C {1} {2}
Mechanical data
Output
8...28 VDC
-40 < Tamb < 85°C
-40 < Tamb < 50°C
Dimensions
ø44 x 19 mm
Housing: IP 40
Signal span
4...20 mA, 2-wire
Protection class
Accuracy
< 0.1% of signal span
Other data
Supply range
8...35 VDC
Ripple immunity
3 Vrms
Temperature drift
Typ. 0.003% per °C
Max. 0.01% per °C
Load equation
RL < (Vcc - 8)/23 [kOhm]
Power-on time
10 sec.
Up/Down scaling limits
23 mA/3.5 mA {1}
Test conditions
Damping
0...30 sec. {1}
Configuration
0...100°C
Protection
Reversed polarity protection
Amb. temperature
23°C +/- 2°C
Resolution
12 bit
Power supply
24 VDC
Effect of variations in supply voltage:
Output current
0.01% per volt
TAG No.
15 characters {1}
Disposal of product and packing
According to national laws or by returning to Baumer
Notes
{1}
Configurable
{2}
Pt500
Measuring Ranges
Type
Standard
Pt500
DIN/EN/IEC 60751 Lin. resistance
Range
-100...160°C {2}
0...1000 Ohm
Min. span
25°C
5 Ohm
Accuracy
0.25°C
1 Ohm
Ordering details - FlexTop 2204
2204 000x (x)
Type
Not configured, standard safety
Not configured, Ex ia IIC T5/T6, ATEX II 1G
Not configured, Ex nA II 3G
8´ Digit
Configuration
Configuration according to customer specifications (default is 0...120°C, 3-wire)
9´ Digit
1
2
3
C
Note: The FlexTop 2204 can be supplied in a 30 pcs. packing.
Please contact Baumer for further information.
www.baumer.com/process
Design and specifications subject to change without notice
Data sheet 2204-1
Page 2
Non-Ex Application
230 VAC
Pt500
5
3
4
1
2
4
3
6
2
1
-
+
-
+
+
24 VDC
4...20 mA
FlexTop 2204
FlexView
Power supply
Ex Application
Zone 0/1
Pt500
230 VAC
Safe area
3
4
1
2
4
5
6
3
1
2
-
+
-
+
+
-
24 VDC
4...20 mA
FlexTop 2204
Barrier
FlexView
Power supply
Configuration
2
2
1
Note:
Disconnect loop supply before connecting the FlexProgrammer
to FlexTop 2204.
1
www.baumer.com/process
Design and specifications subject to change without notice
Data sheet 2204-1
Page 3
Electrical Installation
RTD
Potentiometer
R
Resistance
R
RTD
RTD
No compensation {3}
No compensation {3}
Potentiometer
Resistance
R
R
RTD
3-wire cable
compensation
3-wire compensation for
transfer resistance {4}
RTD
Potentiometer
3-wire cable
compensation
Resistance
R
R
4-wire compensation for
transfer resistance {4}
4-wire cable
compensation
RTD
4-wire cable
compensation
EN/2011-11-21 This data sheet may only be reproduced in full.
No cable
compensation {3}
Notes
{3} Configurable compensation for cable resistance
{4} Transfer resistance between element and wiper
Accessories
Dimensional drawing
ø44
ø6
26.3
[mm]
33
ø4 mounting hole.
Spring loaded
mounting screws.
www.baumer.com/process
Design and specifications subject to change without notice
The FlexProgrammer 9701 is a dedicated tool to configure all
Baumer configurable products.
Type No. 9701-0001 comprises:
FlexProgrammer
Cable with 2 aligator clips
Cable from FlexProgrammer to M12 plug for TE2
Cable from FlexProgrammer to M12 Plug for LFFS, LBFS, CPX
USB cable
CD with the FlexProgram software
Data sheet 2204-1