EN

Preset counters electronic
2 presets, totalizer and batch counter
Display LED, 5-digits, programmable
NE216
Features
–– Preset counter with two presets
–– Display 5-digits
–– Totalizer, hour counter
–– Operating mode, start count, scaling factor
programmable
–– Connection: Incremental encoder or digital sensors
–– Step and trailing preset programmable
–– Interface RS485
NE216 - LED Preset counter
Technical data - electrical ratings
Technical data - electrical ratings
Voltage supply
24/48 VAC ±10 % (50/60 Hz)
85...265 VAC (50/60 Hz)
12...30 VDC
Standard
DIN EN 61010‑1
Protection class II
Overvoltage category II
Pollution degree 2
Power consumption
5 VA, 5 W
Emitted interference
DIN EN 61000-6-4
Sensor supply
24/48 VAC: 10-26 VDC/60 mA
85...265 VAC:
24 VDC ±20 %/100 mA
12...30 VDC: 9-28 VDC/100 mA
Interference immunity
DIN EN 61000-6-2
Programmable
parameters
Operating modes
Sensor logic
Scaling factor
Count mode
Control inputs
Approval
UL approval / E63076
5-digits
Digit height
7.6 mm
Function
Preset counter
Main counter with 2 presets
Totalizer
Hour counter
Scaling factor
0.0001...9999.99
Count modes
Adding or subtracting
Difference counting A-B
Total (parallel) A+B
Up/Down
A 90° B phase evaluation
Technical data - mechanical design
Ambient temperature
0...+50 °C
Storage temperature
-20...+70 °C
Relative humidity
80 % non-condensing
Connection
Plug-in screw terminal
connector
Core cross-section
1.5 mm²
Protection DIN EN 60529
IP 65 (face with seal)
Operation / keypad
Membrane with softkeys
Counting frequency
3 Hz, 25 Hz, 10 kHz
programmable
Preset
2 presets
Housing type
Built-in housing
Operating modes
Step preset, Trailing preset,
Time meter and hour counter
Dimensions W x H x L
48 x 48 x 100 mm
Mounting depth
100 mm
Data memory
>10 years in EEPROM
Mounting
Clip frame for built-in housing
Reset
Button, electric or automatic
Cutout dimensions
45 x 45 mm (+0.6)
Outputs electronic
Optocoupler
Weight approx.
Outputs relay
Normally open or closed,
programmable
150 g (12-30 VDC/85-265 VAC),
250 g (24/48 VAC)
Materials
Output holding time
0.01...99.99 s
Housing: Makrolon 6485 (PC)
Keypad: Polyester
Interface
RS485
1
www.baumer.com/motion
Subject to modification in technic and design. Errors and omissions excepted.
LED, 7-segment display
Number of digits
14/5/2014
Display
Preset counters electronic
2 presets, totalizer and batch counter
Display LED, 5-digits, programmable
NE216
Part number
Block circuit diagram
AX01
12
Sensor
supply
+
13
-
Voltage
supply
Voltage supply
1 24 / 48 VAC
2 85...265 VAC
3 12...30 VDC
-
1
+
2
Totalizer
Signal input
A
7
B
8
Control input
1
9
2
10
Outputs
1 Relay outputs
2 Electronic outputs
A 90° B
T,R- 14
T,R+ 15
Interface
0 Without interface
1 RS485
Main counter
with 2 presets
start count
scaling factor
Output
3
4
5
Operating
time meter
6
P1
P2
Interface
RS485
Trigger level
Accessories
Comparator inputs
Input circuit
Inputs
PNP- / NPN-logic
Programmable
Input level Low
0...2 VDC
Z 118.033
Input level High
3...40 VDC
Input resistance
3 kΩ
Relay outputs
Output circuit
Switching voltage max.
250 VAC / 110 VDC
Switching current max.
1A
Switching capacity max.
150 VA / 30 W
Relay responding time
5 ms
Electronical outputs
Output circuit
Optocoupler short-circuit proof
Switching voltage max.
40 V
Switching current max.
25 mA
Residual voltage
<1 V
Adaptor plate for screw mount,
face 60 x 75 mm
Z 118.034
Adaptor plate for clip mount,
face 53.2 x 53.2 mm
Z 118.035
Adaptor plate for clip mount,
face 60 x 75 mm
Connection diagram
(OHFWURQLFRXWSXWV
56 6HQVRU
VXSSO\
%
$
&RQWURO 6LJQDO
LQSXW
LQSXW
3
3
2XWSXWV
PD[9
WHUPLQDOWHUPLQDO
±
56 6HQVRU
VXSSO\
%
$
&RQWURO 6LJQDO
LQSXW
LQSXW
3
3
2XWSXWV
PD[9
WHUPLQDOWHUPLQDO
WHUPLQDO
9ROWDJHVXSSO\
75
±
9ROWDJHVXSSO\
75
75
75
5HOD\RXWSXWV
Subject to modification in technic and design. Errors and omissions excepted.
Input level
Adaptor plates
WHUPLQDO
Dimensions
2
www.baumer.com/motion
14/5/2014
NE216.