Preset counters electronic 2 presets, totalizer and batch counter Display LED, 5-digits, programmable NE216 Features –– Preset counter with two presets –– Display 5-digits –– Totalizer, hour counter –– Operating mode, start count, scaling factor programmable –– Connection: Incremental encoder or digital sensors –– Step and trailing preset programmable –– Interface RS485 NE216 - LED Preset counter Technical data - electrical ratings Technical data - electrical ratings Voltage supply 24/48 VAC ±10 % (50/60 Hz) 85...265 VAC (50/60 Hz) 12...30 VDC Standard DIN EN 61010‑1 Protection class II Overvoltage category II Pollution degree 2 Power consumption 5 VA, 5 W Emitted interference DIN EN 61000-6-4 Sensor supply 24/48 VAC: 10-26 VDC/60 mA 85...265 VAC: 24 VDC ±20 %/100 mA 12...30 VDC: 9-28 VDC/100 mA Interference immunity DIN EN 61000-6-2 Programmable parameters Operating modes Sensor logic Scaling factor Count mode Control inputs Approval UL approval / E63076 5-digits Digit height 7.6 mm Function Preset counter Main counter with 2 presets Totalizer Hour counter Scaling factor 0.0001...9999.99 Count modes Adding or subtracting Difference counting A-B Total (parallel) A+B Up/Down A 90° B phase evaluation Technical data - mechanical design Ambient temperature 0...+50 °C Storage temperature -20...+70 °C Relative humidity 80 % non-condensing Connection Plug-in screw terminal connector Core cross-section 1.5 mm² Protection DIN EN 60529 IP 65 (face with seal) Operation / keypad Membrane with softkeys Counting frequency 3 Hz, 25 Hz, 10 kHz programmable Preset 2 presets Housing type Built-in housing Operating modes Step preset, Trailing preset, Time meter and hour counter Dimensions W x H x L 48 x 48 x 100 mm Mounting depth 100 mm Data memory >10 years in EEPROM Mounting Clip frame for built-in housing Reset Button, electric or automatic Cutout dimensions 45 x 45 mm (+0.6) Outputs electronic Optocoupler Weight approx. Outputs relay Normally open or closed, programmable 150 g (12-30 VDC/85-265 VAC), 250 g (24/48 VAC) Materials Output holding time 0.01...99.99 s Housing: Makrolon 6485 (PC) Keypad: Polyester Interface RS485 1 www.baumer.com/motion Subject to modification in technic and design. Errors and omissions excepted. LED, 7-segment display Number of digits 14/5/2014 Display Preset counters electronic 2 presets, totalizer and batch counter Display LED, 5-digits, programmable NE216 Part number Block circuit diagram AX01 12 Sensor supply + 13 - Voltage supply Voltage supply 1 24 / 48 VAC 2 85...265 VAC 3 12...30 VDC - 1 + 2 Totalizer Signal input A 7 B 8 Control input 1 9 2 10 Outputs 1 Relay outputs 2 Electronic outputs A 90° B T,R- 14 T,R+ 15 Interface 0 Without interface 1 RS485 Main counter with 2 presets start count scaling factor Output 3 4 5 Operating time meter 6 P1 P2 Interface RS485 Trigger level Accessories Comparator inputs Input circuit Inputs PNP- / NPN-logic Programmable Input level Low 0...2 VDC Z 118.033 Input level High 3...40 VDC Input resistance 3 kΩ Relay outputs Output circuit Switching voltage max. 250 VAC / 110 VDC Switching current max. 1A Switching capacity max. 150 VA / 30 W Relay responding time 5 ms Electronical outputs Output circuit Optocoupler short-circuit proof Switching voltage max. 40 V Switching current max. 25 mA Residual voltage <1 V Adaptor plate for screw mount, face 60 x 75 mm Z 118.034 Adaptor plate for clip mount, face 53.2 x 53.2 mm Z 118.035 Adaptor plate for clip mount, face 60 x 75 mm Connection diagram (OHFWURQLFRXWSXWV 56 6HQVRU VXSSO\ % $ &RQWURO 6LJQDO LQSXW LQSXW 3 3 2XWSXWV PD[9 WHUPLQDOWHUPLQDO ± 56 6HQVRU VXSSO\ % $ &RQWURO 6LJQDO LQSXW LQSXW 3 3 2XWSXWV PD[9 WHUPLQDOWHUPLQDO WHUPLQDO 9ROWDJHVXSSO\ 75 ± 9ROWDJHVXSSO\ 75 75 75 5HOD\RXWSXWV Subject to modification in technic and design. Errors and omissions excepted. Input level Adaptor plates WHUPLQDO Dimensions 2 www.baumer.com/motion 14/5/2014 NE216.