NE210

Preset counters electronic
1 preset, timer programmable
Display LED, 5-digits, programmable
NE210
Features
–– Preset counter with one preset
–– Display 5-digits
–– Operating mode, start count, scaling factor
programmable
–– Connection: Incremental encoder or digital sensors
–– Time meter with four time ranges
–– Time relay with operation and release delay
–– Programmable as a time counter
NE210 - LED Preset counter
Technical data - electrical ratings
Technical data - electrical ratings
Voltage supply
24/48 VAC ±10 % (50/60 Hz)
85...265 VAC (50/60 Hz)
24 VDC ±10 %
Programmable
parameters
Power consumption
5 VA, 5 W
Sensor supply
24/48 VAC: 12-26 VDC/50 mA
85...265 VAC:
24 VDC ±20 %/100 mA
24 VDC: 24 VDC ±20 %/100 mA
Operating modes
Sensor logic
Scaling factor
Count mode
Time relay function
Approval
UL approval / E63076
Display
LED, 7-segment display
Number of digits
5-digits
Digit height
7.6 mm
Function
Preset counter
Main counter with 1 preset
Scaling factor
0.001...99.999
Count modes
Adding or subtracting
Difference counting A-B
Total (parallel) A+B
Up/Down
A 90° B phase evaluation
0...+50 °C
Storage temperature
-20...+70 °C
Relative humidity
80 % non-condensing
Connection
Plug-in screw terminal
connector
Core cross-section
1.5 mm²
Protection DIN EN 60529
IP 65 (face with seal)
Operation / keypad
Membrane with softkeys
Housing type
Built-in housing
Dimensions W x H x L
48 x 48 x 108 mm
Mounting depth
108 mm
Counting frequency
15 Hz, 10 kHz (set by Dip
switch)
Preset
1 preset
Mounting
Clip frame for built-in housing
Operating modes
Main preset, Time meter / time
relay
Cutout dimensions
45 x 45 mm (+0.6)
Weight approx.
Data memory
>10 years in EEPROM
150 g (24 VDC/85-265 VAC),
260 g (24/48 VAC)
Reset
Button, electric or automatic
Materials
Outputs electronic
NPN / PNP transistor switch
Housing: Makrolon 6485 (PC)
Keypad: Polyester
Outputs relay
Change-over contact, floating
Output holding time
0.01...99.99 s
Standard
DIN EN 61010‑1
Protection class II
Overvoltage category II
Pollution degree 2
Emitted interference
DIN EN 61000-6-4
Interference immunity
DIN EN 61000-6-2
1
www.baumer.com/motion
14/5/2014
Ambient temperature
Subject to modification in technic and design. Errors and omissions excepted.
Technical data - mechanical design
Preset counters electronic
1 preset, timer programmable
Display LED, 5-digits, programmable
NE210
Part number
Block circuit diagram
AXA1
Voltage
supply
Voltage supply
1 24 / 48 VAC
2 85...265 VAC
3 24 VDC
2
+
3
12
13
Signal input
A
7
B
8
Reset
Outputs
Relay output
Relay, signal output PNP
Relay, signal output NPN
Without relay, signal output PNP
Coding for
input logic
NPN Br. 11-13
PNP Br. 11-12
A 90°B
9
Main counter
with 1 preset
start count
scaling factor
Control inputs
PNP- / NPN-logic
Count input
Z 118.033
Adaptor plate for screw mount,
face 60 x 75 mm
Trigger current
9...16 mA
Adaptor plate for clip mount,
face 53.2 x 53.2 mm
Switch-off current
<0.5 mA
Input resistance
1.65 kΩ
Connection diagram
5
Electr. output
9
4
8
7
B
A
Reset
Count
3
Trigger current
5...8 mA
Switch-off current
<0.5 mA
Input resistance
3.3 kΩ
Relay output
Output circuit
Switching voltage max.
250 VAC / 110 VDC
Switching current max.
1A
Switching capacity max.
150 VA / 30 W
Relay responding time
5 ms
Electronical outputs
Output circuit
PNP-switching transistor Open collector
2
1
End contact
Voltage supply
6
NPN Br. 11-13
PNP Br. 11-12
–
Sensor
supply
+
10
electr.
output
Reset input
Adaptor plate for clip mount,
face 60 x 75 mm
11
Relay
output
Trigger level
Adaptor plates
12
5
11
Input circuit
13
4
10
Optocoupler inputs
Z 118.035
+
6
Timer
Time relay
Accessories
Z 118.034
Sensor
supply
-
Switching voltage
24 VDC ±20%
Switching current max.
10 mA (AC)
50 mA (DC)
NPN-switching transistor Open collector
max. 265 V
terminal - terminal /
- terminal
Switching voltage max.
35 V
Switching current max.
50 mA
Dimensions
2
www.baumer.com/motion
Subject to modification in technic and design. Errors and omissions excepted.
1
2
3
4
-
14/5/2014
NE210.0