IVO NE210.043AXA1

Preset counters electronic
1 preset, timer programmable
Display LED, 5-digits, programmable
NE210
Features
–– Preset counter with one preset
–– Display 5-digits
–– Operating mode, start count, scaling factor
programmable
–– Connection: Incremental encoder or digital sensors
–– Time meter with four time ranges
–– Time relay with operation and release delay
–– Programmable as a time counter
NE210 - LED Preset counter
Technical data - electrical ratings
Technical data - electrical ratings
Voltage supply
22...50 VAC (50/60 Hz)
85...265 VAC (50/60 Hz)
24 VDC ±10 %
Programmable
parameters
Power consumption
5 VA, 5 W
Sensor supply
24 VDC ±20 % / 100 mA
Operating modes
Sensor logic
Scaling factor
Count mode
Time relay function
Display
LED, 7-segment display
Approvals
UL/cUL, CE conform
Number of digits
5-digits
Digit height
7.6 mm
Function
Preset counter
Main counter with 1 preset
Operating temperature
0...+50 °C
Storing temperature
-20...+70 °C
Scaling factor
0.001...99.999
Relative humidity
80 % non-condensing
Count modes
Adding or subtracting
A-B (difference counting)
A+B total (parallel counting)
Up/Down
A 90° B phase evaluation
E-connection
Plug-in screw terminals
Core cross-section
1.5 mm²
Protection DIN EN 60529
IP 65 face with seal
Operation / keypad
Membrane with softkeys
Counting frequency
15 Hz, 10 kHz (set by Dip
switch)
Housing type
Built-in housing
Operating modes
Main preset, Time meter / time
relay
Dimensions W x H x L
48 x 48 x 108 mm
Installation depth
108 mm
Data memory
>10 years in EEPROM
Mounting
Clip frame
Reset
Button, electric or automatic
Cutout dimensions
45 x 45 mm (+0.6)
Outputs electronic
NPN / PNP transistor switch
Materials
Outputs relay
Potential-free change-over
contact
Housing: Makrolon 6485 (PC)
Keypad: Polyester
Weight approx.
150 g
Output holding time
0.01...99.99 s
Standard
DIN EN 61010‑1
Protection class II
Overvoltage category II
Pollution degree 2
Emitted interference
DIN EN 61000-6-4
Interference immunity
DIN EN 61000-6-2
www.baumerivo.com
30/10/2008
1
Subject to modification in technic and design. Errors and omissions excepted.
Technical data - mechanical design
Preset counters electronic
1 preset, timer programmable
Display LED, 5-digits, programmable
NE210
Part number
Block circuit diagram
AXA1
Voltage
supply
Voltage supply
1 22...50 VAC
2 85...265 VAC
3 24 VDC
2
+
3
12
13
Signal input
A
7
B
8
Reset
Outputs
Relay output
Relay, signal output PNP
Relay, signal output NPN
Without relay, signal output PNP
Coding for
input logic
NPN Br. 11-13
PNP Br. 11-12
A 90°B
9
Main counter
with 1 preset
start count
scaling factor
5
10
Trigger level
Control inputs
PNP- / NPN-logic
Adaptor plates (page %S)
Count input
Z 118.033
Adaptor plate for screw mount,
face 60 x 75 mm
Trigger current
9...16 mA
Adaptor plate for clip mount,
face 53.2 x 53.2 mm
Switch-off current
<0.5 mA
Input resistance
1.65 kΩ
Reset input
Adaptor plate for clip mount,
face 60 x 75 mm
Connection diagram
11
10
9
6
5
Electr. output
4
7
B
A
Count
Reset
NPN Br. 11-13
PNP Br. 11-12
Sensor
supply
+24V 0V
8
3
Trigger current
5...8 mA
Switch-off current
<0.5 mA
Input resistance
3.3 kΩ
Relay output
Output circuit
Switching voltage max.
250 VAC / 110 VDC
Switching current max.
1A
Switching capacity max.
150 VA / 30 W
Relay responding time
5 ms
Electronical outputs
Output circuit
PNP-switching transistor Open collector
2
1
End contact
Supply voltage
12
electr.
output
11
Input circuit
13
Relay
output
6
Timer
Time relay
Optocoupler inputs
Z 118.035
+
4
Accessories
Z 118.034
Sensor
supply
-
Switching voltage
24 VDC ±20%
Switching current max.
10 mA (AC)
50 mA (DC)
NPN-switching transistor Open collector
max. 265 V
terminal - terminal /
- terminal
Switching voltage max.
35 V
Switching current max.
50 mA
Dimensions
60.8
48
7
108
1-6
48
18.5
2
www.baumerivo.com
Subject to modification in technic and design. Errors and omissions excepted.
1
2
3
4
-
30/10/2008
NE210.0