Click Here to download this file: /data/acdcsupplies/d1u3cs-w-1200-12-hxxc.pdf

www.murata-ps.com
D1U3CS-W-1200-12-HxxC Series
81mm 1U Front End AC-DC Power Supply Converter
PRODUCT OVERVIEW
The D1U3CS-W-1200-12-HxxC series are 80 PLUS Gold efficiency 1200 watt, power factor corrected front end supplies
with a 12V main output and a 5V or 3.3V (20W) standby. They have active current sharing and up to 8 supplies may be
operated in parallel. The supplies may be hot plugged, they recover from overtemperature faults, and have status LEDs
on their front panel in addition to logic and PMBus™ status signals. Their low profile 1U package and >21W/cubic inch
power density make them ideal for delivering reliable, efficient power to servers, workstations, storage systems and
other 12V distributed power systems.
ORDERING GUIDE
Part Number
FEATURES
„ 1200W output power
„ 80 PLUS® Gold efficiency
„ 12V main output
„ 3.3V or 5V standby output of 20W
„ 1U height: 3.20" x 11.00" x 1.57"
„ 21.7 Watts per cubic inch density
„ N+1 redundancy capable, including hot
plugging (up to 8 in parallel)
„ Active current sharing on 12V main output;
ORing FET
„ Overvoltage, overcurrent, overtemperature
protection
„ Internal cooling fan (variable speed)
Power Output
High Line AC
Power Output
Low Line AC
Main
Output
Standby
Output
Airflow
1200W
1200W
1200W
1200W
1000W
1000W
1000W
1000W
12V
12V
12V
12V
3.3V
5V
3.3V
5V
Back to front
Back to front
Front to back
Front to back
Min.
Nom.
Max.
Units
90
47
81
70.5
115/230
50/60
85
74.3
264
63
89
78
8
15
25
Vac
Hz
D1U3CS-W-1200-12-HC4C
D1U3CS-W-1200-12-HA4C
D1U3CS-W-1200-12-HC3C
D1U3CS-W-1200-12-HA3C
INPUT CHARACTERISTICS
Parameter
Conditions
Voltage Operating Range
Frequency
Turn-on Voltage
Turn-off Voltage
Maximum Current at Vin=200Vac
Maximum current at Vin=90Vac
Inrush Current
Power Factor
„ PMBus™ I²C interface with status indicators
Ramp up
Ramp down
1200W
1000W
Cold start between 0 to 200msec
At 230Vac, full load
20% load
Efficiency (230Vac) excluding fan load 50% load
100% load
„ RoHS compliant
OUTPUT VOLTAGE CHARACTERISTICS
Output
Parameter
Voltage
12V
3.3VSB
www.murata-ps.com/en/3d/acdc.html
www.murata-ps.com/en/3d/acdc.html
www.murata-ps.com/en/3d/acdc.html
www.murata-ps.com/en/3d/acdc.html
www.murata-ps.com/en/3d/acdc.html
www.murata-ps.com/en/3d/acdc.html
5VSB
Voltage Set Point Accuracy
Line and Load Regulation
Ripple Voltage & Noise1
Output Current (230Vac)
Output Current (120Vac)
Load Capacitance
Voltage Set Point Accuracy
Line and Load Regulation
Ripple Voltage & Noise1
Output Current
Load Capacitance
Voltage Set Point Accuracy
Line and Load Regulation
Ripple Voltage & Noise1
Output Current
Load Capacitance
Conditions
Vac
Arms
Apk
0.99
88
92
92
Min.
%
Typ.
Max.
12.0
11.4
12.6
120
98.3
81.7
30000
20MHz Bandwidth
0
0
3.3
3.2
20MHz Bandwidth
0
20MHz Bandwidth
0
Vdc
mV p-p
A
μF
Vdc
3.4
100
6
10000
mV p-p
A
μF
5.15
50
4
10000
mV p-p
A
μF
5.0
4.85
Units
Vdc
1
Ripple and noise are measured with 0.1 uF of ceramic capacitance and 10 uF of tantalum capacitance on each of the
power supply outputs. A short coaxial cable with 50ohm scope termination is used.
Available now at
www.murata-ps.com/en/3d/acdc.html
For full details go to
www.murata-ps.com/rohs
CB
Test Certificate
and Test Report
www.murata-ps.com/support
D1U3CS-W-1200-12-HxxC.A03 Page 1 of 6
D1U3CS-W-1200-12-HxxC Series
81mm 1U Front End AC-DC Power Supply Converter
OUTPUT CHARACTERISTICS
Parameter
Conditions
Output Rise Monotonicity
Startup Time
No voltage excursion
AC ramp up
12V, 50-100% load step, 1A/μs di/dt
5VSB, 50-100% load step, 1A/μs di/dt
3.3VSB, 50-100% load step, 1A/μs di/dt
Transient Response
Current sharing accuracy (up to 8 in parallel)
At 100% load
Hot Swap Transients
Holdup Time
All outputs remain in regulation
At full load
Min.
Typ.
Max.
Units
1.5
2.5
300
250
165
s
mV
±7
%
5
%
ms
12
ENVIRONMENTAL CHARACTERISTICS
Parameter
Conditions
Storage Temperature Range
Operating Temperature Range
Operating Humidity
Storage Humidity
Altitude (without derating at 40°C)
Altitude (without derating at 55°C)
Shock
Sinusoidal Vibration
MTBF
Acoustic
Safety Approvals
Input Fuse
Material Flammability
Switching Frequency
Weight
Noncondensing
30G non operating
0.5G, 5 – 500 Hz
Per Telcordia SR-322 M1C1 @40°C
Min.
Typ.
-40
-10
5
5
4000
1800
Max.
Units
70
50
90
95
°C
%
m
500K
55
hrs
dB LpAm
CSA/UL 60950-1-07-2nd Ed.
IEC 60950-1:2005 (2nd Edition) w Am. 1:2009
EN 60950-1:2006 +A11:2009 +A1:2010
CE Marking per LVD DIRECTIVE 2006/95/EC
Power Supply has internal 15A/250V fast blow fuse on the AC line input
UL 94V-0
90KHz for Boost PFC Converter
130KHz for Main Output Converter
3.15lbs (1.43kg)
PROTECTION CHARACTERISTICS
Output
Voltage
12V
3.3VSB
5VSB
Parameter
Conditions
Min.
Typ.
Max.
Units
Overtemperature (intake)
Overvoltage
Overcurrent at 220Vac
Overcurrent at 110Vac
Overvoltage
Overcurrent
Overvoltage
Overcurrent
Autorestart
Latching
Latching
Latching
Latching
Autorecovery
Latching
Autorecovery
57
13.3
108
90
3.9
6.5
5.6
4.4
60
63
14.5
147
102
4.3
9.0
6.0
6.0
°C
V
Min.
Typ.
Max.
Units
A
V
A
V
A
ISOLATION CHARACTERISTICS
Parameter
Insulation Safety Rating / Test Voltage
Isolation
Conditions
Input to Output - Reinforced
Input to Chassis - Basic
Output to Chassis
3000
1500
500
Vrms
Vrms
Vdc
www.murata-ps.com/support
D1U3CS-W-1200-12-HxxC.A03 Page 2 of 6
D1U3CS-W-1200-12-HxxC Series
81mm 1U Front End AC-DC Power Supply Converter
STATUS INDICATORS
Condition
LED Status
Standby - ON; Main output - OFF; AC PRESENT
Standby - ON; Main output - ON
Main output overcurrent, undervoltage, overvoltage
FAN_FAULT; overtemperature; standby overcurrent, standby undervoltage
Blinking green
Solid green
Blinking red
Red
EMISSIONS AND IMMUNITY
Characteristic
Standard
Compliance
Input Current Harmonics
Voltage Fluctuation and Flicker
Conducted Emissions
ESD Immunity
Radiated Field Immunity
Electrical Fast Transients/Burst Immunity
Surge Immunity
RF Conducted Immunity
Magnetic Field Immunity
IEC/EN 61000-3-2
IEC/EN 61000-3-3
FCC 47 CFR Part 15/CISPR 22/EN55022
IEC/EN 61000-4-2
IEC/EN 61000-4-3
IEC/EN 61000-4-4
IEC/EN 61000-4-5
IEC/EN 61000-4-6
IEC/EN 61000-4-8
Voltage dips, interruptions
IEC/EN 61000-4-11
Complies
Complies
Class A, 6dB margin
Level 3 criteria A
Level 3 criteria B
Level 3 criteria B
Level 3 criteria A
Level 3 criteria A
3 A/m criteria B
230Vin, 100% load, Phase 0°, Dip 100% Duration 10ms (A)
230Vin, 50% load, Phase 0°, Dip 100% Duration 20ms (VSB:A, V1:A)
230Vin, 100% load, Phase 0°, Dip 100% Duration > 20ms (VSB, V1:B)
www.murata-ps.com/support
D1U3CS-W-1200-12-HxxC.A03 Page 3 of 6
D1U3CS-W-1200-12-HxxC Series
81mm 1U Front End AC-DC Power Supply Converter
OUTPUT CONNECTOR AND SIGNAL SPECIFICATION
DC and Signal Connector: FCI 51731-057LF
D1
D2
D3
D4
D5
D6
C1
C2
C3
C4
C5
C6
B1
B2
B3
B4
B5
B6
A1
A2
A3
A4
A5
A6
PB1
PB2
PB3
PB4
Description
PB5
PB6
Pin Assignment
Signal Name
Amps per pin
PB1, PB2, PB3
PB4, PB5, PB6
+12V GND
+12V OUT
Main output voltage return
Main output voltage
30
30
A1
PS_ON_L
Input. Internal 10K ohm pull-up (accepts open collector/drain
drive). This signal to be pulled low to turn-on power supply.
N/A
A2
+12VRS_RETURN
Main output remote sense return
N/A
N/A
A3
TEMP_OK
A TTL logic HIGH when operating temperature within allowable
range
A4
PS_SEATED
Power supply is plugged into the system. Internally tied to
ground.
N/A
A5, B5, C5, D5
A6, B6, C6, D6
B1
B2
B3
+VSB
+VSB GND
AC OK
+12VRS
+12V_ISHARE
Standby output voltage
Standby output voltage return
Input AC voltage “OK” signal output
Main output remote sense
Main output active load sharing bus
2.0
2.0
N/A
N/A
N/A
B4
PS_INHIBIT/PS_KILL
This signal is connected to a short pin on the PSU. When left
open operation will be inhibited. When the PSU is inserted into
the system, this pin must be pulled low by the system and will
turn on the PSU only after all inputs have seated.
N/A
C1
C2
SDA
SCL
I2C Data line
I2C Clock line
N/A
N/A
C3
PWR_GD
Power good. Active TTL HIGH when output is within regulation
limits
N/A
C4
D1
D2
D3
D4
FAN_FAIL
A0
A1
S_INT
VSB RS
Fan failure
Address line least significant bit
Address line most significant bit
System interrupt
Standby output remote sense
N/A
N/A
N/A
N/A
N/A
MATING CONNECTORS
Press Fit
Mating Connector
FCI
Straight
TBD
Right Angle
51761-10002406AA
www.murata-ps.com/support
D1U3CS-W-1200-12-HxxC.A03 Page 4 of 6
D1U3CS-W-1200-12-HxxC Series
81mm 1U Front End AC-DC Power Supply Converter
WIRING DIAGRAM FOR OUTPUT
Dotted lines show optional remote sense connections.
Optional remote sense lines can be attached to a load that is a distance
away from the power supply to improve regulation at the load.
+12VRS (Main Output Remote Sense)
B2
PB4-6
+12VRS (Main Output Remote Sense)
+12V OUT
+12V OUT
PB4-6
B2
12V load
D1U3CS
PB1-3
A2
B3
A5,B5,C5,D5
A1
A6,B6,C6,D6
B4
D1U3CS
+12V GND
+12V GND
+12VRS_RETURN
+12V_ISHARE
A2
+12V_ISHARE
B3
PS_ON_L
PS_ON_L
+VSB GND
+12VRS_RETURN
+VSB
+VSB
PB1-3
A5,B5,C5,D5
A1
+VSB load
FET, BJT, wire
or switch (debounced )
to turn on +12V main output
+VSB GND A6,B6,C6,D6
PS_INHIBIT/PS_KILL
PS_INHIBIT/PS_KILL
B4
CURRENT SHARING NOTES
12V Output: Current sharing is achieved using the active current share method. (See wiring diagram for connection details.)
Current sharing can be achieved with or without remote sense connected to the common load.
+VSB outputs can be tied together for redundancy but total combined output power must not exceed 20W. The +VSB output has internal ORing MOSFET for additional redundancy /
internal short protection.
The current share pin B3 is a connection between the two units. It is input and/or output as the voltage on the line controls the current share. A power supply will respond to a change
in this voltage but a power supply can also change the voltage depending on the load drawn from it. On a single unit this would read 8V at 100% load. For two units sharing load then
this should read 4V for perfect current sharing.
Up to 8 units can be paralleled together. Please consult your Murata sales representative if operation with more than 8 units in parallel is needed.
www.murata-ps.com/support
D1U3CS-W-1200-12-HxxC.A03 Page 5 of 6
D1U3CS-W-1200-12-HxxC Series
81mm 1U Front End AC-DC Power Supply Converter
16.50
0.650
MECHANICAL DIMENSIONS
75.00
2.953
Airflow Back to Front
7.04 ±0.80
0.277 ±0.031
39.90 ±0.50
1.571 ±0.020
75.00
2.953
19.50
0.768
83.80 ±0.70
3.299 ±0.028
7.0
0.276
275.50 ±0.70
10.846 ±0.028
279.40 ±0.50
11.000 ±0.020
22.80 ±0.60
0.898 ±0.024
16.20 ±0.60
0.638 ±0.024
75.00
2.953
Power Supply
BACK
17.65
0.695
40.65
1.600
63.65
2.506
Power Supply
FRONT
81.30 ±0.50
3.201 ±0.020
Airflow Front to Back
15.51 ±0.80
0.611 ±0.031
75.00
2.953
AC input connector: IEC 320-C14
Dimensions: 3.20" x 11.00" x 1.571" [81.3mm x 279.4mm x 39.9mm]
OPTIONAL ACCESSORIES
Description
Part Number
12V D1U3CS Output Connector Card
D1U3CS-12-CONC
APPLICATION NOTES
Document Number
Description
Link
ACAN-41
D1U3CS Output Connector Card
www.murata-ps.com/data/apnotes/acan-41.pdf
ACAN-43
D1U3CS-x Communication Protocol
www.murata-ps.com/data/apnotes/acan-43.pdf
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
This product is subject to the following operating requirements
and the Life and Safety Critical Application Sales Policy:
Refer to: http://www.murata-ps.com/requirements/
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2013 Murata Power Solutions, Inc.
www.murata-ps.com/support
D1U3CS-W-1200-12-HxxC.A03 Page 6 of 6
Similar pages
Click Here to download this file: /data/acdcsupplies/d1u2-w-400-12-ha4c.pdf
Click Here to download this file: /data/acdcsupplies/d1u2-d-400-12-ha2c.pdf
Click Here to download this file: /data/acdcsupplies/cps_d1u4-w-1600-hx.pdf
Click Here to download this file: /data/acdcsupplies/cps_c1u-w-1200-12-tx.pdf
Click Here to download this file: /data/acdcsupplies/cps_c1u-w-1200-48-tx.pdf
Click Here to download this file: /data/acdcsupplies/d1u54p-w-1500-12-hxxtc.pdf
Click Here to download this file: /data/acdcsupplies/cps_d1u4-w-1200-hx.pdf
Click Here to download this file: /data/acdcsupplies/d1u86p-w-1600-12-hbxdc.pdf
Click Here to download this file: /data/power/d1u86-d-1600-12-hxxdc.pdf
Click Here to download this file: /data/acdcsupplies/cps_d1u-h-2800-52-hbxc.pdf
Click Here to download this file: /data/acdcsupplies/d1u5cs-h-2825-12-ha4c.pdf
Click Here to download this file: /data/acdcsupplies/d1u54-d-1200-12-hx4pc.pdf
Click Here to download this file: /data/acdcsupplies/cps_d1u-1200-48-hx.pdf
Click Here to download this file: /data/acdcsupplies/cps_d1u-w-1200.pdf
Click Here to download this file: /data/acdcsupplies/d1u4-w-1600-54-hbxc.pdf
Click Here to download this file: /data/acdcsupplies/cps_d1u-w-1600.pdf
Click Here to download this file: /data/acdcsupplies/d2u5t-h3-7000-54-hu4c.pdf
Click Here to download this file: /data/acdcsupplies/d2u5t-h3-5000-380-hu3c.pdf
Click Here to download this file: /data/acdcsupplies/d1u54-d-650-12-hbxc.pdf
Click Here to download this file: /data/acdcsupplies/d1u3cs-w-850-12-hxxc.pdf
Click Here to download this file: /data/acdcsupplies/d1u3cs-d-850-12-hxxc.pdf
MURATA D1U4CS-W-2200-12-HA4C