D2U5T-H3-7000-54-HU4C www.murata-ps.com AC-DC Three Phase Power Converter PRODUCT OVERVIEW The D2U5T-H3-7000-54-HU4C is a High Efficiency 3500/7000 watt, power factor corrected, three phase power converter for 230/480VAC lines with a 54VDC main output and a 5V or 3.3V (20W) selectable standby output. The unit is provided with droop sharing and up to three supplies may be operated in parallel. The supply is hot pluggable. It recovers from over temperature faults, and has status LEDs on the front panel in addition to logic and PMBus status signals. The 2U package and 23.1W/cubic inch power density make them ideal for delivering reliable, efficient power to servers, workstations, storage systems, broadcast transmitters and many other applications. ORDERING GUIDE Model Number D2U5T-H3-7000-54-HU4C Power Output at 480Vac Main Output Standby Output Airflow 7000W 54V 3.3V or 5V (selectable) Back to front FEATURES 7KW (480VAC), 3.5KW (230VAC) Output Power High Efficiency; 96% @ 50% FL 54VDC Main Output 3.3V or 5V Standby Output Dims: 5.1"(W) x 18"(L) x 3.3" (2U) 23.1 watts/cubic inch power density INPUT CHARACTERISTICS Parameter Input Frequency Input Voltage Operating Range Turn-on Voltage (Ramp-up) N+1 redundant (including hot docking) Turn-off Voltage (Ramp-down) Droop sharing on Main Output Maximum Input Current Inrush Current Over-voltage, over-current, over-temperature protections Internal cooling fan Power Factor, Range 1, 230Vac, 60Hz I2C Bus Interface with status indicators RoHS compliant Power Factor, Range 2, 480Vac, 60Hz Two-year warranty Conditions Range 1 Range 2 Range 1 Range 2 Range 1 Range 2 Min 47 180 320 Typ 50/60 Max 63 264 525 30 Units Hz Vac Vac Vac Vac Vac Vac Arms Apk Max Units 176 280 150 260 15 Cold Start 600W 1750W (50% FL) 3500W (100% FL) 600W, 480Vac 3500W (50% FL) 7000W (100% FL) 0.930 0.990 0.995 0.850 0.990 0.995 OVERALL CHARACTERISTICS Parameter Conditions Output Power Efficiency, Range 1 www.murata-ps.com/en/3d/acdc.html www.murata-ps.com/en/3d/acdc.html www.murata-ps.com/en/3d/acdc.html www.murata-ps.com/en/3d/acdc.html www.murata-ps.com/en/3d/acdc.html www.murata-ps.com/en/3d/acdc.html Efficiency, Range 2* Min Typ Range 1 3500 Range 2 7000 700W (20%), 230 Vac 89.0 1750W (50%), 230 Vac 93.5 3500W (100%), 230 Vac 94.0 1400W (20%), 480 Vac 94.2 3500W (50%), 480 Vac 96.0 7000W (100%), 480 Vac 95.5 W % * See graph on page 8. Available now at www.murata-ps.com/en/3d/acdc.html For full details go to www.murata-ps.com/rohs CB Test Certificate and Test Report www.murata-ps.com/support D2U5T-H3-7000-54-HU4C.A02 Page 1 of 8 D2U5T-H3-7000-54-HU4C AC-DC Three Phase Power Converter OUTPUT VOLTAGE CHARACTERISTICS Output Parameter Conditions Range 1 Range 2 @32.4A Range 1 @64.8A Range 2 Min to Max Current, Range 1 Min to Max Current, Range 2 Output Current Voltage Set Point 54V 3.3VSB 5VSB Voltage Droop Line Regulation Ripple Voltage & Noise1 Load Capacitance Voltage Set Point Line and Load Regulation Ripple Voltage & Noise2 Output Current Load Capacitance Voltage Set Point Line and Load Regulation Ripple Voltage & Noise2 Output Current Load Capacitance Min 0 0 Typ Max 64.8 129.6 54 54 1. 5V 3.0V 0.1 0.5 470 5000 3.46 100 6 1000 20MHz Bandwidth 0 20 5.00 4.76 5.24 100 4 1000 20MHz Bandwidth 0 20 Adc Vdc 3.30 3.14 Units % Vp-p μF Vdc mVp-p A μF Vdc mVp-p A μF 1 Ripple and noise are measured with 2.2μF (X7R 100V) ceramic + 180μF (UCC EKY) of electrolytic de-coupling capacitors at the output connector load side. A short coaxial cable with 50Ω scope termination is used. 2 Ripple and noise are measured with 0.1μF of ceramic capacitance and 10 μF of tantalum capacitance across the power supply outputs at the output connector load side. A short coaxial cable with 50Ω scope termination is used. C1 2.2μF X7R 100V T1 + COAX + C2 180μF 63V UCC EKY 54V Output RG587U R1 50Ω SCOPE R2 50Ω SCOPE – T2 + COAX RG587U + VSB – C3 100NF X7R 25V OUTPUT CHARACTERISTICS Parameter Startup Time Transient Response3 Current sharing accuracy (up to 3 in parallel) Hot Swap Transients Holdup Time C4 10μF 10V TANT Conditions AC ramp up 54V, 50-100% load step, 0.1A/μs di/dt 5VSB, 50-100% load step, 1A/μs di/dt 3.3VSB, 50-100% load step, 1A/μs di/dt 54V @100% load All outputs within regulation 54V @100% load VSB @100% Load Min Typ Max 3 2.4 250 250 +/-10 12 100 Units s Vp-p mVp-p mVp-p % ms 3 Minimum output capacitance to be 470μF (low ESR). www.murata-ps.com/support D2U5T-H3-7000-54-HU4C.A02 Page 2 of 8 D2U5T-H3-7000-54-HU4C AC-DC Three Phase Power Converter GENERAL CHARACTERISTICS Parameter Storage Temperature Range Operating Temperature Range Operating Humidity Storage Humidity Altitude (without de-rating at 40°C) Altitude (without de-rating at 50°C) Shock Sinusoidal Vibration MTBF Weight Safety Approvals Input Fuses Material Flammability Airflow Direction PROTECTION CHARACTERISTICS Output Parameter Over-temperature (intake) Over Voltage 54V Over Current Ranges 1 &2 Over Voltage 3.3VSB Over Current Over Voltage 5VSB Over Current Conditions Min -40 0 10 5 Non-condensing Non-condensing 3000 1800 30G non-operating 0.5G, 5 – 500 Hz Calculated per Telcordia SR-332 @40°C Typ Max 70 50 90 90 Units °C °C % % m 250K hrs kg 7 c-CSA-us (CSA 60950-1-07/UL 60950-1, Second Edition) TÜV EN 60950-1:2006+A11+A1+A12 IEC 60950-1:2005 (2nd Ed) + A1:2009, and EN 60950-1:2006/A11:2009/A1:2010/A12:2011 One internal 16A/500V fast blow fuse on each of the three AC line inputs UL 94V0 From Back (connector side) to Front. Optional Front to Back. Conditions Auto-restart Latching, toggling ON/OFF switch unlatches Hiccup mode. Restart every 500msec. Recovers once load drops below OCP level Latching, AC OFF/ON cycling required to unlatch Constant Current Limit (Latches if Output drops below 2V). Hiccup is optional Latching, AC OFF/ON cycling required to unlatch Constant Current Limit (Latches if Output drops below 3V). Hiccup is optional Min 52 58 105 3.9 6.3 5.6 4.2 Typ 55 60 Max 63 62 130 4.3 9 6.0 6 Units °C V % V A V A EMISSIONS AND IMMUNITY Characteristic Standard Input Current Harmonics IEC/EN 61000-3-2 Complies Radiated Emissions (in the application) FCC 47 CFR Parts 15 CISPR 22 EN55022 Class A, 6dB margin ESD Immunity IEC/EN 61000-4-2 Level 3 criteria A Radiated Field Immunity IEC/EN 61000-4-3 Level 3 criteria B Electrical Fast Transients/Burst Immunity IEC/EN 61000-4-4 Level 3 criteria A Surge Immunity IEC/EN 61000-4-5 Level 3 criteria A RF Conducted Immunity IEC/EN 61000-4-6 Level 3 criteria A Magnetic Field Immunity IEC/EN 61000-4-8 3 A/m criteria B IEC/EN 61000-4-11 400Vrms Input Voltage 54V & VSB Outputs, Performance a) 100% load, Phase 0°, Dip 100% Duration 10ms 50% load, Phase 0°, Dip 100% Duration 20ms 54V & VSB Outputs, Performance b) 100% load, Phase 0°, Dip 100% Duration >10ms Any Load, Phase 0°, Dip 100% Duration >100ms Any valid Input Voltage, any load 54V & VSB Outputs, Performance a) Dip 30% on single Phase or Line, Duration 100ms 54V & VSB Outputs, Performance b) Dip 30% on single Phase or Line, Duration >100ms Conducted Emissions Voltage Dips & Interruptions Voltage imbalance (Circuit will stop when input voltage imbalance exceeds 8% for more than 100ms. Unit will restart when imbalance returns below 8%) Compliance Class A, 6dB margin www.murata-ps.com/support D2U5T-H3-7000-54-HU4C.A02 Page 3 of 8 D2U5T-H3-7000-54-HU4C AC-DC Three Phase Power Converter ISOLATION CHARACTERISTICS Parameter Insulation Safety Rating/Test Voltage Conditions Min Input to Output – Reinforced 3000 Typ Max Vrms Units Input to Chassis – Basic 1500 Vrms Output to Chassis – Functional 500 Vdc STATUS INDICATORS (LEDs) Status Indicators Input OK (Green) Output OK (Green) Fault5 (Yellow) AC present and within the regulation range; Standby - ON; Main Output – OFF Solid Green Blinking Off Off Off Off Off Off Off Off Solid Green Solid Green Off Solid Green Solid Green On No Change No Change Blinking 1Hz Blinking Green at 1Hz rate (0.5s on, 0.5s off) Blinking Green at 1Hz rate (0.5s on, 0.5s off) AC present, but its level is not within the required regulation range When hot-unplugging the power supply from a power shelf4 AC input voltage is not present AC present and within the regulation range; Standby – ON, Main Output – ON and both within the regulation range AC present and within the regulation range; Standby - ON; Main Output - ON; power supply is in a power limit or in an overcurrent condition. Any warning Levels (Input UV/OV, OC, Inlet Temp, Output and STBY OV/UV, OC, OTP, FAN) Any Fault Levels (Input UV/OV, OC, Inlet Temp, Output and STBY OV/UV, OC, OTP, FAN) Depends on PS Status Depends on PS Status On 4 The Input OK LED blinks to indicate that there is still energy inside the power supply until the input bulk capacitors are completely discharged or the housekeeping circuit is shut down. 5 The Fault LED and PS Fault signal shall be turned on to indicate that there is one or more of the following internal faults currently detected inside the power supply: • VSB out of range • Output stage OT • Fan fault • ORING fault (Output voltage less than bus voltage) • OC shutdown • OT shutdown • OV shutdown • Input stage OT • Fault induced shutdown occurred • Thermal sensor fault • Vout out of range • PFC Boost Vbulk fault As soon as all of the above faults are removed and the power supply operates normally, the Fault LED and PS Fault signal shall be turned off. LED Definition: Three LEDs shall be located on the front faceplate, and these are: LED Status Input OK = ON Output OK = ON Fault = ON www.murata-ps.com/support D2U5T-H3-7000-54-HU4C.A02 Page 4 of 8 D2U5T-H3-7000-54-HU4C AC-DC Three Phase Power Converter Control Signals Signal (I/O) Description PS_ON_H (Input) Internal 10K pull-up resistor to internal VDD6 • Leaving signal pin open = Main Output ON • Tying signal pin to GND = Main Output OFF PS_KILL (Input) Short pin; internal 10K pull-up resistor to internal VDD6 • Leaving signal pin open = All Outputs off • Tying signal pin to GND = All Outputs enabled Internal 10K pull-up resistor to internal VDD6 • PSU Fault Status Internal 10K pull-up resistor to internal VDD6 • Main Output Status OK PS_FAULT_L (Output) PWR_GOOD_H (Output) I_SHARE (Input/output -bus) Analog representation of main output current; can be left open if not used STBY_SEL_IN (Input) Internal 10K pull-up resistor to internal VDD6 • Leaving signal pin open = +5V STBY • Tying signal pin to GND = 3V3STBY Internal 10K pull-up resistor to internal VDD6 • AC OK Status Internal 10K pull-up resistor to internal VDD6 SMB_ALERT_L (Output) • SMB Alert signal output 6 VDD depends on Standby Voltage selection of either 3.3V or 5V. AC_OK_H (Output) AC POWER CONNECTOR Header Positronic PLS5W5F1000 Position Part Number 1 Positronic: FS612N2 2 Positronic: FS612N2 Contacts 3 4 Positronic: FS612N2 5 Positronic: FS612N2 Function Safety Ground AC Line Voltage Ph 1 Not fitted AC Line Voltage Ph 2 AC Line Voltage Ph 3 1.795 [45.59] 1 2 3 0.802 [20.36] 4 5 0.401 [10.18] 2X Ø0.100 [Ø2.54] THRU 1.295 [32.89] www.murata-ps.com/support D2U5T-H3-7000-54-HU4C.A02 Page 5 of 8 D2U5T-H3-7000-54-HU4C AC-DC Three Phase Power Converter CUSTOMER AC POWER CONNECTOR Header Positronic PLS5W5M1000 Position Part Number Function 1 Positronic: MS612N Safety Ground 2 Positronic: MS612N-228.2 AC Line Voltage Ph 1 3 Not fitted Contacts 4 Positronic: MS612N-228.2 AC Line Voltage Ph 2 5 Positronic: MS612N-228.2 AC Line Voltage Ph 3 NOTE: The Safety Ground MUST mate first. The Customer SHALL use the longer pin specified for position 1 and the shorter pins specified for positions 2, 4 and 5. 1.795±0.020 [45.59±0.51] 3 2 1 5 0.802 [20.36] 4 0.401 [10.18] 2X Ø0.100 [Ø2.54] THRU 1.295 [32.89] OUTPUT CONNECTOR Connector: FCI Power Blade. Right Angle Header, 24 Signal Pins & 12 Power Blades. Part # 51939-486LF Mating connector option #1: FCI Power Blade. Right Angle Connector, 24 Signal Pins & 12 Power Blades. Part # 51915-132 Mating connector option #2: FCI Power Blade. Straight Connector, 24 Signal Pins & 12 Power Blades. Part # 51940-323 ROWS POWER E1 D C B A SIGNAL P1 P2 P3 P4 P5 P6 P7 P8 P9 P10 P11 P12 PA 1 2 3 4 5 6 E2 UUUUHH T T T GG PA T SSSSFF RRRRE E www.murata-ps.com/support D2U5T-H3-7000-54-HU4C.A02 Page 6 of 8 D2U5T-H3-7000-54-HU4C AC-DC Three Phase Power Converter OUTPUT CONNECTOR & SIGNAL PIN ASSIGNMENT Connector: FCI Power Blade Part # 51939-486LF Power Blade Number P12 A2 A3 A4 A5 A6 B1 B2 B3 B4 Signal +VOUT +VOUT +VOUT -VOUT -VOUT -VOUT -VOUT -VOUT -VOUT +VOUT +VOUT +VOUT Signal A1 PS_FAULT_L A0 VSB_RTN SCL VOUT_SENSE+ A2 PS_ON_H +VSB VSB_RTN B5 PS_KILL B6 C1 C2 C3 C4 C5 N/A STBY_SEL_IN AC_OK_H +VSB VSB_RTN SDA VOUT_SENSESMB_ALERT_L PWR_GOOD_H +VSB VSB_RTN VSB_RTN VSB_RTN P11 P10 P9 P8 P7 P6 P5 P4 P3 P2 P1 Signal Pin Number A1 C6 D1 D2 D3 D4 D5 D6 Function 54Vdc 54Vdc 54Vdc 54Vdc Return 54Vdc Return 54Vdc Return 54Vdc Return 54Vdc Return 54Vdc Return Signal Direction Output Output Output Output Output Output Output Output 54Vdc Output Output 54Vdc 54Vdc Function I2C Address Bit 1 Signal PSU Fault Status I2C Address Bit 0 Signal VSTBY_RTN I2C Clock Signal VOUT_SENSE+ I2C Address Bit 2 Signal Enable PSU +3.3V/5V STBY Out VSTBY_RTN Enable PSU Shortest pin of the connector Reserved No User Connection Selects +3V3 or +5VSTBY AC(DC) OK Status +3.3V/5V STBY Out VSTBY_RTN I2C Data Signal VOUT_SENSESMB Alert signal output Power OK Status +3.3V/5V STBY Out VSTBY_RTN VSTBY_RTN VSTBY_RTN Output Output Signal Direction Input Output Input Output Bi-Directional Input Input Input Output Output Input Output Input Output Output Output Bi-Directional Input Output Output Output Output Output Output www.murata-ps.com/support D2U5T-H3-7000-54-HU4C.A02 Page 7 of 8 D2U5T-H3-7000-54-HU4C AC-DC Three Phase Power Converter MECHANICAL DIMENSIONS Dimensions: 5.1" x 18"x 3.3" [129.5mm x 455.9mm x 84.5mm] EFFICIENCY 97 96 Efficiency (%) 95 94 93 480VAC 92 91 90 0 10 20 30 40 50 60 70 80 90 100 Full Load (%) OPTIONAL ACCESSORIES Description Part Number 54V D2U5T Output Connector Card D2U5T-54-CONC APPLICATION NOTES Document Number Description Link ACAN-55 D2U5T PMBusTM Communication Protocol http://power.murata.com/datasheet?/data/apnotes/acan-55.pdf ACAN-56 D2U5T Output Interface Connector Card http://power.murata.com/datasheet?/data/apnotes/acan-56.pdf Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. ISO 9001 and 14001 REGISTERED This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: http://www.murata-ps.com/requirements/ Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2015 Murata Power Solutions, Inc. www.murata-ps.com/support D2U5T-H3-7000-54-HU4C.A02 Page 8 of 8