INTERSIL EL4584CN

EL4584
®
Data Sheet
July 25, 2005
Horizontal Genlock, 4FSC
Features
The EL4584 is a PLL (Phase Lock Loop) sub system,
designed for video applications but also suitable for general
purpose use up to 36MHz. In video applications, this device
generates a TTL/CMOS compatible Pixel Clock (CLK OUT)
which is a multiple of the TV horizontal scan rate and phase
locked to it.
• 36MHz, general purpose PLL
The reference signal is a horizontal sync signal, TTL/CMOS
format, which can be easily derived from an analog
composite video signal with the EL4583 Sync Separator. An
input signal to “coast” is provided for applications were
periodic disturbances are present in the reference video
timing such as VTR head switching. The Lock detector
output indicates correct lock.
The divider ratio is four ratios for NTSC and four similar
ratios for the PAL video timing standards, by external
selection of three control pins. These four ratios have been
selected for common video applications including 4FSC,
3FSC, 13.5MHz (CCIR 601 format) and square picture
elements used in some workstation graphics. To generate
8FSC, 6FSC, 27MHz (CCIR 601 format) etc. use the
EL4585, which includes an additional divide-by-two stage.
For applications where these frequencies are inappropriate
or for general purpose PLL applications the internal divider
can be bypassed and an external divider chain used.
FREQUENCIES AND DIVISORS
FUNCTION
Divisor
PAL FOSC (MHz)
Divisor
NTSC FOSC MHz)
3FSC
CCIR 601
(NOTE 1) (NOTE 2)
SQUARE
(NOTE 3)
4FSC
851
864
944
1135
13.301
13.5
14.75
17.734
682
858
780
910
10.738
13.5
12.273
14.318
NOTES:
1. 3FSC numbers do not yield integer divisors.
2. CCIR 601 Divisors yield 720 pixels in the portion of each line for
NTSC and PAL.
3. Square pixels format gives 640 pixels for NTSC and 768 pixels
for PAL in the active portion.
FN7174.2
• 4FSC based timing (use the EL4585 for 8FSC)
• Compatible with EL4583 sync separator
• VCXO, Xtal, or LC tank oscillator
• < 2ns jitter (VCXO)
• User controlled PLL capture and lock
• Compatible with NTSC and PAL TV formats
• 8 pre-programmed TV scan rate clock divisors
• Selectable external divide for custom ratios
• Single 5V, low current operation
• Pb-Free plus anneal available (RoHS compliant)
Applications
• Pixel clock regeneration
• Video compression engine (MPEG) clock generator
• Video capture or digitization
• PIP (Picture in Picture) timing generator
• Text or graphics overlay timing
Ordering Information
PART NUMBER
PACKAGE
TAPE &
REEL
PKG. DWG.
#
EL4584CN
16-Pin PDIP
-
MDP0031
EL4584CS
16-Pin SO (0.150”)
-
MDP0027
EL4584CS-T7
16-Pin SO (0.150”)
7”
MDP0027
EL4584CS-T13
16-Pin SO (0.150”)
13”
MDP0027
EL4584CSZ
(See Note)
16-Pin SO (0.150”)
(Pb-free)
-
MDP0027
EL4584CSZ-T7
(See Note)
16-Pin SO (0.150”)
(Pb-free)
7”
MDP0027
EL4584CSZ-T13 16-Pin SO (0.150”)
(See Note)
(Pb-free)
13”
MDP0027
*For 6FSC and 8FSC clock frequencies, see EL4585 datasheet.
NOTE: Intersil Pb-free plus anneal products employ special Pb-free material
sets; molding compounds/die attach materials and 100% matte tin plate
termination finish, which are RoHS compliant and compatible with both SnPb
and Pb-free soldering operations. Intersil Pb-free products are MSL classified
at Pb-free peak reflow temperatures that meet or exceed the Pb-free
requirements of IPC/JEDEC J STD-020.
Demo Board
A demo PCB is available for this product.
1
CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures.
1-888-INTERSIL or 1-888-468-3774 | Intersil (and design) is a registered trademark of Intersil Americas Inc.
Copyright Intersil Americas Inc.2003-2005. All Rights Reserved
All other trademarks mentioned are the property of their respective owners.
EL4584
Pinout
EL4584
(16-PIN SO, PDIP)
TOP VIEW
2
FN7174.2
July 25, 2005
EL4584
Absolute Maximum Ratings (TA = 25°C)
VCC Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7V
Operating Junction Temperature . . . . . . . . . . . . . . . . . . . . . . . 125°C
Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . .-65°C to +150°C
Power Dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .400mW
Oscillator Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36MHz
Pin Voltages. . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.5V to VCC +0.5V
Operating Ambient Temperature Range . . . . . . . . . .-40°C to +85°C
CAUTION: Stresses above those listed in “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress only rating and operation of the
device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
IMPORTANT NOTE: All parameters having Min/Max specifications are guaranteed. Typical values are for information purposes only. Unless otherwise noted, all tests
are at the specified temperature and are pulsed tests, therefore: TJ = TC = TA
DC Electrical Specifications
VDD = 5V, TA = 25°C unless otherwise noted
PARAMETER
CONDITIONS
IDD
MIN
VDD = 5V (Note 1)
TYP
MAX
UNIT
2
4
mA
1.5
V
VIL Input Low Voltage
VIH Input High Voltage
3.5
V
-100
nA
IIL Input Low Current
All inputs except COAST, VIN = 1.5V
IIH Input High Current
All inputs except COAST, VIN = 3.5V
IIL Input Low Current
COAST pin, VIN = 1.5V
IIH Input High Current
COAST pin, VIN = 3.5V
VOL Output Low Voltage
Lock Det, IOL = 1.6mA
VOH Output High Voltage
Lock Det, IOH = -1.6mA
VOL Output Low Voltage
CLK, IOL = 3.2mA
VOH Output High Voltage
CLK, IOH = -3.2mA
VOL Output Low Voltage
OSC Out, IOL = 200µA
VOH Output High Voltage
OSC Out, IOH = -200µA
2.4
IOL Output Low Current
Filter Out, VOUT = 2.5V
200
IOH Output High Current
Filter Out, VOUT = 2.5V
IOL/IOH Current Ratio
Filter Out, VOUT = 2.5V
ILEAK Filter Out
Coast Mode, VDD > VOUT > 0V
100
-100
-60
60
nA
µA
100
µA
0.4
V
2.4
V
0.4
2.4
V
V
0.4
V
V
300
µA
-300
-200
µA
1.05
1.0
0.95
-100
±1
100
nA
MIN
TYP
MAX
UNIT
NOTE:
1. All inputs to 0V, COAST floating.
AC Electrical Specifications
VDD = 5V, TA = 25°C unless otherwise noted
PARAMETER
CONDITIONS
VCO Gain @ 20MHz
Test circuit 1
15.5
HSYNC S/N Ratio
VDD = 5V (Note 1)
Jitter
VCXO oscillator
1
ns
Jitter
LC oscillator (Typ)
10
ns
35
dB
dB
NOTE:
1. Noisy video signal input to EL4583, HSYNC input to EL4584. Test for positive signal lock.
3
FN7174.2
July 25, 2005
EL4584
Pin Descriptions
PIN NUMBER
PIN NAME
FUNCTION
1, 2, 16
PROG A,B,C
3
OSC/VCO OUT
4
VDD (A)
5
OSC/VCO IN
6
VSS (A)
7
CHARGE PUMP
OUT
Connect to loop filter. If the HSYNC phase is leading or HSYNC frequency > CLK ÷ N, current is pumped
into the filter capacitor to increase VCO frequency. If HSYNC phase is lagging or frequency < CLK ÷ N,
current is pumped out of the filter capacitor to decrease VCO frequency. During coast mode or when
locked, charge pump goes to a high impedance state.
8
DIV SELECT
Divide select input. When high, the internal divider is enabled and EXT DIV becomes a test pin, outputting
CLK ÷ N. When low, the internal divider is disabled and EXT DIV is an input from an external ÷ N.
9
COAST
10
HSYNC IN
11
VDD (D)
12
LOCK DET
13
EXT DIV
External Divide input when DIV SEL is low, internal ÷N output when DIV SEL is high.
14
VSS (D)
Ground for digital, I/O circuits.
15
CLK OUT
Digital inputs to select ÷ N value for internal counter. See table below for values.
Output of internal inverter/oscillator. Connect to external crystal or LC tank VCO circuit.
Analog positive supply for oscillator, PLL circuits.
Input from external VCO.
Analog ground for oscillator, PLL circuits.
Tri-state logic input. Low (<1/3*VCC) = normal mode, Hi Z (or 1/3 to 2/3*VCC) = fast lock mode,
High (>2/3*VCC) = coast mode.
Horizontal sync pulse (CMOS level) input.
Positive supply for digital, I/O circuits.
Lock Detect output. Low level when PLL is locked. Pulses high when out of lock.
Buffered output of the VCO.
TABLE 1. VCO DIVISORS
PROG A (PIN 16)
PROG B (PIN 1)
PROG C (PIN 2)
DIV VALUE (N)
0
0
0
851
0
0
1
864
0
1
0
944
0
1
1
1135
1
0
0
682
1
0
1
858
1
1
0
780
1
1
1
910
4
FN7174.2
July 25, 2005
EL4584
Timing Diagrams
Falling edge of HSYNC + 110ns locks
to rising edge of Ext Div signal.
FIGURE 1. PLL LOCKED CONDITION (PHASE ERROR = 0)
θE = (Tθ/TH) × 360°
TH = HSYNC period
Tθ = phase error period
FIGURE 2. OUT OF LOCK CONDITION
FIGURE 3. TEST CIRCUIT 1
5
FN7174.2
July 25, 2005
EL4584
Typical Performance Curves
IDD vs FOSC
EL4584 OSC GAIN @ 20MHz vs TEMPERATURE
OSC GAIN vs FOSC
TYPICAL VARACTOR
CHARGE PUMP DUTY CYCLE vs θE
Package Power Dissipation vs Ambient Temperature
JEDEC JESD51-7 High Effective Thermal Conductivity
Test Board
1.8
2
1.6
1.8
POWER DISSIPATION (W)
POWER DISSIPATION (W)
Package Power Dissipation vs Ambient Temperature
JEDEC JESD51-3 Low Effective Thermal Conductivity
Test Board
1.4
1.23W
1.2
PDIP16
θJA=81°C/W
1 0.91W
0.8
0.6
SO16 (0.150”)
θJA=110°C/W
0.4
0.2
1.6
1.43W
1.4
1.25W
PDIP16
θJA=70°C/W
1.2
1
0.8
SO16 (0.150”)
θJA=80°C/W
0.6
0.4
0.2
0
0
0
25
50
75 85 100
125
AMBIENT TEMPERATURE (°C)
6
150
0
25
50
75
100
125
150
AMBIENT TEMPERATURE (°C)
FN7174.2
July 25, 2005
EL4584
Block Diagram
Description Of Operation
The horizontal sync signal (CMOS level, falling leading
edge) is input to HSYNC input (pin 10). This signal is delayed
about 110ns, the falling edge of which becomes the
reference to which the clock output will be locked. (See
timing diagrams.) The clock is generated by the signal on pin
5, OSC in. There are 2 general types of VCO that can be
used with the EL4584, LC and crystal controlled.
Additionally, each type can be either built up using discrete
components, including a varactor as the frequency
controlling element, or complete, self contained modules can
be purchased with everything inside a metal can. The
modules are very forgiving of PCB layout, but cost more than
discrete solutions. The VCO or VCXO is used to generate
the clock. An LC tank resonator has greater “pull” than a
crystal controlled circuit, but will also be more likely to drift
over time, and thus will generate more jitter. The “pullability”
of the circuit refers to the ability to “pull” the frequency of
oscillation away from its center frequency by modulating the
voltage on the control pin of a VCO module or varactor, and
is a function of the slope and range of the capacitancevoltage curve of the varactor or VCO module used. The VCO
signal is sent to a divide by N counter, and to the CLK out
pin. The divisor N is determined by the state of pins 1,2, and
16 and is described in table 1 above. The divided signal is
sent, along with the delayed Hsync input, to the
phase/frequency detector, which compares the two signals
for phase and frequency differences. Any phase difference is
converted to a current at the charge pump output FILTER
(pin 7). A VCO with positive frequency deviation with control
voltage must be used. Varactors have negative capacitance
slope with voltage, resulting in positive frequency deviation
with control voltage for the oscillators in figures 10 and 11.
VCO
The VCO should be tuned so its frequency of oscillation is
very close to the required clock output frequency when the
voltage on the varactor is 2.5 volts. VCXO and VCO
7
modules are already tuned to the desired frequency, so this
step is not necessary if using one of these units. The range
of the charge pump output (pin 7) is 0 to 5 volts and it can
source or sink a maximum of about 300µA, so all frequency
control must be accomplished with variable capacitance
from the varactor within this range. Crystal oscillators are
more stable than LC oscillators, which translates into lower
jitter, but LC oscillators can be pulled from their mid-point
values further, resulting in a greater capture and locking
range. If the incoming horizontal sync signal is known to be
very stable, then a crystal oscillator circuit can be used. If the
HSYNC signal experiences frequency variations of greater
than about 300ppm, an LC oscillator should be considered,
as crystal oscillators are very difficult to pull this far. When
HSYNC input frequency is greater than CLK frequency ÷ N,
charge pump output (pin 7) sources current into the filter
capacitor, increasing the voltage across the varactor, which
lowers its capacitance, thus tending to increase VCO
frequency. Conversely, filter output pulls current from the
filter capacitor when HSYNC frequency is less than CLK ÷ N,
forcing the VCO frequency lower.
Loop Filter
The loop filter controls how fast the VCO will respond to a
change in filter output stimulus. Its components should be
chosen so that fast lock can be achieved, yet with a
minimum of VCO “hunting”, preferably in one to two
oscillations of charge pump output, assuming the VCO
frequency starts within capture range. If the filter is underdamped, the VCO will over and under-shoot the desired
operating point many times before a stable lock takes place.
It is possible to under-damp the filter so much that the loop
itself oscillates, and VCO lock is never achieved. If the filter
is over-damped, the VCO response time will be excessive
and many cycles will be required for a lock condition. Overdamping is also characterized by an easily unlocked system
because the filter can’t respond fast enough to perturbations
in VCO frequency. A severely over damped system will
seem to endlessly oscillate, like a very large mass at the end
FN7174.2
July 25, 2005
EL4584
of a long pendulum. Due to parasitic effects of PCB traces
and component variables, it will take some trial and error
experimentation to determine the best values to use for any
given situation. Use the component tables as a starting
point, but be aware that deviation from these values is not
out of the ordinary.
External Divide
DIV SEL (pin 8) controls the use of the internal divider. When
high, the internal divider is enabled and EXT DIV (pin 13)
outputs the CLK out divided by N. This is the signal to which
the horizontal sync input will lock. When divide select is low,
the internal divider output is disabled, and external divide
becomes an input from an external divider, so that a divisor
other than one of the 8 pre-programmed internal divisors can
be used.
Normal Mode
Normal mode is enabled by pulling COAST (pin 9) low
(below 1/3*VCC). If HSYNC and CLK ÷ N have any phase or
frequency difference, an error signal is generated and sent
to the charge pump. The charge pump will either force
current into or out of the filter capacitor in an attempt to
modulate the VCO frequency. Modulation will continue until
the phase and frequency of CLK ÷ N exactly match the
HSYNC input. When the phase and frequency match (with
some offset in phase that is a function of the VCO
characteristics), the error signal goes to zero, lock detect no
longer pulses high, and the charge pump enters a high
impedance state. The clock is now locked to the HSYNC
input. As long as phase and frequency differences remain
small, the PLL can adjust the VCO to remain locked and lock
detect remains low.
possible. VCO frequency will drift as charge leaks from the
filter capacitor, and the voltage changes the VCO operating
point. Coast mode is intended to be used when noise or
signal degradation result in loss of horizontal sync for many
cycles. The phase detector will not attempt to adjust to the
resultant loss of signal so that when horizontal sync returns,
sync lock can be re-established quickly. However, if much
VCO drift has occurred, it may take as long to re-lock as
when restarting.
Lock Detect
Lock detect (pin 12) will go low when lock is established. Any
DC current path from charge pump out will skew EXT DIV
relative to HSYNC in, tending to offset or add to the 110ns
internal delay, depending on which way the extra current is
flowing. This offset is called static phase error, and is always
present in any PLL system. If, when the part stabilizes in a
locked mode, lock detect is not low, adding or subtracting
from the loop filter series resistor R2 will change this static
phase error to allow LDET to go low while in lock. The goal is
to put the rising edge of EXT DIV in sync with the falling
edge of HSYNC + 110ns. (See timing diagrams.) Increasing
R2 decreases phase error, while decreasing R2 increases
phase error. (Phase error is positive when EXT DIV lags
HSYNC.) The resistance needed will depend on VCO design
or VCXO module selection.
Applications Information
Choosing External Components
1. To choose LC VCO components, first pick the desired
operating frequency. For our example we will use
14.31818MHz, with an HSYNC frequency of 15.734kHz.
2. Choose a reasonable inductor value (10–20µH works
well). We choose 15µH.
Fast Lock Mode
Fast Lock mode is enabled by either allowing coast to float,
or pulling it to mid supply (between 1/3 and 2/3*VCC). In this
mode, lock is achieved much faster than in normal mode, but
the clock divisor is modified on the fly to achieve this. If the
phase detector detects an error of enough magnitude, the
clock is either inhibited or reset to attempt a “fast” lock of the
signals.
Forcing the clock to be synchronized to the HSYNC input this
way allows a lock in approximately 2 H-cycles, but the clock
spacing will not be regular during this time. Once the near
lock condition is attained, charge pump output should be
very close to its lock-on value and placing the device into
normal mode should result in a normal lock very quickly.
Fast Lock mode is intended to be used where HSYNC
becomes irregular, until a stable signal is again obtained.
Coast Mode
Coast mode is enabled by pulling COAST (pin 9) high
(above 2/3*VCC). In coast mode the internal phase detector
is disabled and filter out remains in high impedance mode to
keep filter out voltage and VCO frequency as constant a
8
3. Calculate CT needed to produce FOSC.
1
F OSC = ----------------------2π LC T
1
1
C T = --------------------- = --------------------------------------------------------------------- = 8.2pF
2 2
2
2
4π ( 14.318e6 ) ( 15e – 6 )
4π F L
4. From the varactor data sheet find CV @ 2.5V, the desired
lock voltage. CV = 23pF for our SMV1204-12, for
example.
5. C2 should be about 10CV, so we choose C2 = 220pF for
our example.
6. Calculate C1. Since:
C1 C2 CV
C T = --------------------------------------------------------------------------( C 1 C 2 ) + ( C 1 C V ) + ( C 2 C V )′
then:
C2 CT CV
C 1 = ------------------------------------------------------------------------( C2 CV ) –( C2 CT ) – ( CT CV ) ′
FN7174.2
July 25, 2005
EL4584
For our example, C1 = 14pF. (A trim cap may be used for
fine tuning.) Examples for each frequency using the internal
divider follow.
Typical Application
Horizontal genlock provides clock for an analog to digital
converter, digitizing analog video.
XTAL VCO COMPONENT VALUES (APPROXIMATE)
FREQUENCY
(MHz)
R1
(kΩ)
C1
(pF)
C2
(µF)
13.301
300
15
0.001
13.5
300
15
0.001
14.75
300
15
0.001
17.734
300
15
0.001
10.738
300
15
0.001
12.273
300
15
0.001
14.318
300
15
0.001
The above oscillators are arranged as Colpitts oscillators,
and the structure is redrawn here to emphasize the split
capacitance used in a Colpitts oscillator. It should be noted
that this oscillator configuration is just one of literally
hundreds possible, and the configuration shown here does
not necessarily represent the best solution for all
applications. Crystal manufacturers are very informative
sources on the design and use of oscillators in a wide variety
of applications, and the reader is encouraged to become
familiar with them.
FIGURE 4. TYPICAL LC VCO
LC VCO COMPONENT VALUES (APPROXIMATE) (NOTE)
FREQUENCY
(MHZ)
L1
(µH)
C1
(pF)
C2
(pF)
13.301
15
18
220
13.5
15
17
220
14.75
12
18
220
17.734
12
10
220
10.738
22
20
220
12.273
18
17
220
14.318
15
14
220
NOTE: Use shielded inductors for optimum performance.
FIGURE 6. COLPITTS OSCILLATOR
C1 is to adjust the center frequency, C2 DC isolates the
control from the oscillator, and V1 is the primary control
device. C2 should be much larger than CV so that V1 has
maximum modulation capability. The frequency of oscillation
is given by:
1
F = ------------------------12π LCT
C1 C2 CV
C T = ------------------------------------------------------------------------( C1 C2 ) + ( C1 CV ) + ( C2 CV )
Choosing Loop Filter Components
The PLL, VCO, and loop filter can be described as:
FIGURE 5. TYPICAL XTAL VCO
9
FN7174.2
July 25, 2005
EL4584
Where:
Kd = phase detector gain in A/rad
F(s) = loop filter impedance in V/A
KVCO = VCO gain in rad/s/V
N = internal or external divisor
It can be shown that for the loop filter shown below:
C3
K d K VCO
2Nξω n
C 3 = ------------------------, C 4 = -------, R 3 = ----------------------2
10
K d K VCO
Nω
n
Where ϖn = loop filter bandwidth, and ζ = loop filter damping
factor.
1. Kd = 300µA/2πrad = 4.77e-5A/rad for the EL4584.
2. The loop bandwidth should be about HSYNC
frequency/20, and the damping ratio should be 1 for
optimum performance. For our example,
ϖn = 15.734kHz/20 = 787Hz≈5000rad/S.
3. N = 910 from table 1.
VCOfrequency
14.31818M
N = ---------------------------------------------------------- = ------------------------------ = 910
H – SYNCfrequency
15.73426k
4. KVCO represents how much the VCO frequency changes
for each volt applied at the control pin. It is assumed (but
probably is not) linear about the lock point (2.5V). Its
value depends on the VCO configuration and the varactor
transfer function CV = F(VC), where VC is the reverse
bias control voltage, and CV is varactor capacitance.
Since F(VC) is nonlinear, it is probably best to build the
VCO and measure KVCO about 2.5V. The results of one
such measurement are shown below. The slope of the
curve is determined by linear regression techniques and
equals KVCO. For our example, KVCO = 6.05 Mrad/S/V.
K d K VCO
( 4.77e – 5 ) ( 6.05e6 )
- = ------------------------------------------------------ = 0.01µF
C 3 = ----------------------2
2
( 910 ) ( 5000 )
Nω
n
C
C 4 = ------3- = 0.0001µF
10
2Nζω n
( 2 ) ( 910 ) ( 1 ) ( 5000 )
- = ------------------------------------------------------ = 31.5kΩ
R 3 = ----------------------( 4.77e – 5 ) ( 6.05e6 )
K d K VCO
increases, Tθ decreases. For LDET to be low at lock,
|Tθ| < 50 ns. C4 is used mainly to attenuate high
frequency noise from the charge pump.
Lock Time
Let = R3C3. As T increases, damping increases, but so does
lock time. Decreasing T decreases damping and speeds up
loop response, but increases overshoot and thus increases
the number of hunting oscillations before lock. Critical
damping (ζ = 1) occurs at minimum lock time. Because
decreased damping also decreases loop stability, it is
sometimes desirable to design slightly overdamped (ζ > 1),
trading lock time for increased stability.
FIGURE 7. TYPICAL LOOP FILTER
FOSC vs VC, LC VCO
LC LOOP FILTER COMPONENTS (APPROXIMATE)
5. Now we can solve for C3, C4, and R3.
We choose R3 = 30kΩ for convenience.
FREQUENCY
(MHZ)
R2
(kΩ)
R3
(kΩ)
C3
(µF)
C4
(µF)
13.301
100
30
0.01
0.001
13.5
100
30
0.01
0.001
14.75
100
33
0.01
0.001
17.734
100
39
0.01
0.001
10.738
100
22
0.01
0.001
12.273
100
27
0.01
0.001
14.318
100
30
0.01
0.001
6. Notice R2 has little effect on the loop filter design. R2
should be large, around 100k, and can be adjusted to
compensate for any static phase error Tθ at lock, but if
made too large, will slow loop response. If R2 is made
smaller, Tθ (see timing diagrams) increases, and if R2
10
FN7174.2
July 25, 2005
EL4584
XTAL LOOP FILTER COMPONENTS (APPROXIMATE)
FREQUENCY
(MHz)
R2
(kΩ)
R3
(MΩ)
C3
(pF)
C4
(pF)
13.301
100
4.3
68
6.8
13.5
100
4.3
68
6.8
14.75
100
4.3
68
6.8
17.734
100
4.3
68
6.8
10.738
100
4.3
68
6.8
12.273
100
4.3
68
6.8
14.318
100
4.3
68
6.8
PCB Layout Considerations
It is highly recommended that power and ground planes be
used in layout. The oscillator and filter sections constitute a
feedback loop and thus care must be taken to avoid any
feedback signal influencing the oscillator except at the
control input. The entire oscillator/filter section should be
surrounded by copper ground to prevent unwanted
influences from nearby signals. Use separate paths for
11
analog and digital supplies, keeping the analog (oscillator
section) as short and free from spurious signals as possible.
Careful attention must be paid to correct bypassing. Keep
lead lengths short and place bypass caps as close to the
supply pins as possible. If laying out a PCB to use discrete
components for the VCO section, care must be taken to
avoid parasitic capacitance at the OSC pins 3 and 5, and
FILTER out (pin 7). Remove ground and power plane copper
above and below these traces to avoid making a capacitive
connection to them. It is also recommended to enclose the
oscillator section within a shielded cage to reduce external
influences on the VCO, as they tend to be very sensitive to
“handwaving” influences, the LC variety being more
sensitive than crystal controlled oscillators. In general, the
higher the operating frequency, the more important these
considerations are. Self contained VCXO or VCO modules
are already mounted in a shielding cage and therefore do
not require as much consideration in layout. Many crystal
manufacturers publish informative literature regarding use
and layout of oscillators which should be helpful.
Demo Board
FN7174.2
July 25, 2005
EL4584
The VCO and loop filter section of the EL4583/4/5 demo
board can be implemented in the following configurations:
(1) VCXO
(3) LC TANK
(2) XTAL
Component Sources
Inductors
El Monte, CA 91731
(818) 443-2121
Varactors
• Dale Electronics
E. Highway 50
PO Box 180
Yankton, SD 57078-0180
(605) 665-9301
Crystals, VCXO, VCO Modules
• Connor-Winfield
2111 Comprehensive Drive
Aurora, IL 60606
(708) 851-4722
• Piezo Systems
100 K Street
PO Box 619
Carlisle, PA 17013
(717) 249-2151
• Sky Works Solutions Inc.
20 Sylvan Road
Woburn, MA 01801
(781) 376-3000
www.skyworksinc.com
• Motorola Semiconductor Products
2100 E. Elliot
Tempe, AZ 85284
(602) 244-6900
Note: These sources are provided for information purposes
only. No endorsement of these companies is implied by this
listing.
• Reeves-Hoffman
400 West North Street
Carlisle, PA 17013
(717) 243-5929
• SaRonix
151 Laura Lane
Palo Alto, CA 94043
(415) 856-6900
• Standard Crystal
9940 Baldwin Place
All Intersil U.S. products are manufactured, assembled and tested utilizing ISO9000 quality systems.
Intersil Corporation’s quality certifications can be viewed at www.intersil.com/design/quality
Intersil products are sold by description only. Intersil Corporation reserves the right to make changes in circuit design, software and/or specifications at any time without
notice. Accordingly, the reader is cautioned to verify that data sheets are current before placing orders. Information furnished by Intersil is believed to be accurate and
reliable. However, no responsibility is assumed by Intersil or its subsidiaries for its use; nor for any infringements of patents or other rights of third parties which may result
from its use. No license is granted by implication or otherwise under any patent or patent rights of Intersil or its subsidiaries.
For information regarding Intersil Corporation and its products, see www.intersil.com
12
FN7174.2
July 25, 2005