ENERGY STAR Data Sheet

ENERGY STAR ® Power and Performance Data Sheet
Express5800/R110f-1E
System Characteristics
Form Factor
1 Socket Server
Available Processor Sockets
1
Available DIMM Slots / Max Memory Capacity
4slots / 32GB max.
ECC and/or Fully Buffered DIMMs
Yes
Available Expansion Slots
1 PCI-E 3.0, 1 PCI-E 2.0
Minimum and Maximum # of Hard Drives
0 to 8
Redundant Power Supply Capable?
Yes
Power Supply Make and Model
Delta Electronics, Inc. DPS-500WB X
Power Supply Output Rating* (watts)
450W
Minimum and Maximum # of Power Supplies
2
Input Power Range (AC or DC)
100-200VAC
Power Supply Efficiency at Specified Loadings*
89.54@20%, 92.36@50%, 91.44@100%
Power Supply Power Factor at Specified Loadings*
0.97@20%, 0.99@50%, 1.00@100%
Operating Systems Supported
Microsoft Windows Server 2008 R2 Standard etc.
Installed Operating System for Testing
Microsoft Windows Server 2008 R2 Standard
* Note: Power supply information is for a single power supply only
System Configurations
Configuration ID
Processor Information
Memory Information
Internal Storage
I/O Devices
Power Supply Number and Redundancy Configuration
Management Controller or Service Processor Installed?
Other Hardware Features / Accessories
Power Data
Idle Category (1S and 2S only)
ENERGY STAR Idle Power Allowance (1S and 2S only)
Minimum
Typical
Maximum
N8100-2019Y
N8100-2021Y
N8100-2023Y
Intel Xeon E3-1220 v3
3.1GHz
DDR3-1600
2GB x1
Intel Xeon E3-1230v3
3.3GHz
DDR3-1600
8GB x2
Intel Xeon E3-1270 v3
3.5GHz
DDR3-1600
8GB x4
SATA 6Gbps 7200rpm
250GB x1
SAS 6Gbps 15000rpm
300GB x3
SAS 6Gbps 15000rpm
300GB x8
None
SAS Raid Card x1
SAS Raid Card x1
SAS HBA card x1
Ethernet card x2
DPS-500WB X
450W x2
DPS-500WB X
450W x2
DPS-500WB X
450W x2
Yes
Yes
Yes
None
None
None
Minimum
Typical
Maximum
Category B: Managed Single Installed Processor (1P) Servers
85
157
237
Measured Idle Power (watts)
39.5
75.1
117.8
Power at Full Load* (watts)
70.9
115.6
164.4
Benchmark / Method Used for Full Load Test
Use SiSoftware Sandra Engineer Standard 210.SP1a
230V / 60Hz
Test Voltage and Frequency for Idle and Full Load Test
Range of Total Estimated Energy Usage ** (kWh/year)
692 to 1242
1316 to 2025
2064 to 2880
Link to Detailed Power Calculator (if available)
* Note: Full load power represents the sustained, average power at 100% load of the given workload, and does not necessarily represent the absolute peak power or the
highest average, sustained power possible for other workloads.
** Note: Estimated kWh/year gives the absolute range of energy use a user could expect from continuous operation (24x7x365) and ranges from 100% Idle usage to 100%
full load operation. The calculation also includes typical data center overhead at a ratio
Benchmark #1
Power and Performance for Benchmark #1
Benchmark Used and Type of Workload
Typical
Maximum
SiSoftware Sandra Engineer Standard 210.SP1a
70.9
115.6
164.4
15.53Mpixel/s
28.42Mpixel/s
30.00Mpixel/s
Power Performance Ratio (perf score/avg. power)
0.22
0.25
0.18
Link to Full Benchmark Report (Where Available)
N/A
N/A
N/A
Power and Performance for Benchmark #2 (optional)
Minimum
Typical
Maximum
Benchmark #2
Avg. Power Measured During Benchmark Run
Minimum
Benchmark Performance Score
Benchmark Used and Type of Workload
Avg. Power Measured During Benchmark Run
Benchmark Performance Score
Power Performance Ratio (perf score/avg. power)
Link to Full Benchmark Report (Where Available)
ENERGY STAR Power and Performance Data Sheet
Express5800/R110f-1E
Page 2 of 3
Power Saving Features
Processor Dynamic Voltage and Frequency Scaling
Processor or Core Reduced Power States
Power Capping
Variable Speed Fan Control Based on Power or Thermal Readings
Low Power Memory States
Low Power I/O States
Liquid Cooling Capability
Enabled on
Shipment
End-User Enabling
Required
Yes
Yes
No
Yes
No
No
No
No
No
Yes
No
No
No
No
Other1:
Other2:
Other3:
Other4:
Power and Temperature Measurement and Reporting
Input Power Available & Accuracy?
Yes, +/- 5%
Input Air Temp Available & Accuracy?
Yes, +/- 2 degree C
Processor Utilization Available?
Yes
Other Data Measurements Available & Accuracy?
Compatible Protocols for Data Collection
IPMI
Averaging method and time period
Non Averaging, 1 sec. interval sampling
Thermal Information *
Minimum
Typical
Maximum
70.9
115.6
164.4
Delta Temperature at Exhaust at Peak Temp. (˚C)
2.1
4.2
4.8
Airflow at Maximum Fan Speed (CFM) at Peak Temp.
38.2
52.7
56.4
Airflow at Nominal Fan Speed (CFM) at Nominal Temp.
25.0
38.7
33.3
Total Power Dissipation (watts)
* References: ASHRAE Extended Environmental Envelope Final August 1, 2008
Thermal Guidelines for Data Processing Environments, ASHRAE, 2004, ISBN 1-931862-43-5
Peak temperature is defined as 35 ˚C, Nominal Tempera
Notes
1. SPECpower_ssj2008 is a registered trademark of the Standard Performance Evaluation Corporation (SPEC). Benchmark results stated above reflect results published on
XX/XX/XX. For the latest SPECpower_ssj2008 benchmark results, visit http://www.spec.org
ENERGY STAR Qualified Configurations
Include specific information on ENERGY STAR Qualified SKUs or configurations
Qualified Configuration ID: N8100-2019Y, N8100-2021Y, N8100-2023Y, N8100-1989Y, N8100-1991Y, N81001993Y, N8100-1998F/2000F (with E3-1220v3 or 1230v3 or 1270v3)
ENERGY STAR Power and Performance Data Sheet
Express5800/R110f-1E
Page 3 of 3
ENERGY STAR Qualified Configurations (Continued)
Include specific information on ENERGY STAR Qualified SKUs or configurations