® ENERGY STAR Power and Performance Data Sheet Express5800/GT110e-S(Air cooling) System Characteristics Form Factor 1 socket slim pedestal server Available Processor Sockets 1 Available DIMM Slots / Max Memory Capacity 4slots / 32GB max. ECC and/or Fully Buffered DIMMs Yes Available Expansion Slots 3 PCI-E 2.0, 1 PCI Minimum and Maximum # of Hard Drives 0 to 5 Redundant Power Supply Capable? No Power Supply Make and Model LeadYear TG10-0250-01 Power Supply Output Rating* (watts) 250W Minimum and Maximum # of Power Supplies 1 Input Power Range (AC or DC) 100-240VAC Power Supply Efficiency at Specified Loadings* 85.0%@20%, 88.4%@50%, 85.9%@100% Power Supply Power Factor at Specified Loadings* 0.970@20%, 0.990@50%, 0.999@100% Operating Systems Supported Microsoft Windows Server 2008 R2 Standard etc. Installed Operating System for Testing Microsoft Windows Server 2008 R2 Standard * Note: Power supply information is for a single power supply only System Configurations Minimum Typical Maximum N8100-1887Y N8100-1887Y N8100-1887Y Intel Xeon E3-1220v2 3.10GHz x1 DDR3-1600 2GB x1 Intel Xeon E3-1220v2 3.10GHz x1 DDR3-1600 8GB x2 Intel Xeon E3-1220v2 3.10GHz x1 DDR3-1600 8GB x4 SATA 6Gbps 7200rpm 250GB x1 SAS 6Gbps 10000rpm 900GB x2 None SAS Raid Card x1 Power Supply Number and Redundancy Configuration TG10-0250-01 250W x1 TG10-0250-01 250W x1 SAS 6Gbps 10000rpm 900GB x5 SAS Raid Card x1 Ethernet card x1 TG10-0250-01 250W x1 Management Controller or Service Processor Installed? Yes Yes Yes Minimum Typical Maximum Configuration ID Processor Information Memory Information Internal Storage I/O Devices Other Hardware Features / Accessories Power Data Idle Category (1S and 2S only) Category B: Managed Single Installed Processor (1P) Servers ENERGY STAR Idle Power Allowance (1S and 2S only) 65.0 133.0 Measured Idle Power (watts) 28.2 50.7 77.7 Power at Full Load* (watts) 51.0 75.1 102.8 Benchmark / Method Used for Full Load Test Use SiSoftware Sandra Engineer (.NET Multi-Media) 230V / 60Hz Test Voltage and Frequency for Idle and Full Load Test Range of Total Estimated Energy Usage ** (kWh/year) 205.0 494 to 894 0,888 to 1,316 1,361 to 1,801 Link to Detailed Power Calculator (if available) * Note: Full load power represents the sustained, average power at 100% load of the given workload, and does not necessarily represent the absolute peak power or the highest average, sustained power possible for other workloads. ** Note: Estimated kWh/year gives the absolute range of energy use a user could expect from continuous operation (24x7x365) and ranges from 100% Idle usage to 100% full load operation. The calculation also includes typical data center overhead at a ratio Benchmark #1 Power and Performance for Benchmark #1 Minimum Maximum 51.0 75.1 102.8 15.12Mpixel/s 15.30Mpixel/s 15.23Mpixel/s Power Performance Ratio (perf score/avg. power) 0.30 0.20 0.15 Link to Full Benchmark Report (Where Available) N/A N/A N/A Power and Performance for Benchmark #2 (optional) Minimum Typical Maximum Benchmark #2 Avg. Power Measured During Benchmark Run Typical SiSoftware Sandra Engineer (.NET Multi-Media) Benchmark Used and Type of Workload Benchmark Performance Score Benchmark Used and Type of Workload Avg. Power Measured During Benchmark Run Benchmark Performance Score Power Performance Ratio (perf score/avg. power) Link to Full Benchmark Report (Where Available) ENERGY STAR Power and Performance Data Sheet Express5800/GT110e-S(Air cooling) Page 2 of 3 Power Saving Features Processor Dynamic Voltage and Frequency Scaling Processor or Core Reduced Power States Power Capping Variable Speed Fan Control Based on Power or Thermal Readings Low Power Memory States Low Power I/O States Liquid Cooling Capability Enabled on Shipment End-User Enabling Required Yes Yes No Yes No No No No No Yes No No No No Other1: Other2: Other3: Other4: Power and Temperature Measurement and Reporting Input Power Available & Accuracy? Yes, +/- 5% Input Air Temp Available & Accuracy? Yes, +/- 2 degree C Processor Utilization Available? Yes Other Data Measurements Available & Accuracy? Compatible Protocols for Data Collection IPMI Averaging method and time period Non Averaging, 1 sec. interval sampling Thermal Information * Minimum Typical Maximum 51.0 75.1 102.8 Delta Temperature at Exhaust at Peak Temp. (˚C) 6.5 5.3 6.8 Airflow at Maximum Fan Speed (CFM) at Peak Temp. 11.3 11.8 12.5 Airflow at Nominal Fan Speed (CFM) at Nominal Temp. 10.6 10.8 11.7 Total Power Dissipation (watts) * References: ASHRAE Extended Environmental Envelope Final August 1, 2008 Thermal Guidelines for Data Processing Environments, ASHRAE, 2004, ISBN 1-931862-43-5 Peak temperature is defined as 35 ˚C, Nominal Tempera Notes 1. SPECpower_ssj2008 is a registered trademark of the Standard Performance Evaluation Corporation (SPEC). Benchmark results stated above reflect results published on XX/XX/XX. For the latest SPECpower_ssj2008 benchmark results, visit http://www.spec.org ENERGY STAR Qualified Configurations Include specific information on ENERGY STAR Qualified SKUs or configurations Qualified Configuration ID: N8100-1885Y/1887Y, N8100-1891F/1892F/1891CF/1892CF(with E3-1220v2) ENERGY STAR Power and Performance Data Sheet Express5800/GT110e-S(Air cooling) Page 3 of 3 ENERGY STAR Qualified Configurations (Continued) Include specific information on ENERGY STAR Qualified SKUs or configurations