® ENERGY STAR Power and Performance Data Sheet Express5800/R110d-1E [Xeon E3-1220, E3-1270 model] System Characteristics Form Factor 1U Rack Available Processor Sockets 1 Available DIMM Slots / Max Memory Capacity 4/32GB ECC and/or Fully Buffered DIMMs Yes Available Expansion Slots 2 PCI-E 2.0 Minimum and Maximum # of Hard Drives 0 to 6 Redundant Power Supply Capable? No Power Supply Make and Model Delta DPS-400AB-12 A Power Supply Output Rating* (watts) 400W Minimum and Maximum # of Power Supplies 1 Input Power Range (AC or DC) 100-240VAC Power Supply Efficiency at Specified Loadings* 88.2%@20%, 91.0%@50%, 89.4%@100% Power Supply Power Factor at Specified Loadings* 0.990@20%, 0.999@50%, 0.999@100% Operating Systems Supported Microsoft Windows Server 2003 R2 Standard Microsoft Windows Server 2008 Standard/Enterprise Microsoft Windows Server 2008 R2 Standard/Enterprise Red Hat Enterprise Linux 5.6 Red Hat Enterprise Linux 6.1 Installed Operating System for Testing Microsoft Windows Server 2008 R2 Standard * Note: Power supply information is for a single power supply only System Configurations Configuration ID Processor Information Minimum Typical Maximum N8100-1764 N8100-1764 N8100-1765 1, Intel Xeon E3-1270 1, Intel Xeon E3-1220 1, Intel Xeon E3-1220 Memory Information 1, 1GB 2, 8GB 4, 8GB Internal Storage 1, HDD 2, HDD 6, HDD 2, onboard 1Gb ports 2, onboard 1Gb ports 1, Non Redundancy 1, Non Redundancy 2, onboard 1Gb ports + 1, 10Gb(2ch) NIC 1, Non Redundancy Yes Yes Yes Minimum Typical Maximum I/O Devices Power Supply Number and Redundancy Configuration Management Controller or Service Processor Installed? Other Hardware Features / Accessories Power Data Idle Category (1S and 2S only) Category B: Managed Single Installed Processor (1P) Servers ENERGY STAR Idle Power Allowance (1S and 2S only) 65.0 97.0 Measured Idle Power (watts) 22.68 59.77 94.83 Power at Full Load* (watts) 85.14 109.00 171.10 Benchmark / Method Used for Full Load Test SiSoftware Sandra Engineer 2010 / .NET Multi-Media 230V / 60Hz Test Voltage and Frequency for Idle and Full Load Test Range of Total Estimated Energy Usage ** (kWh/year) 177.0 0,397 to 1,492 1,047 to 1,910 1,661 to 2,998 Link to Detailed Power Calculator (if available) * Note: Full load power represents the sustained, average power at 100% load of the given workload, and does not necessarily represent the absolute peak power or the highest average, sustained power possible for other workloads. ** Note: Estimated kWh/year gives the absolute range of energy use a user could expect from continuous operation (24x7x365) and ranges from 100% Idle usage to 100% full load operation. The calculation also includes typical data center overhead at a ratio of 1 watt of overhead to every 1 watt of IT load (corresponding to a PUE of 2.0). Closer approximations may be found by using established power calculators and specific information about the intended operating environment (e.g., average time at Idle, data center PUE, etc.). Benchmark #1 Power and Performance for Benchmark #1 Benchmark Used and Type of Workload Typical Maximum SiSoftware Sandra Engineer 2010 / .NET Multi-Media Avg. Power Measured During Benchmark Run 85.14 109.00 Benchmark Performance Score 27.00 27.00 14.74 0.31712 0.24771 0.08615 Minimum Typical Maximum Power Performance Ratio (perf score/avg. power) 171.10 Link to Full Benchmark Report (Where Available) Power and Performance for Benchmark #2 (optional) Benchmark #2 Minimum Benchmark Used and Type of Workload Avg. Power Measured During Benchmark Run Benchmark Performance Score Power Performance Ratio (perf score/avg. power) Link to Full Benchmark Report (Where Available) ENERGY STAR Power and Performance Data Sheet Express5800/R110d-1E [Xeon E3-1220, E3-1270 model] Page 2 of 3 Power Saving Features Processor Dynamic Voltage and Frequency Scaling Processor or Core Reduced Power States Power Capping Variable Speed Fan Control Based on Power or Thermal Readings Low Power Memory States Low Power I/O States Liquid Cooling Capability Enabled on Shipment End-User Enabling Required Yes Yes No Yes No No No No No Yes No No No No Other1: Other2: Other3: Other4: Power and Temperature Measurement and Reporting Input Power Available & Accuracy? Yes, +/- 5% Input Air Temp Available & Accuracy? Yes, +/- 2 degree C Processor Utilization Available? Yes Other Data Measurements Available & Accuracy? Compatible Protocols for Data Collection IPMI Averaging method and time period Non Averaging, 1 sec. interval sampling Thermal Information * Minimum Typical Maximum Total Power Dissipation (watts) 85.14 109.00 171.10 Delta Temperature at Exhaust at Peak Temp. (˚C) 36.2 37.1 39.2 Airflow at Maximum Fan Speed (CFM) at Peak Temp. 17.4 17.0 21.9 Airflow at Nominal Fan Speed (CFM) at Nominal Temp. 10.2 11.1 11.5 * References: ASHRAE Extended Environmental Envelope Final August 1, 2008 Thermal Guidelines for Data Processing Environments, ASHRAE, 2004, ISBN 1-931862-43-5 Peak temperature is defined as 35 ˚C, Nominal Temperature is defined as 18 - 27 ˚C Notes 1. SPECpower_ssj2008 is a registered trademark of the Standard Performance Evaluation Corporation (SPEC). Benchmark results stated above reflect results published on XX/XX/XX. For the latest SPECpower_ssj2008 benchmark results, visit http://www.spec.org/power_ssj2008. ENERGY STAR Qualified Configurations Include specific information on ENERGY STAR Qualified SKUs or configurations ENERGY STAR Power and Performance Data Sheet Express5800/R110d-1E [Xeon E3-1220, E3-1270 model] Page 3 of 3 ENERGY STAR Qualified Configurations (Continued) Include specific information on ENERGY STAR Qualified SKUs or configurations