ENERGY STAR Data Sheet

®
ENERGY STAR Power and Performance Data Sheet
Express5800/R110d-1E [Xeon E3-1220, E3-1270 model]
System Characteristics
Form Factor
1U Rack
Available Processor Sockets
1
Available DIMM Slots / Max Memory Capacity
4/32GB
ECC and/or Fully Buffered DIMMs
Yes
Available Expansion Slots
2 PCI-E 2.0
Minimum and Maximum # of Hard Drives
0 to 6
Redundant Power Supply Capable?
No
Power Supply Make and Model
Delta DPS-400AB-12 A
Power Supply Output Rating* (watts)
400W
Minimum and Maximum # of Power Supplies
1
Input Power Range (AC or DC)
100-240VAC
Power Supply Efficiency at Specified Loadings*
88.2%@20%, 91.0%@50%, 89.4%@100%
Power Supply Power Factor at Specified Loadings*
0.990@20%, 0.999@50%, 0.999@100%
Operating Systems Supported
Microsoft Windows Server 2003 R2 Standard
Microsoft Windows Server 2008 Standard/Enterprise
Microsoft Windows Server 2008 R2 Standard/Enterprise
Red Hat Enterprise Linux 5.6
Red Hat Enterprise Linux 6.1
Installed Operating System for Testing
Microsoft Windows Server 2008 R2 Standard
* Note: Power supply information is for a single power supply only
System Configurations
Configuration ID
Processor Information
Minimum
Typical
Maximum
N8100-1764
N8100-1764
N8100-1765
1, Intel Xeon E3-1270
1, Intel Xeon E3-1220
1, Intel Xeon E3-1220
Memory Information
1, 1GB
2, 8GB
4, 8GB
Internal Storage
1, HDD
2, HDD
6, HDD
2, onboard 1Gb ports
2, onboard 1Gb ports
1, Non Redundancy
1, Non Redundancy
2, onboard 1Gb ports
+ 1, 10Gb(2ch) NIC
1, Non Redundancy
Yes
Yes
Yes
Minimum
Typical
Maximum
I/O Devices
Power Supply Number and Redundancy Configuration
Management Controller or Service Processor Installed?
Other Hardware Features / Accessories
Power Data
Idle Category (1S and 2S only)
Category B: Managed Single Installed Processor (1P) Servers
ENERGY STAR Idle Power Allowance (1S and 2S only)
65.0
97.0
Measured Idle Power (watts)
22.68
59.77
94.83
Power at Full Load* (watts)
85.14
109.00
171.10
Benchmark / Method Used for Full Load Test
SiSoftware Sandra Engineer 2010 / .NET Multi-Media
230V / 60Hz
Test Voltage and Frequency for Idle and Full Load Test
Range of Total Estimated Energy Usage ** (kWh/year)
177.0
0,397 to 1,492
1,047 to 1,910
1,661 to 2,998
Link to Detailed Power Calculator (if available)
* Note: Full load power represents the sustained, average power at 100% load of the given workload, and does not necessarily represent the absolute peak power or the
highest average, sustained power possible for other workloads.
** Note: Estimated kWh/year gives the absolute range of energy use a user could expect from continuous operation (24x7x365) and ranges from 100% Idle usage to 100%
full load operation. The calculation also includes typical data center overhead at a ratio of 1 watt of overhead to every 1 watt of IT load (corresponding to a PUE of 2.0).
Closer approximations may be found by using established power calculators and specific information about the intended operating environment (e.g., average time at Idle,
data center PUE, etc.).
Benchmark #1
Power and Performance for Benchmark #1
Benchmark Used and Type of Workload
Typical
Maximum
SiSoftware Sandra Engineer 2010 / .NET Multi-Media
Avg. Power Measured During Benchmark Run
85.14
109.00
Benchmark Performance Score
27.00
27.00
14.74
0.31712
0.24771
0.08615
Minimum
Typical
Maximum
Power Performance Ratio (perf score/avg. power)
171.10
Link to Full Benchmark Report (Where Available)
Power and Performance for Benchmark #2 (optional)
Benchmark #2
Minimum
Benchmark Used and Type of Workload
Avg. Power Measured During Benchmark Run
Benchmark Performance Score
Power Performance Ratio (perf score/avg. power)
Link to Full Benchmark Report (Where Available)
ENERGY STAR Power and Performance Data Sheet
Express5800/R110d-1E [Xeon E3-1220, E3-1270 model]
Page 2 of 3
Power Saving Features
Processor Dynamic Voltage and Frequency Scaling
Processor or Core Reduced Power States
Power Capping
Variable Speed Fan Control Based on Power or Thermal Readings
Low Power Memory States
Low Power I/O States
Liquid Cooling Capability
Enabled on
Shipment
End-User Enabling
Required
Yes
Yes
No
Yes
No
No
No
No
No
Yes
No
No
No
No
Other1:
Other2:
Other3:
Other4:
Power and Temperature Measurement and Reporting
Input Power Available & Accuracy?
Yes, +/- 5%
Input Air Temp Available & Accuracy?
Yes, +/- 2 degree C
Processor Utilization Available?
Yes
Other Data Measurements Available & Accuracy?
Compatible Protocols for Data Collection
IPMI
Averaging method and time period
Non Averaging, 1 sec. interval sampling
Thermal Information *
Minimum
Typical
Maximum
Total Power Dissipation (watts)
85.14
109.00
171.10
Delta Temperature at Exhaust at Peak Temp. (˚C)
36.2
37.1
39.2
Airflow at Maximum Fan Speed (CFM) at Peak Temp.
17.4
17.0
21.9
Airflow at Nominal Fan Speed (CFM) at Nominal Temp.
10.2
11.1
11.5
* References: ASHRAE Extended Environmental Envelope Final August 1, 2008
Thermal Guidelines for Data Processing Environments, ASHRAE, 2004, ISBN 1-931862-43-5
Peak temperature is defined as 35 ˚C, Nominal Temperature is defined as 18 - 27 ˚C
Notes
1. SPECpower_ssj2008 is a registered trademark of the Standard Performance Evaluation Corporation (SPEC). Benchmark results stated above reflect results published on XX/XX/XX.
For the latest SPECpower_ssj2008 benchmark results, visit http://www.spec.org/power_ssj2008.
ENERGY STAR Qualified Configurations
Include specific information on ENERGY STAR Qualified SKUs or configurations
ENERGY STAR Power and Performance Data Sheet
Express5800/R110d-1E [Xeon E3-1220, E3-1270 model]
Page 3 of 3
ENERGY STAR Qualified Configurations (Continued)
Include specific information on ENERGY STAR Qualified SKUs or configurations